J Hand Microsurg 2023; 15(04): 318-321
DOI: 10.1055/s-0042-1748762
Case Report

Metallosis Following Titanium Implant Use in the Hand: A Case Report and Review of Current Literature

1   Department of Hand and Reconstructive Microsurgery, Tan Tock Seng Hospital, Singapore
,
Khoon Leong Chuah
2   Department of Pathology, Tan Tock Seng Hospital, Singapore
,
Lam Chuan Teoh
1   Department of Hand and Reconstructive Microsurgery, Tan Tock Seng Hospital, Singapore
› Author Affiliations
Funding None.

Abstract

Adverse reaction to metal debris (ARMD) consists of a spectrum of changes ranging from pure metallosis to aseptic lymphocytic vasculitis-associated lesion and granulomatous inflammation. Currently described ARMD cases are mainly limited to arthroplasty, typically total hip and knee arthroplasties in the lower limb and total wrist arthroplasty in the upper limb. Hypersensitivity to a metallic implant in fracture fixation is rare, and a severe form of metallosis has not been reported so far. In this paper, we present a case of ARMD occurring 10 years after the use of titanium implants for fracture fixation in the hand. Intra-operative findings, histopathological results, and a literature review on ARMD are also described.



Publication History

Article published online:
28 June 2022

© 2022. Society of Indian Hand Surgery & Microsurgeons. All rights reserved.

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

 
  • References

  • 1 Willert HG, Buchhorn GH, Fayyazi A. et al. Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am 2005; 87 (01) 28-36
  • 2 Natu S, Sidaginamale RP, Gandhi J, Langton DJ, Nargol AV. Adverse reactions to metal debris: histopathological features of periprosthetic soft tissue reactions seen in association with failed metal on metal hip arthroplasties. J Clin Pathol 2012; 65 (05) 409-418
  • 3 Kudo H, Iwano K, Nishino J. Cementless or hybrid total elbow arthroplasty with titanium-alloy implants. A study of interim clinical results and specific complications. J Arthroplasty 1994; 9 (03) 269-278
  • 4 La Budde JK, Orosz JF, Bonfiglio TA, Pellegrini Jr VD. Particulate titanium and cobalt-chrome metallic debris in failed total knee arthroplasty. A quantitative histologic analysis. J Arthroplasty 1994; 9 (03) 291-304
  • 5 Radmer S, Andresen R, Sparmann M. Total wrist arthroplasty in patients with rheumatoid arthritis. J Hand Surg Am 2003; 28 (05) 789-794
  • 6 Heyes GJ, Julian HS, Mawhinney I. Metallosis and carpal tunnel syndrome following total wrist arthroplasty. J Hand Surg Eur Vol 2018; 43 (04) 448-450
  • 7 Tang JB, Giddins G. Why and how to report surgeons' levels of expertise. J Hand Surg Eur Vol 2016; 41 (04) 365-366
  • 8 Cipriano CA, Issack PS, Beksac B, Valle AGD, Sculco TP, Salvati EA. Metallosis after metal-on-polyethylene total hip arthroplasty. Am J Orthop 2008; 37 (02) E18-E25
  • 9 Mao X, Tay GH, Godbolt DB, Crawford RW. Pseudotumor in a well-fixed metal-on-polyethylene uncemented hip arthroplasty. J Arthroplasty 2012; 27 (03) 493.e13-493.e17
  • 10 Cooper HJ, Urban RM, Wixson RL, Meneghini RM, Jacobs JJ. Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck. J Bone Joint Surg Am 2013; 95 (10) 865-872
  • 11 Cooper HJ, Valle CJD, Berger RA. et al. Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty. J Bone Joint Surg Am 2012; 94 (18) 1655-1661
  • 12 Cook SD, Barrack RL, Baffes GC. et al. Wear and corrosion of modular interfaces in total hip replacements. Clin Orthop Relat Res 1994; Jan (298) 80-88
  • 13 Fage SW, Muris J, Jakobsen SS, Thyssen JP. Titanium: a review on exposure, release, penetration, allergy, epidemiology, and clinical reactivity. Contact Dermat 2016; 74 (06) 323-345
  • 14 Kheder W, Al Kawas S, Khalaf K, Samsudin AR. Impact of tribocorrosion and titanium particles release on dental implant complications—a narrative review. Jpn Dent Sci Rev 2021; 57: 182-189
  • 15 Lehtovirta L, Reito A, Lainiala O. et al. Host-specific factors affect the pathogenesis of adverse reaction to metal debris. BMC Musculoskelet Disord 2019; 20 (01) 195
  • 16 Plummer DR, Berger RA, Paprosky WG, Sporer SM, Jacobs JJ, Valle CJD. Diagnosis and management of adverse local tissue reactions secondary to corrosion at the head-neck junction in patients with metal on polyethylene bearings. J Arthroplasty 2016; 31 (01) 264-268
  • 17 Maloney E, Ha AS, Miller TT. Imaging of adverse reactions to metal debris. Semin Musculoskelet Radiol 2015; 19 (01) 21-30
  • 18 Christensen TJ, Samant SA, Shin AY. Making sense of metal allergy and hypersensitivity to metallic implants in relation to hand surgery. J Hand Surg Am 2017; 42 (09) 737-746