J Reconstr Microsurg 2016; 32(08): 594-598
DOI: 10.1055/s-0036-1584217
Original Article
Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Anatomical Origins of Radial Artery Perforators Evaluated Using Color Doppler Ultrasonography

Ema Onode
1   Department of Orthopaedic Surgery, Osaka City University, Osaka, Japan
,
Kiyohito Takamatsu
2   Department of Orthopaedic Surgery, Yodogawa Christian Hospital, Osaka, Japan
,
Kosuke Shintani
1   Department of Orthopaedic Surgery, Osaka City University, Osaka, Japan
,
Takuya Yokoi
1   Department of Orthopaedic Surgery, Osaka City University, Osaka, Japan
,
Takuya Uemura
1   Department of Orthopaedic Surgery, Osaka City University, Osaka, Japan
,
Mitsuhiro Okada
1   Department of Orthopaedic Surgery, Osaka City University, Osaka, Japan
,
Kenichi Kazuki
3   Department of Orthopaedic Surgery, Gakuen-Minami Clinic, Nara, Japan
,
Hiroaki Nakamura
1   Department of Orthopaedic Surgery, Osaka City University, Osaka, Japan
› Author Affiliations
Further Information

Publication History

13 December 2015

19 April 2016

Publication Date:
08 June 2016 (online)

Abstract

Background The radial artery perforator (RAP) flap has been widely used for covering hand and forearm defects, and real-time accurate perforator mapping is important in planning and elevating the perforator flap. The origins of perforators, especially the superficial and ulnar perforators, arising from the radial artery are very important in the elevation of the RAP flap. Recently, color Doppler ultrasonography (US) using a higher frequency transducer has been developed for high-quality detection of lower flow in smaller vessels. This study aimed to identify the anatomical locations and origins of perforators arising from the radial artery using color Doppler US in healthy volunteers.

Methods Twenty forearms of 10 volunteers were examined.

Results In total, 120 perforators arising from the radial artery were identified 15 cm proximal to the distal wrist crease, with an average of six perforators per forearm. More than half the perforators (n = 72, 60%) were located within 50 mm proximal to the distal wrist crease. Regarding the perforator origins in the axial view, 40 perforators (33%) were located in the radial aspect of the radial artery, 47 (39%) in the ulnar aspect, 15 (13%) in the superficial aspect, and 18 (15%) in the deep aspect. In total, 62 (52%) perforators were located in the superficial and ulnar areas, which are important in nourishing and elevating the RAP flap.

Conclusion We are the first to evaluate RAP using color Doppler US. This noninvasive, convenient, and real-time technique could be useful for preoperative planning and reliably elevating the RAP flaps.

