Vet Comp Orthop Traumatol 2007; 20(04): 305-307
DOI: 10.1160/VCOT-06-11-0091
Brief Communication
Schattauer GmbH

Measurement of velocity with a kinematic system versus a photocell system in the collection of canine ground reaction forces

J. P. Punke
1   Department of Small Animal Medicine and Surgery, College of Veterinary Medicine, Athens, Georgia, USA
,
C. M. Andrews
1   Department of Small Animal Medicine and Surgery, College of Veterinary Medicine, Athens, Georgia, USA
,
A. L. Speas
1   Department of Small Animal Medicine and Surgery, College of Veterinary Medicine, Athens, Georgia, USA
,
L. R. Reynolds
1   Department of Small Animal Medicine and Surgery, College of Veterinary Medicine, Athens, Georgia, USA
,
S. C. Budsberg
1   Department of Small Animal Medicine and Surgery, College of Veterinary Medicine, Athens, Georgia, USA
› Author Affiliations
Further Information

Publication History

Received 29 November 2006

Accepted 19 January 2007

Publication Date:
18 December 2017 (online)

Summary

Velocities obtained from a five photocell system were compared to velocities of nine anatomical points on a handler and canine subject as reported by a kinematic system over the same distance. There was not a statistically significant difference between the velocities of the markers on the dogs’ occipital protuberance and interscapular region compared with the velocity as reported by the photocell system. The average velocities of the three markers on the forelimb of the dogs and three markers on the handler's leg and one on the sacrum had statistically different values than the photocell system. Given these results, photocell systems with the same configuration in this study can be trusted to report accurate trunk velocities of canine subjects during the collection of ground reaction forces.

 
  • References

  • 1 Evans R, Horstman C, Conzemius M. Accuracy and optimization of force platform gait analysis in Labradors with cranial cruciate disease evaluated at a walking gait. Vet Surg 2005; 34: 445-449.
  • 2 Riggs CM, DeCamp CE, Soutas-Little RW. et al. Effects of subject velocity on force plate- measured ground reaction forces in healthy Greyhounds at the trot. Am J Vet Res 1993; 54: 1523-1526.
  • 3 Budsberg SC, Rytz U, Johnston SA. Effects of acceleration on ground reaction forces collected in healthy dogs at a trot. Vet Comp Orthop Traumatol 1999; 12: 15-19.
  • 4 DeCamp CE, Soutas-Little RW, Hauptman J. et al. Kinematic gait analysis of the trot in healthy Greyhounds. Am JVet Res 1993; 54: 627-634.
  • 5 Budsberg SC. Long term temporal evaluation of ground reaction forces in a canine model of osteoarthritis. Am JVet Res 2001; 62: 1207-1211.