Z Orthop Unfall 2008; 146(1): 108-113
DOI: 10.1055/s-2007-989334
Knochenzement

© Georg Thieme Verlag KG Stuttgart · New York

In-vitro-Untersuchung unterschiedlicher PMMA-Knochenzemente - ein erster Vergleich neuer Materialien für die Endoprothetik

In Vitro Studies on Various PMMA Bone Cements: A First Comparison of New Materials for ArthroplastyH.-J. Kock1 , 2 , F.-X. Huber2 , J. Hillmeier2 , R. Jäger3 , R. Volkmann4 , A. E. Handschin5 , R. Letsch2 , P.-J. Meeder2
  • 1Klinik für Orthopädische Chirurgie und Unfallchirurgie, Hochtaunus Kliniken gGmbH, Bad Homburg v. d. H.
  • 2Chirurgische Universitätsklinik Heidelberg - Sektion Unfallchirurgie (Ehem. Leiter: Prof. Dr. P.-J. Meeder)
  • 3Fraunhofer Institut für Werkstoffmechanik IWM, Freiburg i. Br.
  • 4Klinik für Unfall- und Wiederherstellungschirurgie, Klinikum Bad Hersfeld
  • 5Klinik für Wiederherstellungschirurgie, Chirurgische Universitätsklinik Zürich, Schweiz
Further Information

Publication History

Publication Date:
18 February 2008 (online)

Zusammenfassung

Studienziel: Klinisch bewährte (Refobacin® Palacos® R und Palacos® R + G) und klinisch noch unerprobte (Refobacin® Bone Cement R und SmartSet® GHV) PMMA-Knochenzemente wurden in vitro auf praxisrelevante Unterschiede getestet. Methode: Hierzu wurden chemische Analysen, Verarbeitungstests und Prüfungen nach der für PMMA-Knochenzemente gültigen ISO-Norm durchgeführt. Ergebnisse: Die ermittelten Ergebnisse zeigen deutliche Hinweise auf die Verwendung unterschiedlicher Copolymere bei Refobacin® Bone Cement R und SmartSet® GHV gegenüber den Palacos®-Zementen. Außerdem zeigten sich signifikant unterschiedliche Viskositätsverläufe und Anteigzeiten (p < 0,01 für Palacos®-Zemente gegenüber Refobacin® Bone Cement R) als Ausdruck eines unterschiedlichen Verarbeitungsverhaltens. Auch die Aushärtezeiten unter ISO-5833-Bedingungen unterschieden sich signifikant (p < 0,01 und p < 0,05 für Palacos®-Zemente gegenüber Refobacin® Bone Cement R, p < 0,01 für Refobacin® Bone Cement R gegenüber SmartSet® GHV). Schlussfolgerung: Angesichts dieser unterschiedlichen Materialcharakteristika können die klinischen Daten aus der Langzeitanwendung der als Standard in der Endoprothetik geltenden Knochenzemente Refobacin® Palacos® R und Palacos® R + G nicht auf die neu entwickelten PMMA-Zemente Refobacin® Bone Cement R und SmartSet® GHV übertragen werden. Vor einer breiten klinischen Anwendung der letzteren Zemente sind zunächst prospektive klinische Studien unter Verwendung der RSA bzw. DEXA-Techniken und in einem zweiten Schritt statistisch aussagekräftige, prospektiv vergleichende Multizenterstudien erforderlich. Bis zum Vorliegen dieser Daten sollten Patienten bei der Anwendung von Refobacin® Bone Cement R und SmartSet® GHV in jedem Fall über die vom Standard der zementierten Endoprothetik in den skandinavischen Prothesenregistern abweichende Materialanwendung mit letztlich unvorhersagbaren Langzeitfolgen aufgeklärt werden um spätere Regressforderungen durch mangelnde Aufklärung zu vermeiden.

Abstract

Aim: Two clinically established PMMA bone cements (Refobacin® Palacos® R and Palacos® R + G) and two newer cements not yet in widespread clinical use (Refobacin® Bone Cement R and SmartSet® GHV) were tested in vitro for practically relevant differences. Methods: The tests included chemical analyses, handling properties and testing according to the ISO standard for PMMA bone cements. Results: The results obtained indicate clearly that the copolymers used in Refobacin® Bone Cement R and SmartSet® GHV differ from those used in the Palacos® cements. There were also significant differences in viscosity behaviour and waiting time (p < 0.01 for Palacos® cements versus Refobacin® Bone Cement R) as an expression of different handling properties. The hardening times under ISO 5833 conditions also differed significantly (p < 0.01 and p < 0.05 for Palacos® cements compared with Refobacin® Bone Cement R and p < 0.01 for Refobacin® Bone Cement R compared with SmartSet® GHV). Conclusion: In view of these differences in material properties, the clinical data from long-term use of the bone cements Refobacin® Palacos® R and Palacos® R + G cannot be extrapolated to the newly developed PMMA cements Refobacin® Bone Cement R and Smart GHV. Before broad clinical use of these cements, prospective clinical studies using RSA or DEXA and, as a second step, statistically powerful prospective comparative studies should be performed. Until these data are available, patients in whom Refobacin® Bone Cement R and SmartSet® GHV are used should be informed that the material employed deviates from the standard procedures for cemented joint replacement in the Scandinavian arthroplasty registers and that the long-term consequences cannot, in the final instance, be foreseen. This is essential in order to avoid later malpractice claims on the grounds of inadequate information.

Literatur

  • 1 Charnley J. Anchorage of the femoral head prosthesis to the shaft of the femur.  J Bone Joint Surg [Br]. 1960;  42 28-30
  • 2 DiMaio F R. The science of bone cement: a historical review.  Orthopedics. 2002;  25 1399-1407
  • 3 Breusch S J, Kühn K D. Knochenzemente auf Basis Polymethylmethacrylat.  Orthopäde. 2003;  32 41-50
  • 4 Linder L. Boneloc - the Christiansen experience revisited.  Acta Orthop Scand. 1995;  66 205-206
  • 5 Nilsson K G, Dalen T. Interferior performance of Boneloc bone cement in total knee arthroplasty. A prospective randomized study comparing Boneloc with Palacos in total knee arthroplasty.  Acta Orthop Scand. 1998;  69 479-483
  • 6 Nilsen A R, Wiig M. Total hip arthroplasty with Boneloc - loosening in 102/157 cases after 0.5-3 years.  Acta Orthop Scand. 1996;  67 57-59
  • 7 Kühn K D. Bone Cements. Heidelberg; Springer 2000: 8-17
  • 8 Brauer G M, Termini D J, Dickson G. Analysis of the ingredients and determination of the residual components of acrylic bone cements.  J Biomed Mater Res. 1977;  11 577-607
  • 9 ISO 5833: Implants for surgery - Acrylic resin cements. 2002
  • 10 Kühn K D, Ege W, Gopp U. Acrylic bone cements: composition and properties.  Orthop Clin North Am. 2005;  36 17-28
  • 11 Lewis G. Relative role of cement molecular weight and mixing method on the fatigue performance of acrylic bone cement: Simplex P versus Osteopal.  J Biomed Mater Res. 2000;  53 119-130
  • 12 Kreutzer J, Schneider M, Schlegel U, Ewerbeck V, Breusch S J. Zementierte Hüftendoprothetik in Deutschland - ein Update.  Z Orthop. 2005;  143 48-55
  • 13 Kühn K D, Ege W, Gopp U. Acrylic bone cements: mechanical and physical properties.  Orthop Clin North Am. 2005;  36 29-39
  • 14 Spierings P TJ. Properties of bone cement: testing and performance of bone cements. Breusch SJ, Malchau H The Well-Cemented Total Hip Arthroplasty. Heidelberg; Springer 2005: 67-78
  • 15 Tanner K E, Mitchell J B. Fatigue testing of Biomet Refobacin Bone Cement R and Refobacin Palacos R Bone Cements. Report of Queen Mary University of London. 8/2006
  • 16 Herberts P, Malchau H. How outcome studies have changed total hip arthroplasty practices in Sweden.  Clin Orthop Rel Res. 1997;  344 44-66
  • 17 Havelin L I, Engesaeter L B, Espehaug B, Furnes O, Lie S A, Vollset S E. The Norwegian Arthroplasty Register: 11 years and 73 000 arthroplasties.  Acta Orthop Scand. 2000;  71 337-353
  • 18 Engesaeter L B, Lie S A, Espehaug B, Furnes O, Vollset S E, Havelin L I. Antibiotic prophylaxis in total hip arthroplasty: effects of antibiotic prophylaxis systemically and in bone cement on the revision rate of 22 170 primary hip replacements followed 0 - 14 years in the Norwegian Arthroplasty Register.  Acta Orthop Scand. 2003;  74 644-651
  • 19 Malchau H, Breusch S J. The future role of cemented total hip arthroplasty. Breusch SJ, Malchau H The Well-Cemented Total Hip Arthroplasty. Heidelberg; Springer 2005: 367-369
  • 20 Abdel-Kader K F, Allcock S, Walker D I, Chaudhry S B. Boneloc bone-cement: experience in hip arthroplasty during a 3-year period.  J Arthroplasty. 2001;  16 811-819

Prof. Dr. Hans-Jürgen Kock

Klinik für Orthopädische Chirurgie und Unfallchirurgie
Hochtaunus Kliniken gGmbH

Urseler Straße 33

61348 Bad Homburg v. d. H.

Phone: 0 61 72/14-31 01

Fax: 0 61 72/14-21 80

Email: hans-juergen.kock@hochtaunus-kliniken.de

    >