Vet Comp Orthop Traumatol 2022; 35(03): 166-174
DOI: 10.1055/s-0042-1744175
Original Research

Biomechanical Comparison of Use of Two Screws versus Three Screws Per Fragment with Locking Plate Constructs under Cyclic Loading in Compression in a Fracture Gap Model

1   Université de Toulouse, ENVT, Toulouse, France
,
1   Université de Toulouse, ENVT, Toulouse, France
,
Pascal Swider
2   Université de Toulouse, IMFT UMR 5502, Toulouse, France
,
1   Université de Toulouse, ENVT, Toulouse, France
› Author Affiliations
Funding None.

Abstract

Objectives The aim of this study was to measure and compare the stiffness and cyclic fatigue of two plate-bone model constructs, with either two or three locking screws per fragment, under cyclic compression.

Methods A 10-hole 3.5 mm stainless steel locking compression plate (LCP) was fixed 1 mm from a synthetic bone model in which the fracture gap was 47 mm. Two groups of 10 constructs, prepared with either two or three bicortical locking screws placed at the extremities of each fragment, were tested in a load-controlled compression test until failure.

Results The three-screw constructs were stiffer than the two-screw constructs (196.75 ± 50.48 N/mm and 102.43 ± 22.93 N/mm, respectively) and the actuator displacements of the two-screw constructs were higher (18.02 ± 1.07 mm) than those of the three-screw constructs (14.48 ± 2.25 mm). The number of cycles to failure of the two-screw constructs was significantly lower (38,337.50 ± 2,196.98) than the that of the three-screw constructs (44,224.00 ± 1,515.24). Load at irreversible deformation was significantly lower in the two-screw constructs (140.93 ± 13.39 N) than in the three-screw constructs (184.27 ± 13.17 N). All constructs failed by plate bending at the gap between the two cylinders.

Clinical Significance Omission of the third innermost locking screw during bridging osteosynthesis subjected to compression forces led to a 13.3% reduction in the number of cycles to failure and a 23.5% reduction of the load withstood by the plate before plastic deformation occurred.

Author's Contribution

S.P. and A.A. were the primary investigators, adapted the study concept and design, performed data collection, data analysis and statistical analysis and wrote the manuscript. P.S. helped for setup of the study concept and design and critical review of the manuscript. M.B. helped with data collection as well as data analysis and and critical review of the manuscript. All authors agree to be publicly accountable for the content of the manuscript.




Publication History

Received: 18 May 2021

Accepted: 27 January 2022

Article published online:
10 March 2022

© 2022. Thieme. All rights reserved.

