Utilizing Indocyanine Green Dye Angiography to Detect Simulated Flap Venous Congestion in a Novel Experimental Rat Model

Ahmed Nasser
1   Department of Surgery, Stony Brook University Medical Center, Stony Brook, New York
,
Mitchell S. Fourman
2   Department of Orthopaedic Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
,
Robert P. Gersch
3   Department of Surgery, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
,
Brett T. Phillips
4   Division of Plastic Surgery, Department of Surgery, Duke University Medical Center, Durham, North Carolina
,
Hsingli Kai Hsi
5   School of Medicine, Stony Brook University Medical Center, Stony Brook, New York
,
Sami U. Khan
6   Division of Plastic Surgery, Department of Surgery, Stony Brook University Medical Center, Stony Brook, New York
,
Mark A. Gelfand
6   Division of Plastic Surgery, Department of Surgery, Stony Brook University Medical Center, Stony Brook, New York
,
Alexander B. Dagum
6   Division of Plastic Surgery, Department of Surgery, Stony Brook University Medical Center, Stony Brook, New York
,
Duc T. Bui
6   Division of Plastic Surgery, Department of Surgery, Stony Brook University Medical Center, Stony Brook, New York
› Institutsangaben
Weitere Informationen

Publikationsverlauf

10. Februar 2015

10. Mai 2015

Publikationsdatum:
01. September 2015 (online)

Preview

Abstract

Background Venous congestion is a leading cause for free flap failure and still relies on clinical observation as the diagnostic gold standard. We sought to characterize blood flow in a variable venous congestion murine hind limb model using indocyanine green (ICG, SPY Pack, LifeCell, Branchburg, NJ) angiography.

Methods Male Sprague–Dawley rats (Charles River, Hudson, NY) underwent bilateral partial amputation at the inguinal ligament, leaving only the femoral vessels and femur intact. Complete unilateral venous occlusion was achieved via suture ligation, while partial occlusion was achieved by surrounding the femoral vein with a synthetic microtube to achieve 25, 75, 85, or 92% occlusion. Relative blood flow of occluded and control limbs was tracked with ICG angiography throughout a 90-minute time course.

Results ICG angiography detected statistically significant (p < 0.05) reductions in limb blood flow 1 and 2 minutes following ICG injection in the 100, 92, and 85% occluded limbs when compared with contralateral control limbs. Dynamic tracking using the slope of ICG inflow for 45 seconds postinjection reflected this same significant difference. No statistically significant change in limb blood flow or dye influx rate was observed in the 25 and 75% occlusion groups.

Conclusions ICG angiography can detect venous congestion in a rat lower extremity model reliably at occlusion rates ≥ 85%. This method may offer surgeons an intraoperative diagnostic tool to identify venous congestion at extremely early time points, allowing for immediate intervention. Further investigation and characterization is warranted in a larger animal model before clinical adaptation.

Note

This article was presented as LOP22: Utilizing indocyanine green angiography in the evaluation of varying levels of venous congestion in a novel rat model. Paper presented at: 6th European Plastic Surgery Research Council; August 21–24, 2014; Hamburg, Germany; 133: Indocyanine green angiography predicts flap pedicle venous congestion within one minute of occlusion in rat models. 58th Annual Meeting of Plastic Surgery Research Council; May 2–4, 2013; Santa Monica, CA; and Can laser assisted indocyanine green dye angiography detect venous congestion more reliably than clinical assessment in a rat venous occlusion model. 30th Annual Meeting of Northeastern Society of Plastic Surgeons; September 20–22, 2013; Washington, DC.