Endoscopy 2022; 54(03): 281-289
DOI: 10.1055/a-1459-4571
Original article

Water exchange-assisted versus carbon dioxide-insufflated single-balloon enteroscopy: a randomized controlled trial

Shaopeng Liu*
1   State Key Laboratory of Cancer Biology and National Clinical Research Center for Digestive Diseases, Xijing Hospital of Digestive Diseases, Fourth Military Medical University, Xi’an, China
,
Tao Dong*
1   State Key Laboratory of Cancer Biology and National Clinical Research Center for Digestive Diseases, Xijing Hospital of Digestive Diseases, Fourth Military Medical University, Xi’an, China
,
Yupeng Shi
1   State Key Laboratory of Cancer Biology and National Clinical Research Center for Digestive Diseases, Xijing Hospital of Digestive Diseases, Fourth Military Medical University, Xi’an, China
,
Hui Luo
1   State Key Laboratory of Cancer Biology and National Clinical Research Center for Digestive Diseases, Xijing Hospital of Digestive Diseases, Fourth Military Medical University, Xi’an, China
,
Xianmin Xue
1   State Key Laboratory of Cancer Biology and National Clinical Research Center for Digestive Diseases, Xijing Hospital of Digestive Diseases, Fourth Military Medical University, Xi’an, China
,
Yijin Zhu
1   State Key Laboratory of Cancer Biology and National Clinical Research Center for Digestive Diseases, Xijing Hospital of Digestive Diseases, Fourth Military Medical University, Xi’an, China
,
Xiangping Wang
1   State Key Laboratory of Cancer Biology and National Clinical Research Center for Digestive Diseases, Xijing Hospital of Digestive Diseases, Fourth Military Medical University, Xi’an, China
,
Biaoluo Wang
1   State Key Laboratory of Cancer Biology and National Clinical Research Center for Digestive Diseases, Xijing Hospital of Digestive Diseases, Fourth Military Medical University, Xi’an, China
,
Shuhui Liang
1   State Key Laboratory of Cancer Biology and National Clinical Research Center for Digestive Diseases, Xijing Hospital of Digestive Diseases, Fourth Military Medical University, Xi’an, China
,
Yanglin Pan
1   State Key Laboratory of Cancer Biology and National Clinical Research Center for Digestive Diseases, Xijing Hospital of Digestive Diseases, Fourth Military Medical University, Xi’an, China
,
Xuegang Guo
1   State Key Laboratory of Cancer Biology and National Clinical Research Center for Digestive Diseases, Xijing Hospital of Digestive Diseases, Fourth Military Medical University, Xi’an, China
,
Kaichun Wu
1   State Key Laboratory of Cancer Biology and National Clinical Research Center for Digestive Diseases, Xijing Hospital of Digestive Diseases, Fourth Military Medical University, Xi’an, China
› Author Affiliations

Supported by: National Natural Science Foundation of China 81472778 Supported by: National Natural Science Foundation of China 81571731 Supported by: National Natural Science Foundation of China 81627807 Supported by: Clinical New Techniques Project of Xijing Hospital XJGX13LZ02 Supported by: Science Foundation of Shanxi Province 2018SF-161 Trial Registration: ClinicalTrials.gov (https://clinicaltrials.gov/) Registration number (trial ID): NCT01942863 Type of study: Prospective, Randomized, Controlled, Patient-blinded Trial


Preview

Abstract

Background Single-balloon enteroscopy (SBE) is a valuable but difficult modality for the diagnosis and treatment of small-bowel disease. The water exchange method has the advantage of facilitating intubation during colonoscopy. Here, we evaluated the effects of water exchange on procedure-related variables related to SBE.

Methods This randomized controlled trial was conducted in a tertiary-care referral center in China. Patients due for attempted total enteroscopy were randomly allocated to undergo water exchange-assisted (water exchange group) or carbon dioxide-insufflated enteroscopy (CO2 group). All patients were planned to undergo both anterograde and retrograde procedures. The primary outcome was the total enteroscopy rate. Secondary outcomes included the maximal insertion depth, positive findings, procedural time, and adverse events.

Results: In total, 110 patients were enrolled, with 55 in each group. Baseline characteristics between the two groups were comparable. Total enteroscopy was achieved in 58.2 % (32/55) of the water exchange group and 36.4 % (20/55) of the control group (P = 0.02). The mean (standard deviation) estimated intubation depth was 521.2 (101.4) cm in the water exchange group and 481.6 (95.2) cm in the CO2 group (P = 0.04). The insertion time was prolonged in the water exchange group compared with the CO2 group (178.9 [45.1] minutes vs. 154.2 [27.6] minutes; P < 0.001). Endoscopic findings and adverse events were comparable between the two groups.

Conclusions: The water exchange method improved the total enteroscopy rate and increased the intubation depth during SBE. The use of water exchange did not increase the complications of enteroscopy.

* Contributed equally to this work


Supplementary material



Publication History

Received: 10 October 2020

Accepted after revision: 22 March 2021

Accepted Manuscript online:
22 March 2021

Article published online:
17 September 2021

© 2021. Thieme. All rights reserved.

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany