Vet Comp Orthop Traumatol 2022; 35(06): 381-389
DOI: 10.1055/s-0042-1750433
Original Research

Accuracy of Lumbosacral Pedicle Screw Placement in Dogs: A Novel 3D Printed Patient-Specific Drill Guide versus Freehand Technique in Novice and Expert Surgeons

1   School of Veterinary Medicine, University of Glasgow, Glasgow, United Kingdom
,
Nathan Wilkinson
2   Axia 3D Design (currently Nexus Engineering & Design Ltd), Napier, New Zealand
,
Manabu Kurihara
3   Cummings School of Veterinary Medicine at Tufts University, Crafton, United States
,
Janis P. Bridges
4   Massey University School of Veterinary Science, Palmerston North, New Zealand
,
Wendy Baltzer
5   University of Sydney, School of Veterinary Science, Sydney, New South Wales, Australia
,
4   Massey University School of Veterinary Science, Palmerston North, New Zealand
› Author Affiliations
Funding Funding for this project was provided by the Massey University Working Dog Centre, Palmerston North, New Zealand.

Abstract

Objective The aim of this study was to compare the accuracy of pedicle screw placement at the canine lumbosacral junction using a novel unilateral three-dimensional printed patient-specific guide (3D-PSG) versus a freehand drilling technique. Additionally, accuracy of screw placement between a novice and an experienced surgeon was determined.

Study Design Preoperative computed tomography images from 20 lumbosacral cadaveric specimens were used to design a novel unilateral 3D-PSG for the L7 and sacral vertebrae which was printed in acryl-nitrile butadiene styrene plastic. A novice and an expert surgeon each placed 3.5mm cortical screws in 10 cadavers; on the left using the unilateral 3D-PSG and by the freehand (anatomic landmark) technique on the right.

Results Sixty screws were placed using the unilateral 3D-PSG and 60 using the freehand technique. There was no statistical difference in accuracy for the comparison between methods performed by the expert (p = 0.679) and novice (p = 0.761) surgeon, nor between an expert and novice surgeon overall (p = 0.923). Unexpectedly, the use of a unilateral 3D-PSG increased variability for the expert surgeon in our study (p = 0.0314).

Conclusion Using a novel unilateral 3D-PSG did not improve the accuracy of screw placement for lumbosacral stabilization by a novice surgeon compared with an expert surgeon in lumbar spine surgery. This may reflect a suboptimal PSG design.



Publication History

Received: 25 January 2021

Accepted: 04 May 2022

Article published online:
10 July 2022

© 2022. Thieme. All rights reserved.

