Thromb Haemost 2014; 111(05): 862-872
DOI: 10.1160/TH13-09-0752
Platelets and Blood Cells
Schattauer GmbH

Micropatterned array to assess the interaction of single platelets with platelet factor 4-heparin-IgG complexes

Nikolay Medvedev#
1   ZIK HIKE-Zentrum für Innovationskompetenz ˵Humorale Immunreaktionen bei kardiovaskulären Erkrankungen”, Greifswald, Germany
,
Raghavendra Palankar#
1   ZIK HIKE-Zentrum für Innovationskompetenz ˵Humorale Immunreaktionen bei kardiovaskulären Erkrankungen”, Greifswald, Germany
,
Krystin Krauel
2   Institut für Immunologie und Transfusionsmedizin, Greifswald, Germany
,
Andreas Greinacher*
2   Institut für Immunologie und Transfusionsmedizin, Greifswald, Germany
,
Mihaela Delcea*
1   ZIK HIKE-Zentrum für Innovationskompetenz ˵Humorale Immunreaktionen bei kardiovaskulären Erkrankungen”, Greifswald, Germany
› Author Affiliations
Financial support: This study was supported by the German Ministry of Education and Research-BMBF FKZ 03Z2CN11.
Further Information

Publication History

Received: 12 September 2013

Accepted after minor revision: 13 January 2013

Publication Date:
01 December 2017 (online)

Summary

We report a strategy to generate by electron beam lithography high fidelity micropatterned arrays to assess the interaction of single platelets with immobilised ligands. As a proof-of-principle we functionalised the microarrays with platelet factor 4 (PF4)-heparin-IgG complexes. We embedded biotinylated water-soluble quantum dots into polyethylene glycol (PEG)-coated micropatterned arrays and functionalised them via streptavidin to bind biotinylated ligands, here biotinylated-PF4/heparin complexes. The integrity of the PF4/heparin-complexes was shown by binding of anti-PF4/heparin antibodies. Ligand density was quantified by immunofluorescence and immunogold antibody labelling. Real-time calcium imaging was employed for read-out of single platelets activated on micropatterned surfaces functionalised with PF4/heparin-IgG complexes. With the smallest micropatterns (0.5x0.5 µm) we show that single platelets become strongly activated by binding to surface-immobilised PF4/heparin-IgG, while on larger micropatterns (10x10 µm), platelet aggregates formed. These findings that HIT antibodies can cause platelet activation on microarrays illustrate how this novel method opens new avenues to study platelet function at single cell level. Generating functionalized microarray surfaces to which highly complex ligands can be bound and quantified has the potential for platelet and other cell function assays integrated into high-throughput microfluidic microdevices.

# Equal first authors.


* Shared senior authorship.


