Summary
The radiochemical purity of the cobalt-57 complex of bleomycin could be enhanced by
adjusting the pH of the final product to a value between 5 and 6. This radiopharmaceutical
appeared to have better tumor visualizing properties compared to the not neutralized
preparation.
The clinical use of the cobalt-57 bleomycin complex is however limited by the long
physical half-life of the label, causing a risk of radioactive contamination. It appeared
to be possible to label bleomycin with radioactive cations (111In3+, 99mTc4+, 197Hg2+ and 67Cu2+) having suitable gamma ray energies and short half-lifes.
These bleomycin complexes showed a high radiochemical purity judged by their behaviour
on thin layer chromatography, paper chromatography, and electrophoresis, but their
application as tumor visualizing radiopharmaceutical turned out to be disappointing
compared with cobalt-57 bleomycin.
Es war möglich, die radiochemische Reinheit des Kobalt-57 Bleomycin-Komplexes durch
die Einstellung des pH auf 5 bis 6 zu verbessern. Dieses Radiopharmakon hat bessere
Eigenschaften zum Nachweis von Tumoren als das saure Präparat.
Der klinische Wert von Kobalt-57 Bleomycin ist leider beschränkt durch die lange physikalische
Halbwertzeit.
Es war möglich, Bleomycin mit radioaktiven Kationen (111In3+, 99mTc4+, 197Hg2+ und 67Cu2+) mit geeigneten Photonenenergien und kurzer Halbwertzeit zu markieren.
Diese Bleomycin-Komplexe zeigten eine große radiochemische Reinheit bei der Bestimmung
mit Dünnschicht - Chromatographie, Papier - Chromatographie und Elektrophorese. Die
Anwendung als Radiopharmazeutikum zum Nachweis von Tumoren in vivo war im Vergleich
mit Kobalt-57 Bleomycin enttäuschend.