Horm Metab Res 2013; 45(10): 765-768
DOI: 10.1055/s-0033-1349891
Immediate Interest
© Georg Thieme Verlag KG Stuttgart · New York

A Pilot Study Evaluating 99mTc-anti-TNF-alpha Scintigraphy in Graves’ Ophtalmopathy Patients with Different Clinical Activity Score

Authors

  • E. dos S. Rebelo Pinto

    1   Departamento de Radiologia e Departamento de Clínica Médica, Faculdade de Medicina, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
  • F. P. P. L. Lopes

    1   Departamento de Radiologia e Departamento de Clínica Médica, Faculdade de Medicina, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
  • S. A. L. de Souza

    1   Departamento de Radiologia e Departamento de Clínica Médica, Faculdade de Medicina, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
  • L. M. B. da Fonseca

    1   Departamento de Radiologia e Departamento de Clínica Médica, Faculdade de Medicina, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
  • M. Vaisman

    1   Departamento de Radiologia e Departamento de Clínica Médica, Faculdade de Medicina, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
  • B. Gutfilen

    1   Departamento de Radiologia e Departamento de Clínica Médica, Faculdade de Medicina, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
  • P. de F. dos Santos Teixeira

    1   Departamento de Radiologia e Departamento de Clínica Médica, Faculdade de Medicina, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
Further Information

Publication History

received 27 December 2012

accepted after second revision 25 June 2013

Publication Date:
05 August 2013 (online)

Preview

Abstract

The present study describes the preliminary results of the use of 99mTc-anti-TNF-α scintigraphy as a new diagnostic approach to evaluate patients presenting with Graves’ ophthalmopathy (GO). Patients (n=25) presenting at different inflammatory stages of GO and 10 healthy volunteers underwent 99mTc-anti-TNF-α scintigraphy. Images were obtained 15 min after the intravenous injection of 370 MBq (10 mCi) 99mTc-anti-TNF-α. Planar images were obtained in a 256×256 matrix (each lasting 5 min) and single photon emission computed tomography (SPECT) scan lasting 13 min. Regions of interest (ROI) were drawn on the orbit and cerebral hemispheres. The uptake of 99m Tc-anti-TNF-α in these regions was compared and positive scintigraphy established when the ROI was >2.5. In addition, uptake for each positive exam was scored as either slight (2.6–5.1), moderate (5.2–7.6), or high (>7.6). In this pilot study, 69 orbits were evaluated (1 patient had only 1 eye), and 27 had a positive CAS (≥3/7). Scintigraphies were positive in 38 orbits. Comparing the results of the exams with CAS, a high sensitivity and negative predictive values were determined for scintigraphy (96.3% and 96.7%, respectively). However, the specificity and the positive predictive values were 71.4% and 68.4%, respectively, with an accuracy of 81.2%. The exclusion of examinations that were slightly positive from the analysis resulted in an improvement in test accuracy (95.5%). The preliminary results suggest that 99mTc-anti-TNF-α scintigraphy is a promising procedure for the evaluation of active orbital inflammation in GO.