J Reconstr Microsurg 2015; 31(05): 327-335
DOI: 10.1055/s-0034-1395415
Original Article
Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Single-Lumen and Multi-Lumen Poly(Ethylene Glycol) Nerve Conduits Fabricated by Stereolithography for Peripheral Nerve Regeneration In Vivo

Maristella S. Evangelista
1   Department of Plastic Surgery, University of California, Irvine, Orange, California
,
Mireya Perez
2   W.M. Keck Center for 3D Innovation, University of Texas at El Paso, El Paso, Texas
,
Ara A. Salibian
1   Department of Plastic Surgery, University of California, Irvine, Orange, California
,
Jeffrey M. Hassan
1   Department of Plastic Surgery, University of California, Irvine, Orange, California
,
Sean Darcy
1   Department of Plastic Surgery, University of California, Irvine, Orange, California
,
Keyianoosh Z. Paydar
1   Department of Plastic Surgery, University of California, Irvine, Orange, California
,
Ryan B. Wicker
2   W.M. Keck Center for 3D Innovation, University of Texas at El Paso, El Paso, Texas
,
Karina Arcaute
2   W.M. Keck Center for 3D Innovation, University of Texas at El Paso, El Paso, Texas
,
Brenda K. Mann
3   Department of Bioengineering, University of Utah, Salt Lake City, Utah
,
Gregory R. D. Evans
1   Department of Plastic Surgery, University of California, Irvine, Orange, California
› Author Affiliations
Further Information

Publication History

21 June 2014

06 September 2014

Publication Date:
20 April 2015 (online)

Abstract

Background The use of nerve conduits to facilitate nerve regrowth after peripheral nerve injury is limited to defects less than 3 cm. The purpose of this study is to determine the capability of novel single and multi-lumen poly(ethylene glycol) (PEG) conduits manufactured by stereolithography to promote peripheral nerve regeneration.

Materials and Methods Eight Sprague Dawley rats with sharp transection injuries of the sciatic nerve were randomly assigned to receive single-lumen or multi-lumen PEG conduits to bridge a 10-mm gap. Sciatic nerve and conduit samples were harvested after 5 weeks, and axon number, myelin thickness, fiber diameter, and g-ratio were analyzed. The contralateral intact nerve was also harvested for comparison.

Results Partial nerve regeneration was observed in three out of four single-lumen conduits and one out of four multi-lumen conduits. Axon number in the single-lumen regenerated nerve approached that of the contralateral intact nerve at 4,492 ± 2,810.0 and 6,080 ± 627.9 fibers/mm2, respectively. The percentage of small fibers was greater in the single-lumen conduit compared with the intact nerve, whereas myelin thickness and g-ratio were consistently greater in the autologous nerve. Axon regrowth through the multi-lumen conduits was severely limited.

Conclusion Single-lumen stereolithography-manufactured PEG nerve conduits promote nerve regeneration, with regenerating axon numbers approaching that of normal nerve. Multi-lumen conduits demonstrated significantly less nerve regeneration, possibly due to physical properties of the conduit inhibiting growth. Further studies are necessary to compare the efficacy of the two conduits for functional recovery and to elucidate the reasons underlying their differences in nerve regeneration potential.

