J Knee Surg 2023; 36(09): 988-994
DOI: 10.1055/s-0042-1748899
Original Article

Metal Artifact Reduction Dual-Energy CT as an Accurate and Reliable Method for Measuring Total Knee Arthroplasty Femoral Component Rotation Compared to Conventional CT

Chankue Park
1   Department of Radiology, Pusan National University – Yangsan Hospital, Yangsan, Korea
2   Research Institute for Convergence of Biomedical Science and Technology, Pusan National University School of Medicine, Yangsan, Korea
,
2   Research Institute for Convergence of Biomedical Science and Technology, Pusan National University School of Medicine, Yangsan, Korea
3   Department of Orthopaedic Surgery, Pusan National University – Yangsan Hospital, Yangsan, Korea
,
Jae Seung Seo
3   Department of Orthopaedic Surgery, Pusan National University – Yangsan Hospital, Yangsan, Korea
,
Tae Woo Kim
2   Research Institute for Convergence of Biomedical Science and Technology, Pusan National University School of Medicine, Yangsan, Korea
3   Department of Orthopaedic Surgery, Pusan National University – Yangsan Hospital, Yangsan, Korea
,
Seung Joon Rhee
2   Research Institute for Convergence of Biomedical Science and Technology, Pusan National University School of Medicine, Yangsan, Korea
4   Department of Orthopedic Surgery, Pusan National University Hospital, Busan, Korea
,
Hee Seok Jeong
1   Department of Radiology, Pusan National University – Yangsan Hospital, Yangsan, Korea
2   Research Institute for Convergence of Biomedical Science and Technology, Pusan National University School of Medicine, Yangsan, Korea
› Author Affiliations
Funding This study was supported by Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital (30-2021-009)

Abstract

This article determines the accuracy and reliability of dual-energy computed tomography (DECT) with metal artifact reduction (MAR) in the evaluation of femoral component rotation after total knee arthroplasty (TKA), in comparison with conventional CT images. A total of 49 patients (mean age, 69 years; 42 women) who underwent TKA between January 2019 and March 2020 were retrospectively enrolled. Femoral component rotation, including the anatomic and surgical transepicondylar axes, was evaluated with preoperative conventional CT and postoperative conventional CT and DECT with MAR. Surgical femoral component rotation was also assessed as a reference standard. Accuracy was assessed using paired t-test, and inter- and intraobserver reliability using intraclass correlation coefficients (ICCs) based on postoperative conventional CT and DECT with MAR. Clinical outcomes were evaluated using the Knee Society objective and functional scores. Accuracy of femoral component rotation was not significantly different from that of surgical rotation with both conventional CT and DECT with MAR. However, inter- and intraobserver reliability were better for DECT with MAR (ICC: 0.953–0.966) than for conventional CT (ICC: 0.641–0.749). The Knee Society objective and functional scores improved 1 year postoperatively.

Conclusion DECT with MAR showed accurate and more reliable results than did conventional CT in the evaluation of femoral component rotation after TKA.



Publication History

Received: 27 September 2021

Accepted: 18 March 2022

Article published online:
12 July 2022

© 2022. Thieme. All rights reserved.

