Methods Inf Med 1997; 36(04/05): 254-256
DOI: 10.1055/s-0038-1636876
Original Article
Schattauer GmbH

Spatial Fluctuation of Regional Myocardial Blood Flows

T. Matsumoto
1   Department of Medical Engineering and Systems Cardiology, Kawasaki Medical School, Kurashiki, Okayama, Japan
,
J. Ebata
1   Department of Medical Engineering and Systems Cardiology, Kawasaki Medical School, Kurashiki, Okayama, Japan
,
K. Tsujioka
1   Department of Medical Engineering and Systems Cardiology, Kawasaki Medical School, Kurashiki, Okayama, Japan
,
Y. Ogasawara
1   Department of Medical Engineering and Systems Cardiology, Kawasaki Medical School, Kurashiki, Okayama, Japan
,
F. Kajiya
1   Department of Medical Engineering and Systems Cardiology, Kawasaki Medical School, Kurashiki, Okayama, Japan
› Author Affiliations
Further Information

Publication History

Publication Date:
19 February 2018 (online)

Abstract:

Digital radiography (100 pixels/mm2) combined with the technique of 3H-labeled desmethylimipramine deposition was employed to visualize regional blood flow distributions in rabbit left ventricular myocardium. A fluctuated pattern of myocardial flow and its dependence on arterial oxygen tension (PaO2) was evaluated with the coefficient of variation (CV) computed at each step of coarse-graining; flow images were revisualized by increasing pixel area (PA) step by step from 0.01 to 1 mm2. The CV values decreased with hypoxia at all resolution levels, suggesting that there is a vascular regulatory mechanism for making myocardial perfusion uniform in response to decreased PaO2. In both perfusion states, Cl/decreased with increasing PA. The relationship between CV and PA fitted the noninteger power law function, implying an apparent fractality of CV.

 
  • REFERENCES

  • 1 Yipintsoi T, Dobbs Jr WA, Scanlon PD, Knopp TJ, Bassingthwaighte JB. Regional distribution of diffusible tracers and carbonized microspheres in the left ventricle of isolated dog heart. Circ Res 1973; 33: 573-87.
  • 2 King RB, Bassingthwaighte JB, Hales JRS, Rowell LB. Stability of heterogeneity of myocardial blood flow in normal awake baboons. Circ Res 1985; 57: 285-95.
  • 3 King RB, Bassingthwaighte JB. Temporal fluctuations in regional myocardial flows. Pfluegers Arch 1989; 413: 336-42.
  • 4 Matsumoto T, Goto M, Tachibana H, Ogasawara Y, Tsujioka K, Kajiya F. Microheterogeneity of myocardial blood flow in rabbit hearts during normoxic and hypoxic states. Am J Physiol 1996; 270: H435-41.
  • 5 Little SE, Bassingthwaighte JB. Plasmasoluble marker for intraorgan regional flows. Am J Physiol 1983; 245: H707-12.
  • 6 Little SE, Link JM, Krohn KA, Bassingthwaighte JB. Myocardial extraction and retention of 2-iododesmethylimipramine: a novel flow marker. Am J Physiol 1986; 250: H1060-70.
  • 7 Kassab GS, Rider CA, Tang NJ, Fung YCB. Morphometry of pig coronary arterial trees. Am J Physiol 1993; 265: H350-65.
  • 8 Bassingthwaighte JB, King RB, Roger’ SA. Fractal nature of regional myocardial blood flow heterogeneity. Circ Res 1989; 65: 578-90.
  • 9 Austin Jr RE, Smedira NG, Squiers TM, Hoffman JIE. Influence of cardiac contraction and coronary vasomotor tone on regional myocardial blood flow. Am J Physiol 1994; 266: H2542-53.
  • 10 Weiss HR, Neubauer JA, Lipp JA, Sinha AK. Quantitative determination of regional oxygen consumption in the dog heart. Circ Res 1978; 42: 394-401.
  • 11 Bassingthwaighte JB, Beyer RP. Fractal correlation in heterogeneous systems. Physica D 1991; 53: 71-84.
  • 12 Hamburger D, Biham O, Avnir D. Apparent fractality emerging from models of random distributions. Phys. Rev. E 1996; 53: 3342-58.
  • 13 Secomb TW. Flow-dependent rheological properties of blood in capillary. Microvasc Res 1987; 34: 46-58.
  • 14 Warnke KC, Skalak TC. In vivo measurement of leukocyte viscosity during capillary plugging. J Biomech Eng 1992; 114: 533-8.
  • 15 Ellis CG, Groom AC. Heterogeneity of red blood cell perfusion in capillary networks supplied by a single arteriole in resting skeletal muscle. Circ Res 1994; 75: 357-68.
  • 16 Pries AR, Secomb TW, Gaehtgens P. Relationship between structural and hemodynamic heterogeneity in microvascular networks. Am J Physiol 1996; 270: H545-53.
  • 17 Mori H, Chujo M, Haruyama S. et al. Local continuity of myocardial blood flow studied by monochromatic synchrotron radiationexcited X-ray fluorescence spectrometry. Circ Res 1995; 76: 1088-100.