 
  • References

  • 1 Noble J, Munro CA, Prasad VS, Midha R. Analysis of upper and lower extremity peripheral nerve injuries in a population of patients with multiple injuries. J Trauma 1998; 45 (1) 116-122
  • 2 Jiang X, Lim SH, Mao HQ, Chew SY. Current applications and future perspectives of artificial nerve conduits. Exp Neurol 2010; 223 (1) 86-101
  • 3 Mackinnon SE, Hudson AR. Clinical application of peripheral nerve transplantation. Plast Reconstr Surg 1992; 90 (4) 695-699
  • 4 Schmidt CE, Leach JB. Neural tissue engineering: strategies for repair and regeneration. Annu Rev Biomed Eng 2003; 5: 293-347
  • 5 Wiberg M, Terenghi G. Will it be possible to produce peripheral nerves?. Surg Technol Int 2003; 11: 303-310
  • 6 Kehoe S, Zhang XF, Boyd D. FDA approved guidance conduits and wraps for peripheral nerve injury: a review of materials and efficacy. Injury 2012; 43 (5) 553-572
  • 7 Pabari A, Yang SY, Seifalian AM, Mosahebi A. Modern surgical management of peripheral nerve gap. J Plast Reconstr Aesthet Surg 2010; 63 (12) 1941-1948
  • 8 Deal DN, Griffin JW, Hogan MV. Nerve conduits for nerve repair or reconstruction. J Am Acad Orthop Surg 2012; 20 (2) 63-68
  • 9 Pang TH. Advances in stereolithography photopolymer systems. In: Jacobs PF, , ed. Stereolithography and Other RP&M Technologies from Rapid Prototyping to Rapid Tooling. Dearborn, Michigan: Society of Manufacturing Engineers in Cooperation with Rapid Prototyping Association of SME; 1996: 27-80
  • 10 Arcaute K, Mann BK, Wicker RB. Stereolithography of three-dimensional bioactive poly(ethylene glycol) constructs with encapsulated cells. Ann Biomed Eng 2006; 34 (9) 1429-1441
  • 11 Cooke M, Fisher JP, Dean D, Rimnac C, Mikos AG. Use of stereolithography to manufacture critical-sized 3D biodegradable scaffolds for bone ingrowth. J Biomed Mater Res B Appl Biomater 2002; 64B (2) 65-69
  • 12 Lee KW, Wang S, Fox BC, Ritman EL, Yaszemski MJ, Lu L. Poly(propylene fumarate) bone tissue engineering scaffold fabrication using stereolithography: effects of resin formulations and laser parameters. Biomacromolecules 2007; 8 (4) 1077-1084
  • 13 Barry JJ, Evseev AV, Markov MA , et al. In vitro study of hydroxyapatite-based photocurable polymer composites prepared by laser stereolithography and supercritical fluid extraction. Acta Biomater 2008; 4 (6) 1603-1610
  • 14 Arcaute K, Mann BK, Wicker RB. Fabrication of off-the-shelf multilumen poly(ethylene glycol) nerve guidance conduits using stereolithography. Tissue Eng Part C Methods 2011; 17 (1) 27-38
  • 15 Gunn JW, Turner SD, Mann BK. Adhesive and mechanical properties of hydrogels influence neurite extension. J Biomed Mater Res A 2005; 72 (1) 91-97
  • 16 Mann BK, Gobin AS, Tsai AT, Schmedlen RH, West JL. Smooth muscle cell growth in photopolymerized hydrogels with cell adhesive and proteolytically degradable domains: synthetic ECM analogs for tissue engineering. Biomaterials 2001; 22 (22) 3045-3051
  • 17 Zalispky S, Harris J. Poly(Ethylene Glycol) Chemistry and Biological Applications. Washington, DC: American Chemical Society Series; 1997: 680
  • 18 Arcaute K, Mann B, Wicker R. Stereolithography of spatially controlled multi-material bioactive poly(ethylene glycol) scaffolds. Acta Biomater 2010; 6 (3) 1047-1054
  • 19 Archibald SJ, Krarup C, Shefner J, Li ST, Madison RD. A collagen-based nerve guide conduit for peripheral nerve repair: an electrophysiological study of nerve regeneration in rodents and nonhuman primates. J Comp Neurol 1991; 306 (4) 685-696
  • 20 Dellon AL, Mackinnon SE. An alternative to the classical nerve graft for the management of the short nerve gap. Plast Reconstr Surg 1988; 82 (5) 849-856
  • 21 Den Dunnen WF, Van der Lei B, Schakenraad JM , et al. Long-term evaluation of nerve regeneration in a biodegradable nerve guide. Microsurgery 1993; 14 (8) 508-515
  • 22 Molander H, Olsson Y, Engkvist O, Bowald S, Eriksson I. Regeneration of peripheral nerve through a polyglactin tube. Muscle Nerve 1982; 5 (1) 54-57
  • 23 Seckel BR, Chiu TH, Nyilas E, Sidman RL. Nerve regeneration through synthetic biodegradable nerve guides: regulation by the target organ. Plast Reconstr Surg 1984; 74 (2) 173-181
  • 24 Konofaos P, Ver Halen JP. Nerve repair by means of tubulization: past, present, future. J Reconstr Microsurg 2013; 29 (3) 149-164
  • 25 de Ruiter GC, Onyeneho IA, Liang ET , et al. Methods for in vitro characterization of multichannel nerve tubes. J Biomed Mater Res A 2008; 84 (3) 643-651
  • 26 Flynn L, Dalton PD, Shoichet MS. Fiber templating of poly(2-hydroxyethyl methacrylate) for neural tissue engineering. Biomaterials 2003; 24 (23) 4265-4272
  • 27 Hadlock T, Elisseeff J, Langer R, Vacanti J, Cheney M. A tissue-engineered conduit for peripheral nerve repair. Arch Otolaryngol Head Neck Surg 1998; 124 (10) 1081-1086
  • 28 Hadlock T, Sundback C, Hunter D, Cheney M, Vacanti JP. A polymer foam conduit seeded with Schwann cells promotes guided peripheral nerve regeneration. Tissue Eng 2000; 6 (2) 119-127
  • 29 Moore MJ, Friedman JA, Lewellyn EB , et al. Multiple-channel scaffolds to promote spinal cord axon regeneration. Biomaterials 2006; 27 (3) 419-429
  • 30 Sundback C, Hadlock T, Cheney M, Vacanti J. Manufacture of porous polymer nerve conduits by a novel low-pressure injection molding process. Biomaterials 2003; 24 (5) 819-830
  • 31 Yang Y, De Laporte L, Rives CB , et al. Neurotrophin releasing single and multiple lumen nerve conduits. J Control Release 2005; 104 (3) 433-446
  • 32 Sanders FK, Whitteridge D. Conduction velocity and myelin thickness in regenerating nerve fibres. J Physiol 1946; 105 (2) 152-174
  • 33 Scholz T, Rogers JM, Krichevsky A, Dhar S, Evans GR. Inducible nerve growth factor delivery for peripheral nerve regeneration in vivo. Plast Reconstr Surg 2010; 126 (6) 1874-1889
  • 34 de Ruiter GC, Spinner RJ, Malessy MJ , et al. Accuracy of motor axon regeneration across autograft, single-lumen, and multichannel poly(lactic-co-glycolic acid) nerve tubes. Neurosurgery 2008; 63 (1) 144-153 , discussion 153–155
  • 35 Lynn AD, Kyriakides TR, Bryant SJ. Characterization of the in vitro macrophage response and in vivo host response to poly(ethylene glycol)-based hydrogels. J Biomed Mater Res A 2010; 93 (3) 941-953