 
  • References

  • 1 Blondeel PN, Beyens G, Verhaeghe R , et al. Doppler flowmetry in the planning of perforator flaps. Br J Plast Surg 1998; 51 (3) 202-209
  • 2 Su W, Lu L, Lazzeri D , et al. Contrast-enhanced ultrasound combined with three-dimensional reconstruction in preoperative perforator flap planning. Plast Reconstr Surg 2013; 131 (1) 80-93
  • 3 Smit JM, Klein S, Werker PM. An overview of methods for vascular mapping in the planning of free flaps. J Plast Reconstr Aesthet Surg 2010; 63 (9) e674-e682
  • 4 Hallock GG. Doppler sonography and color duplex imaging for planning a perforator flap. Clin Plast Surg 2003; 30 (3) 347-357 , v–vi
  • 5 Khan UD, Miller JG. Reliability of handheld Doppler in planning local perforator-based flaps for extremities. Aesthetic Plast Surg 2007; 31 (5) 521-525
  • 6 Goffin D, Brunelli F, Galbiatti A, Sammut D, Gilbert A. A new flap based on the distal branches of the radial artery. Ann Chir Main Memb Super 1992; 11 (3) 217-225
  • 7 Weinzweig N, Chen L, Chen ZW. The distally based radial forearm fasciosubcutaneous flap with preservation of the radial artery: an anatomic and clinical approach. Plast Reconstr Surg 1994; 94 (5) 675-684
  • 8 Koshima I, Moriguchi T, Etoh H, Tsuda K, Tanaka H. The radial artery perforator-based adipofascial flap for dorsal hand coverage. Ann Plast Surg 1995; 35 (5) 474-479
  • 9 Rambe B, Pho RW. Distal radial fasciocutaneous flap. Ann Acad Med Singapore 1995; 24 (4, Suppl): 77-81
  • 10 Jeng SF, Wei FC. The distally based forearm island flap in hand reconstruction. Plast Reconstr Surg 1998; 102 (2) 400-406
  • 11 Ho AM, Chang J. Radial artery perforator flap. J Hand Surg Am 2010; 35 (2) 308-311
  • 12 Uemura T, Takamatsu K, Okada M, Ikeda M, Nakamura H. Radial artery perforator adiposal flap for coverage of the scarred median nerve. J Plast Reconstr Aesthet Surg 2013; 66 (7) 1019-1021
  • 13 Saint-Cyr M, Mujadzic M, Wong C, Hatef D, Lajoie AS, Rohrich RJ. The radial artery pedicle perforator flap: vascular analysis and clinical implications. Plast Reconstr Surg 2010; 125 (5) 1469-1478
  • 14 Cina A, Salgarello M, Barone-Adesi L, Rinaldi P, Bonomo L. Planning breast reconstruction with deep inferior epigastric artery perforating vessels: multidetector CT angiography versus color Doppler US. Radiology 2010; 255 (3) 979-987
  • 15 Scott JR, Liu D, Said H, Neligan PC, Mathes DW. Computed tomographic angiography in planning abdomen-based microsurgical breast reconstruction: a comparison with color duplex ultrasound. Plast Reconstr Surg 2010; 125 (2) 446-453
  • 16 Bhattacharya V, Agrawal NK, Chaudhary GR, Arvind S, Bhattacharya S. CT angiographic evaluation of perforators in the lower limb and their reconstructive implication. Indian J Plast Surg 2012; 45 (3) 494-497
  • 17 Rand RP, Cramer MM, Strandness Jr DE. Color-flow duplex scanning in the preoperative assessment of TRAM flap perforators: a report of 32 consecutive patients. Plast Reconstr Surg 1994; 93 (3) 453-459
  • 18 Ayhan S, Oktar SO, Tuncer S, Yucel C, Kandal S, Demirtas Y. Correlation between vessel diameters of superficial and deep inferior epigastric systems: Doppler ultrasound assessment. J Plast Reconstr Aesthet Surg 2009; 62 (9) 1140-1147
  • 19 Panagiotopoulos K, Soucacos PN, Korres DS , et al. Anatomical study and colour Doppler assessment of the skin perforators of the anterior tibial artery and possible clinical applications. J Plast Reconstr Aesthet Surg 2009; 62 (11) 1524-1529
  • 20 Patel RS, Higgins KM, Enepekides DJ, Hamilton PA. Clinical utility of colour flow Doppler ultrasonography in planning anterolateral thigh flap harvest. J Otolaryngol Head Neck Surg 2010; 39 (5) 566-571
  • 21 Ensat F, Babl M, Conz C , et al. The efficacy of color duplex sonography in preoperative assessment of anterolateral thigh flap. Microsurgery 2012; 32 (8) 605-610
  • 22 Ulatowski Ł. Colour Doppler assessment of the perforators of anterolateral thigh flap and its usefulness in preoperative planning. Pol Przegl Chir 2012; 84 (3) 119-125
  • 23 Salgarello M, Visconti G, Barone-Adesi L, Cina A. The retrograde limb of internal mammary vessels as reliable recipient vessels in DIEP flap breast reconstruction: a clinical and radiological study. Ann Plast Surg 2015; 74 (4) 447-453
  • 24 Shen XQ, Shen H, Xu JH, Wu SC, Chen Q, Chen B. Color Doppler imaging of an ulnar artery perforator forearm flap for resurfacing finger defects. Ann Plast Surg 2014; 73 (1) 43-45