 
  • References

  • 1 Cattaneo M, Cerletti C, Harrison P. et al. Recommendations for the Standardisation of Light Transmission Aggregometry: A Consensus of the Working Party from the Platelet Physiology Subcommittee of SSC/ISTH. J Thromb Haemost. 2013 epub ahead of print.
  • 2 Arepally GM, Ortel TL. Clinical practice. Heparin-induced thrombocytopenia. N Engl J Med 2006; 355: 809-817.
  • 3 Kelton JG, Arnold DM, Bates SM. Nonheparin anticoagulants for heparin-induced thrombocytopenia. N Engl J Med 2013; 368: 737-744.
  • 4 Amiral J, Bridey F, Dreyfus M. et al. Platelet factor 4 complexed to heparin is the target for antibodies generated in heparin-induced thrombocytopenia. Thromb Haemost 1992; 68: 95-96.
  • 5 Greinacher A, Liebenhoff U, Kiefel V. et al. Heparin-associated thrombocytopenia: the effects of various intravenous IgG preparations on antibody mediated platelet activation--a possible new indication for high dose i.v. IgG. Thromb Haemost 1994; 71: 641-645.
  • 6 Chong BH, Fawaz I, Chesterman CN. et al. Heparin-induced thrombocytopenia: mechanism of interaction of the heparin-dependent antibody with platelets. Br J Haematol 1989; 73: 235-240.
  • 7 Li ZQ, Liu W, Park KS. et al. Defining a second epitope for heparin-induced thrombocytopenia/thrombosis antibodies using KKO, a murine HIT-like monoclonal antibody. Blood 2002; 99: 1230-1236.
  • 8 Greinacher A, Gopinadhan M, Gunther JU. et al. Close approximation of two platelet factor 4 tetramers by charge neutralisation forms the antigens recognized by HIT antibodies. Arterioscl Thromb Vasc Biol 2006; 26: 2386-2393.
  • 9 Kelton JG, Sheridan D, Santos A. et al. Heparin-induced thrombocytopenia: laboratory studies. Blood 1988; 72: 925-930.
  • 10 Newman PM, Swanson RL, Chong BH. Heparin-induced thrombocytopenia: IgG binding to PF4-heparin complexes in the fluid phase and cross-reactivity with low molecular weight heparin and heparinoid. Thromb Haemost 1998; 80: 292-297.
  • 11 Palankar R, Medvedev N, Rong A, Delcea M. Fabrication of quantum dot microarrays using electron beam lithography for applications in analyte sensing and cellular dynamics. ACS Nano 2013; 07: 4617-4628.
  • 12 Krauel K, Potschke C, Weber C. et al. Platelet factor 4 binds to bacteria, [corrected] inducing antibodies cross-reacting with the major antigen in heparin-induced thrombocytopenia. Blood 2011; 117: 1370-1378.
  • 13 Juhl D, Eichler P, Lubenow N. et al. Incidence and clinical significance of anti-PF4/heparin antibodies of the IgG, IgM, and IgA class in 755 consecutive patient samples referred for diagnostic testing for heparin-induced thrombocytopenia. Eur J Haematol 2006; 76: 420-426.
  • 14 Warkentin TE, Greinacher A. Laboratory testing for heparin-induced thrombocytopenia. Heparin-induced Thrombocytopenia. LNew York, NY: Informa Healthcare; 2007: 227-238.
  • 15 Hong Y, Krsko P, Libera M. Protein surface patterning using nanoscale PEG hydrogels. Langmuir 2004; 20: 11123-11126.
  • 16 Krsko P, McCann TE, Thach TT. et al. Length-scale mediated adhesion and directed growth of neural cells by surface-patterned poly(ethylene glycol) hydrogels. Biomaterials 2009; 30: 721-729.
  • 17 Andrade JJ, Brasil AG, Barbosa BJAP. et al. Biocompatible Water Soluble UV-Blue Emitting ZnSe Quantum Dots for Biomedical Applications. Colloidal Quantum Dots for Biomedical Applications V. 2010: 7575.
  • 18 Yu WW, Chang E, Drezek R. et al. Water-soluble quantum dots for biomedical applications. Biochem Biophys Res Commun 2006; 348: 781-786.
  • 19 Bruchez Jr M, Moronne M, Gin P. et al. Semiconductor nanocrystals as fluorescent biological labels. Science 1998; 281: 2013-2016.
  • 20 Basabe-Desmonts L, Ramstrom S, Meade G. et al. Single-step separation of platelets from whole blood coupled with digital quantification by interfacial platelet cytometry (iPC). Langmuir 2010; 26: 14700-14706.
  • 21 Corum LE, Eichinger CD, Hsiao T W. et al. Using microcontact printing of fibrinogen to control surface-induced platelet adhesion and activation. Langmuir 2011; 27: 8316-8322.
  • 22 Kita A, Sakurai Y, Myers DR. et al. Microenvironmental geometry guides platelet adhesion and spreading: a quantitative analysis at the single cell level. PLoS One 2011; 06: e26437.
  • 23 Lopez-Alonso A, Jose B, Somers M. et al. Individual Platelet Adhesion Assay: Measuring Platelet Function and Antiplatelet Therapies in Whole Blood via Digital Quantification of Cell Adhesion. Anal Chem 2013; 85: 6497-6504.
  • 24 Zhang F, Li G, Yang P. et al. Fabrication of biomolecule-PEG micropattern on titanium surface and its effects on platelet adhesion. Colloids Surf B Biointerfaces 2013; 102: 457-465.
  • 25 Van de Walle AB, Fontenot J, Spain TG. et al. The role of fibrinogen spacing and patch size on platelet adhesion under flow. Acta Biomater 2012; 08: 4080-4091.
  • 26 Horsewood P, Hayward CP, Warkentin TE. et al. Investigation of the mechanisms of monoclonal antibody-induced platelet activation. Blood 1991; 78: 1019-1026.
  • 27 Warkentin TE. Clinical picture of heparin induced thrombocytopenia. Warkentin TE, Greinacher A. Heparin induced thrombocytopenia. Boca Raton, London: New York CrC Press; 2013: 24-76.
  • 28 Warkentin TE. Agents for the treatment of heparin-induced thrombocytopenia. Hematol Oncol Clin North Am 2010; 24: 755-775.