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany

 
  • References

  • 1 Johnson AL, Houlton JEF, Vannini R. AO Principles of Fracture Management in the Dog and Cat. First edition. Stuttgart, New-York: Thieme; 2005: 529
  • 2 Moores AP. Biomechanical basis of bone fracture and fracture repair. In: Gemmill TJ, Clements DN. eds. BSAVA Manual of Canine and Feline Fracture Repair and Management. Second edition. British Small Animal Veterinary Association; Gloucester, UK: 2016: 20-30
  • 3 Roe S. Biomechanics of fracture fixation. Vet Clin North Am Small Anim Pract 2020; 50 (01) 1-15
  • 4 Gautier E, Sommer C. Guidelines for the clinical application of the LCP. Injury 2003; 34 (Suppl. 02) B63-B76
  • 5 Stoffel K, Dieter U, Stachowiak G, Gächter A, Kuster MS. Biomechanical testing of the LCP–how can stability in locked internal fixators be controlled?. Injury 2003; 34 (Suppl. 02) B11-B19
  • 6 Taylor WR, Ehrig RM, Heller MO, Schell H, Seebeck P, Duda GN. Tibio-femoral joint contact forces in sheep. J Biomech 2006; 39 (05) 791-798
  • 7 Bird G, Glyde M, Hosgood G, Hayes A, Day R. Biomechanical comparison of a notched head locking T-plate and a straight locking compression plate in a juxta-articular fracture model. Vet Comp Orthop Traumatol 2021; 34 (03) 161-170
  • 8 Field EJ, Parsons K, Etches JA, Hamilton K, Burton NJ. Effect of monocortical and bicortical screw numbers on the properties of a locking plate-intramedullary rod configuration. An in vitro study on a canine femoral fracture gap model. Vet Comp Orthop Traumatol 2016; 29 (06) 459-465
  • 9 Gutbrod A, Vincenti S, Kühn K, Knell SC, Schmierer PA, Pozzi A. An anatomical study of plate-rod fixation in feline tibiae. Vet Surg 2017; 46 (07) 909-914
  • 10 Pearson T, Glyde M, Hosgood G, Day R. The effect of intramedullary pin size and monocortical screw configuration on locking compression plate-rod constructs in an in vitro fracture gap model. Vet Comp Orthop Traumatol 2015; 28 (02) 95-103
  • 11 Bilmont A, Palierne S, Verset M, Swider P, Autefage A. Biomechanical comparison of two locking plate constructs under cyclic torsional loading in a fracture gap model. Two screws versus three screws per fragment. Vet Comp Orthop Traumatol 2015; 28 (05) 323-330
  • 12 Palierne S, Froidefond B, Swider P, Autefage A. Biomechanical comparison of two locking plate constructs under cyclic loading in four-point bending in a fracture gap model - two screws versus three screws per fragment. Vet Comp Orthop Traumatol 2019; 32 (01) 59-66
  • 13 Tomlinson AW, Comerford EJ, Birch RS, Innes JF, Walton MB. Mechanical performance in axial compression of a titanium polyaxial locking plate system in a fracture gap model. Vet Comp Orthop Traumatol 2015; 28 (02) 88-94
  • 14 Windolf M, Klos K, Wähnert D. et al. Biomechanical investigation of an alternative concept to angular stable plating using conventional fixation hardware. BMC Musculoskelet Disord 2010; 11: 95
  • 15 Ahmad M, Nanda R, Bajwa AS, Candal-Couto J, Green S, Hui AC. Biomechanical testing of the locking compression plate: when does the distance between bone and implant significantly reduce construct stability?. Injury 2007; 38 (03) 358-364
  • 16 Bottlang M, Feist F. Biomechanics of far cortical locking. J Orthop Trauma 2011; 25 (Suppl. 01) S21-S28
  • 17 Bottlang M, Lesser M, Koerber J. et al. Far cortical locking can improve healing of fractures stabilized with locking plates. J Bone Joint Surg Am 2010; 92 (07) 1652-1660
  • 18 Filipowicz D, Lanz O, McLaughlin R, Elder S, Werre S. A biomechanical comparison of 3.5 locking compression plate fixation to 3.5 limited contact dynamic compression plate fixation in a canine cadaveric distal humeral metaphyseal gap model. Vet Comp Orthop Traumatol 2009; 22 (04) 270-277
  • 19 Irubetagoyena I, Verset M, Palierne S, Swider P, Autefage A. Ex vivo cyclic mechanical behaviour of 2.4 mm locking plates compared with 2.4 mm limited contact plates in a cadaveric diaphyseal gap model. Vet Comp Orthop Traumatol 2013; 26 (06) 479-488
