J Am Acad Audiol 2009; 20(03): 180-186
DOI: 10.3766/jaaa.20.3.4
Articles
American Academy of Audiology. All rights reserved. (2009) American Academy of Audiology

Bilateral Idiopathic Sensorineural Hearing Loss following Dental Surgery

Richard H. Wilson
,
Charles E. Witkowski
,
Ashley A.S. Wilson
Further Information

Publication History

Publication Date:
06 August 2020 (online)

Background: This is a case study of an 18-year-old female who suffered a bilateral idiopathic sensorineural hearing loss that was coincident with the removal of four impacted wisdom teeth. Throughout childhood the patient had normal hearing for pure tones bilaterally as measured at the pediatrician's office. One month prior to dental surgery (May) the patient volunteered to participate in an auditory experiment at which time her pure-tone audiogram was normal. Immediately following surgery (June), the patient had substantial swelling of the face and complained of some hearing loss with no other auditory/vestibular complaints. The following month (July) during the course of a routine physical examination a pure-tone audiogram revealed bilateral, air-conduction thresholds of 30–35 dB HL (500–4000 Hz) and 20 dB HL (8000 Hz). Because bone conduction was not tested, it is impossible to know whether the hearing loss was conductive, mixed, or sensorineural. The pediatrician thought that the hearing loss was conductive and would resolve as the edema subsided. A month later (August) the subject again volunteered for an auditory experiment at which time her hearing again was tested.

Purpose: The purpose of this report is to detail the dental procedures involved in the extraction of the wisdom teeth, to report the results of a variety and series of post-op hearing tests, and to discuss the possible mechanisms that might be involved in the “idiopathic” bilateral sensorineural hearing loss.

Research Design: Case report.

Results: During the August visit to the laboratory, hearing for pure tones bilaterally was 0 to 5 dB HL at 250–1000 Hz with a 40–45 dB HL notch at 2000 Hz with a return to 10 dB HL at 8000 Hz. Air conduction and bone conduction thresholds were equivalent. Word recognition in quiet was ≥92 percent correct for both ears, whereas the signal-to-noise ratio (SNR) hearing loss measured with the Words-in-Noise test was high normal in the left ear with a mild SNR hearing loss in the right ear. Tympanometry and acoustic reflex thresholds were normal. Distortion product otoacoustic emissions were reduced in the 1000–3000 Hz region for both ears, which is consistent with cochlear hearing loss. The hearing loss has remained unchanged for the past 19 months.

Conclusions: The possible etiologies, including insults to the cochleae by vibration trauma and through alterations in the blood supply to the cochleae, are considered.