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

 
  • References

  • 1 Insall J, Ranawat CS, Scott WN, Walker P. Total condylar knee replacement: preliminary report. Clin Orthop Relat Res 1976; (120) 149-154
  • 2 Kurtz S, Ong K, Lau E, Mowat F, Halpern M. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am 2007; 89 (04) 780-785
  • 3 Sharkey PF, Hozack WJ, Rothman RH, Shastri S, Jacoby SM. Insall Award paper. Why are total knee arthroplasties failing today?. Clin Orthop Relat Res 2002; (404) 7-13
  • 4 Hirschmann MT, Konala P, Amsler F, Iranpour F, Friederich NF, Cobb JP. The position and orientation of total knee replacement components: a comparison of conventional radiographs, transverse 2D-CT slices and 3D-CT reconstruction. J Bone Joint Surg Br 2011; 93 (05) 629-633
  • 5 Park CH, Song SJ. Sensor-assisted total knee arthroplasty: a narrative review. Clin Orthop Surg 2021; 13 (01) 1-9
  • 6 Valkering KP, Breugem SJ, van den Bekerom MP, Tuinebreijer WE, van Geenen RCI. Effect of rotational alignment on outcome of total knee arthroplasty. Acta Orthop 2015; 86 (04) 432-439
  • 7 Fosco M, Rimondi E, Amendola L, Rossi G, Tigani D. Revision of knee prostheses with components malrotation: treatment algorithm using a computed tomographic analysis. Eur Orthop Traumatol 2010; 1: 61-68
  • 8 Feiock DA, Newman JS, Newberg AH. Radiological evaluation of total knee arthroplasty. In: Bono JV, Scott RD. eds. Revision Total Knee Arthroplasty. New York: Springer; 2005: 36-52
  • 9 Katsura M, Sato J, Akahane M, Kunimatsu A, Abe O. Current and novel techniques for metal artifact reduction at CT: practical guide for radiologists. Radiographics 2018; 38 (02) 450-461
  • 10 Konigsberg B, Hess R, Hartman C, Smith L, Garvin KL. Inter- and intraobserver reliability of two-dimensional CT scan for total knee arthroplasty component malrotation. Clin Orthop Relat Res 2014; 472 (01) 212-217
  • 11 Kim J, Park C, Jeong HS. et al. The optimal combination of monochromatic and metal artifact reconstruction dual-energy CT to evaluate total knee replacement arthroplasty. Eur J Radiol 2020; 132: 109254
  • 12 Victor J. Rotational alignment of the distal femur: a literature review. Orthop Traumatol Surg Res 2009; 95 (05) 365-372
  • 13 Kim JM, Kim SB, Kim JM, Lee DH, Lee BS, Bin SI. Results of gender-specific total knee arthroplasty: comparative study with traditional implant in female patients. Knee Surg Relat Res 2015; 27 (01) 17-23
  • 14 Choi Y, Koo J, Moon SW, Yang Y, Son J. Long-term follow-up of patellar nonresurfacing in total knee arthroplasty. Clin Orthop Surg 2020; 12 (01) 49-54
  • 15 Moro-oka TA, Shiraishi H, Iwamoto Y, Banks SA. Modified gap-balancing technique in total knee arthroplasty: evaluation of the post-operative coronal laxity. Knee Surg Sports Traumatol Arthrosc 2010; 18 (03) 375-380
  • 16 Lee WC, Kwan YH, Chong HC, Yeo SJ. The minimal clinically important difference for Knee Society Clinical Rating System after total knee arthroplasty for primary osteoarthritis. Knee Surg Sports Traumatol Arthrosc 2017; 25 (11) 3354-3359
  • 17 Harris JD, Brand JC, Cote MP, Faucett SC, Dhawan A. Research pearls: the significance of statistics and perils of pooling. Part 1: clinical versus statistical significance. Arthroscopy 2017; 33 (06) 1102-1112
  • 18 Berger RA, Rubash HE, Seel MJ, Thompson WH, Crossett LS. Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res 1993; (286) 40-47
  • 19 Wang Y, Qian B, Li B. et al. Metal artifacts reduction using monochromatic images from spectral CT: evaluation of pedicle screws in patients with scoliosis. Eur J Radiol 2013; 82 (08) e360-e366
  • 20 Wang F, Xue H, Yang X. et al. Reduction of metal artifacts from alloy hip prostheses in computer tomography. J Comput Assist Tomogr 2014; 38 (06) 828-833
  • 21 Cha J, Kim HJ, Kim ST, Kim YK, Kim HY, Park GM. Dual-energy CT with virtual monochromatic images and metal artifact reduction software for reducing metallic dental artifacts. Acta Radiol 2017; 58 (11) 1312-1319
  • 22 Neuhaus V, Große Hokamp N, Abdullayev N. et al. Metal artifact reduction by dual-layer computed tomography using virtual monoenergetic images. Eur J Radiol 2017; 93: 143-148