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany

 
  • References

  • 1 Méheust P, Mallet C, Marouze C. A new surgical technique for lumbosacral stabilization: arthrodesis using the pedicle screw fixation. Anatomical aspects. Prat Médicale &amp . Chir l'Animal Cie 2000; 35 (03) 193-199
  • 2 Meij BP, Suwankong N, Van der Veen AJ, Hazewinkel HAW. Biomechanical flexion-extension forces in normal canine lumbosacral cadaver specimens before and after dorsal laminectomy-discectomy and pedicle screw-rod fixation. Vet Surg 2007; 36 (08) 742-751
  • 3 Smolders LA, Voorhout G, van de Ven R. et al. Pedicle screw-rod fixation of the canine lumbosacral junction. Vet Surg 2012; 41 (06) 720-732
  • 4 Chen H, Wu D, Yang H, Guo K. Clinical use of 3D printing guide plate in posterior lumbar pedicle screw fixation. Med Sci Monit 2015; 21: 3948-3954
  • 5 Lu S, Xu YQ, Chen GP. et al. Efficacy and accuracy of a novel rapid prototyping drill template for cervical pedicle screw placement. Comput Aided Surg 2011; 16 (05) 240-248
  • 6 Kraus M, Weiskopf J, Dreyhaupt J, Krischak G, Gebhard F. Computer-aided surgery does not increase the accuracy of dorsal pedicle screw placement in the thoracic and lumbar spine: a retrospective analysis of 2,003 pedicle screws in a level I trauma center. Global Spine J 2015; 5 (02) 93-101
  • 7 Pijpker PAJ, Kraeima J, Witjes MJH. et al. Accuracy assessment of pedicle and lateral mass screw insertion assisted by customized 3D-printed drill guides: a human Cadaver study. Oper Neurosurg (Hagerstown) 2019; 16 (01) 94-102
  • 8 Aoude AA, Fortin M, Figueiredo R, Jarzem P, Ouellet J, Weber MH. Methods to determine pedicle screw placement accuracy in spine surgery: a systematic review. Eur Spine J 2015; 24 (05) 990-1004
  • 9 Yu C, Ou Y, Xie C, Zhang Y, Wei J, Mu X. Pedicle screw placement in spinal neurosurgery using a 3D-printed drill guide template: a systematic review and meta-analysis. J Orthop Surg Res 2020; 15 (01) 1
  • 10 Beer P, Park BH, Steffen F, Smolders DLA, Pozzi A, Knell SC. Influence of a customized three-dimensionally printed drill guide on the accuracy of pedicle screw placement in lumbosacral vertebrae: an ex vivo study. Vet Surg 2020; 49 (05) 977-988
  • 11 Hamilton-Bennett SE, Oxley B, Behr S. Accuracy of a patient-specific 3D printed drill guide for placement of cervical transpedicular screws. Vet Surg 2018; 47 (02) 236-242
  • 12 Guevar J, Bleedorn J, Cullum T, Hetzel S, Zlotnick J, Mariani CL. Accuracy and safety of three-dimensionally printed animal-specific drill guides for thoracolumbar vertebral column instrumentation in dogs: bilateral and unilateral designs. Vet Surg 2021; 50 (02) 336-344
  • 13 Pan Y, Lü GH, Kuang L, Wang B. Accuracy of thoracic pedicle screw placement in adolescent patients with severe spinal deformities: a retrospective study comparing drill guide template with free-hand technique. Eur Spine J 2018; 27 (02) 319-326
  • 14 Garg B, Gupta M, Singh M, Kalyanasundaram D. Outcome and safety analysis of 3D-printed patient-specific pedicle screw jigs for complex spinal deformities: a comparative study. Spine J 2019; 19 (01) 56-64
  • 15 Pu X, Yin M, Ma J. et al. Design and application of a novel patient-specific three-dimensional printed drill navigational guiding in atlantoaxial pedicle screw placement. World Neurosurg 2018; 114: e1-e10
  • 16 Deyo RA, Phillips WR. Low back pain. A primary care challenge. Spine 1996; 21 (24) 2826-2832
  • 17 Worth AJ. Custom titanium implants for stabilisation of the canine lumbosacral joint. Abstract. Veterinary Orthopedic Society, Big Sky, Montana, Feb 28- Mar 3, 2016. Vet Comp Orthop Traumatol 2016; 29 (03) A28
  • 18 Watine S, Cabassu JP, Catheland S, Brochier L, Ivanoff S. Computed tomography study of implantation corridors in canine vertebrae. J Small Anim Pract 2006; 47 (11) 651-657
  • 19 Wheeler S, Sharp N. . Small Animal Spinal Disorders, Diagnosis and Surgery.; 1994. Accessed May 22, 2022 at: https://www.cabdirect.org/cabdirect/abstract/19942214873
  • 20 Rho YH, Cho CW, Ryu CH, Lee JH, Jeong SM, Lee HB. Comparison between novice and experienced surgeons performing corrective osteotomy with patient-specific guides in dogs based on resulting position accuracy. Vet Sci 2021; 8 (03) 1-9
  • 21 Mariani CL, Zlotnick JA, Harrysson O. et al. Accuracy of three-dimensionally printed animal-specific drill guides for implant placement in canine thoracic vertebrae: a cadaveric study. Vet Surg 2021; 50 (02) 294-302
  • 22 Worth AJ. Custom titanium implants for stabilisation of the canine lumbosacral joint. Abstract. Veterinary Orthopedic Society, Big Sky, Montana, Feb 28- Mar 3, 2016. Vet Comp Orthop Traumatol 2016; 29 (03) A28
  • 23 Kaneyama S, Sugawara T, Sumi M. Safe and accurate midcervical pedicle screw insertion procedure with the patient-specific screw guide template system. Spine 2015; 40 (06) E341-E348
  • 24 Yu CC, Yuh RT, Bajwa NS, Toy JO, Ahn UM, Ahn NU. Pedicle morphometry of lumbar vertebrae: male, taller, and heavier specimens have bigger pedicles. Spine 2015; 40 (21) 1639-1646
  • 25 Mohanty SP, Pai Kanhangad M, Bhat SP. et al Morphometry of the lower thoracic and lumbar pedicles and its relevance in pedicle fixation. Musculoskelet Surg 2018; 102: 299-305
  • 26 Cartiaux O, Jenny JY, Joskowicz L. Accuracy of computer-aided techniques in orthopaedic surgery: how can it be defined, measured experimentally, and analyzed from a clinical perspective?. J Bone Joint Surg Am 2017; 99 (08) e39
  • 27 Toni C, Oxley B, Clarke S, Behr S. Accuracy of placement of pedicle screws in the lumbosacral region of dogs using 3D-printed patient-specific drill guides. Vet Comp Orthop Traumatol 2021; 34 (01) 53-58
  • 28 Lien SB, Liou NH, Wu S-S. Analysis of anatomic morphometry of the pedicles and the safe zone for through-pedicle procedures in the thoracic and lumbar spine. Eur Spine J 2007; 16: 1215-1222
  • 29 Toni C, Oxley B, Behr S. Atlanto-axial ventral stabilisation using 3D-printed patient-specific drill guides for placement of bicortical screws in dogs. J Small Anim Pract 2020; 61 (10) 609-616
  • 30 Elford JH, Oxley B, Behr S. Accuracy of placement of pedicle screws in the thoracolumbar spine of dogs with spinal deformities with three-dimensionally printed patient-specific drill guides. Vet Surg 2020; 49 (02) 347-353
  • 31 Fujioka T, Nakata K, Nakano Y. et al. Accuracy and efficacy of a patient-specific drill guide template system for lumbosacral junction fixation in medium and small dogs: cadaveric study and clinical cases. Front Vet Sci 2020; 6: 494
  • 32 Dorweiler B, Baqué PE, Chaban R, Ghazy A, Salem O. Quality control in 3D printing: accuracy analysis of 3D-printed models of patient-specific anatomy. Materials (Basel) 2021; 14 (04) 1-13
  • 33 Wen Z, Lu T, He X. et al. Accuracy of cervical pedicle screw placement with four different designs of rapid prototyping navigation templates: a human cadaveric study. Comput Assist Surg (Abingdon) 2021; 26 (01) 49-57
  • 34 Spirig JM, Golshani S, Farshad-Amacker NA, Farshad M. Patient-specific template-guided versus standard freehand lumbar pedicle screw implantation: a randomized controlled trial. J Neurosurg Spine 2021; ; (May): 1-7
  • 35 Wang VY, Chin CT, Lu DC. et al. Free-hand thoracic pedicle screws placed by neurosurgery residents: a CT analysis. Eur Spine J 2010; 19: 821-827