Spinal evoked responses in the cat. A comparison of different recording techniques with regard to neuromonitoring
Spinale evozierte Potentiale bei der Katze. Vergleich verschiedener Aufzeichnungstechniken und deren Bedeutung für das NeuromonitoringFurther Information
Publication History
Publication Date:
18 March 2008 (online)
Summary
Spinal evoked potentials to sciatic nerve stimulation were recorded with epidural electrodes over the dorsal columns. A comparison with potentials to dorsal column stimulation disclosed differences in the typical segmental variation in regard to wave form, amplitude, spinal conduction velocity and conduction time that could be important in neuromonitoring.
Zusammenfassung
Spinale Potentiale evoziert durch Nervus-Ischiadicus-Reizung und Hinterstrangreizung wurden verglichen. Es fanden sich Unterschiede in Form, Amplitude und spinaler Leitgeschwindigkeit, die für das Neuromonitoring von Bedeutung sein könnten.
Key-Words
cortical evoked response - spinal evoked response - spinal cord conduction velocity - intraoperative monitoring