  • 20 Morris AP, Anderson AA, Barnes DM. et al. Plate failure by bending following tibial fracture stabilisation in 10 cats. J Small Anim Pract 2016; 57 (09) 472-478
  • 21 Schwandt CS, Montavon PM. Locking compression plate fixation of radial and tibial fractures in a young dog. Vet Comp Orthop Traumatol 2005; 18 (03) 194-198
  • 22 MacLeod A, Simpson AHRW, Pankaj P. Experimental and numerical investigation into the influence of loading conditions in biomechanical testing of locking plate fracture fixation devices. Bone Joint Res 2018; 7 (01) 111-120
  • 23 Bottlang M, Doornink J, Byrd GD, Fitzpatrick DC, Madey SM. A nonlocking end screw can decrease fracture risk caused by locked plating in the osteoporotic diaphysis. J Bone Joint Surg Am 2009; 91 (03) 620-627
  • 24 Bottlang M, Doornink J, Fitzpatrick DC, Madey SM. Far cortical locking can reduce stiffness of locked plating constructs while retaining construct strength. J Bone Joint Surg Am 2009; 91 (08) 1985-1994
  • 25 Brückner M, Unger M, Spies M. In vitro biomechanical comparison of a newly designed interlocking nail system to a standard DCP. Testing of cat femora in an osteotomy gap model. Tierarztl Prax Ausg K Klientiere Heimtiere 2014; 42 (02) 79-87
  • 26 Doornink J, Fitzpatrick DC, Boldhaus S, Madey SM, Bottlang M. Effects of hybrid plating with locked and nonlocked screws on the strength of locked plating constructs in the osteoporotic diaphysis. J Trauma 2010; 69 (02) 411-417
  • 27 Grawe B, Le T, Williamson S, Archdeacon A, Zardiackas L. Fracture fixation with two locking screws versus three non-locking screws: a biomechanical comparison in a normal and an osteoporotic bone model. Bone Joint Res 2012; 1 (06) 118-124
  • 28 Chao P, Conrad BP, Lewis DD, Horodyski M, Pozzi A. Effect of plate working length on plate stiffness and cyclic fatigue life in a cadaveric femoral fracture gap model stabilized with a 12-hole 2.4 mm locking compression plate. BMC Vet Res 2013; 9 (01) 125
  • 29 Hoffmeier KL, Hofmann GO, Mückley T. Choosing a proper working length can improve the lifespan of locked plates. A biomechanical study. Clin Biomech (Bristol, Avon) 2011; 26 (04) 405-409
  • 30 Maxwell M, Horstman CL, Crawford RL, Vaughn T, Elder S, McLaughlin R. The effects of screw placement on plate strain in 3.5 mm dynamic compression plates and limited-contact dynamic compression plates. Vet Comp Orthop Traumatol 2009; 22 (02) 125-131
  • 31 Sanders R, Haidukewych GJ, Milne T, Dennis J, Latta LL. Minimal versus maximal plate fixation techniques of the ulna: the biomechanical effect of number of screws and plate length. J Orthop Trauma 2002; 16 (03) 166-171
  • 32 Claes L. Biomechanical principles and mechanobiologic aspects of flexible and locked plating. J Orthop Trauma 2011; 25 (Suppl. 01) S4-S7
  • 33 DeCamp CE, Johnston SA, Déjardin LM. Brinker, Piermattei and Flo's Handbook of Small Animal Orthopaedics and Fracture Repair. 5th edition. St. Louis, Missouri: Elsevier; 2016: 880
  • 34 Windolf M, Ernst M, Schwyn R. et al, Eds. A Biofeedback System for Continuous Monitoring of Bone Healing. BIODEVICES. Angers, Loire Valley, France: 2014: 243-248
  • 35 Windolf M, Ernst M, Schwyn R, Arens D, Zeiter S. The relation between fracture activity and bone healing with special reference to the early healing phase - a preclinical study. Injury 2021; 52 (01) 71-77
  • 36 Grasa J, Gómez-Benito MJ, González-Torres LA, Asiaín D, Quero F, García-Aznar JM. Monitoring in vivo load transmission through an external fixator. Ann Biomed Eng 2010; 38 (03) 605-612
  • 37 Gomes GS, Zderic I, Ahrend MD. et al. Is bridge plating of comminuted humeral shaft fractures advantageous when using compression plates with three versus two screws per fragment? A biomechanical cadaveric study. BioMed Res Int 2021; 2021: 6649712
  • 38 Hak DJ, Althausen P, Hazelwood SJ. Locked plate fixation of osteoporotic humeral shaft fractures: are two locking screws per segment enough?. J Orthop Trauma 2010; 24 (04) 207-211