J Neurol Surg A Cent Eur Neurosurg 2022; 83(06): 588-595
DOI: 10.1055/s-0041-1731754
Technical Note

Optimized Intraoperative Imaging for Stereotactic Planning with a Multiaxial Robotic C-arm System: Technical Note and Case Series

Frederik Enders
1   Department of Neurosurgery, University Hospital Mannheim, Mannheim, Germany
,
Andreas Rothfuss
2   Fraunhofer IPA Mannheim - Fraunhofer-Projektgruppe für Automatisierung in der Medizin und Biotechnologie PAMB, Mannheim, Germany
,
Stefanie Brehmer
1   Department of Neurosurgery, University Hospital Mannheim, Mannheim, Germany
,
Jan Stallkamp
2   Fraunhofer IPA Mannheim - Fraunhofer-Projektgruppe für Automatisierung in der Medizin und Biotechnologie PAMB, Mannheim, Germany
,
Dirk Michael Schulte
1   Department of Neurosurgery, University Hospital Mannheim, Mannheim, Germany
,
Daniel Hänggi
1   Department of Neurosurgery, University Hospital Mannheim, Mannheim, Germany
3   Department of Neurosurgery, University Hospital Dusseldorf, Dusseldorf, Nordrhein-Westfalen, Germany
› Author Affiliations

Abstract

Background The preoperative preparation of the planning dataset for frame-based stereotactic brain biopsy is often associated with logistical effort and burden on the patient. Intraoperative imaging modalities need to be investigated to overcome these limitations.

Objective The objective of the study was to develop and apply a new method for the intraoperative acquisition of the planning dataset with the multiaxial robotic C-arm system Artis zeego.

Methods An indication-customized dose-reduced protocol for Artis zeego was developed and implemented into the workflow. A sample of 14 patients who had undergone intraoperative imaging with Artis zeego was analyzed. A sample of 10 patients with conventional preoperative imaging by cranial computed tomography (CT) was used as a control group. Outcomes were compared with regard to target deviation, diagnostic value of the biopsies, complications, and procedure time.

Results In all patients, a suitable intraoperative planning dataset could be acquired with Artis zeego. Total procedure time was shorter for the Artis zeego group (p = 0.01), whereas time in the operating room area was longer in the Artis zeego group (p = 0.04). Biopsy results were diagnostic in 12 patients (86%) in the Artis zeego group and in 8 patients (80%) in the control group. There were no significant differences in target size, trajectory length, or target deviation.

Conclusion Intraoperative imaging for frame-based stereotactic brain biopsy with Artis zeego is an easy and feasible method. Accuracy is comparable to conventional CT, whereas radiation exposure could be additionally reduced. It allows a significant reduction of the total procedure length and improves the comfort for the patient and staff.



Publication History

Received: 21 August 2020

Accepted: 21 January 2021

Article published online:
15 November 2021

© 2021. Thieme. All rights reserved.

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany

 
  • References

  • 1 Skjøth-Rasmussen J, Jespersen B, Brennum J. The use of Brainsuite iCT for frame-based stereotactic procedures. Acta Neurochir (Wien) 2015; 157 (08) 1437-1440 , discussion 1440
  • 2 Boland JE, Wang LW, Love BJ, Christofi M, Muller DW. Impact of new-generation hybrid imaging technology on radiation dose during percutaneous coronary interventions and trans-femoral aortic valve implantations: a comparison with conventional flat-plate angiography. Heart Lung Circ 2016; 25 (07) 668-675
  • 3 Hsieh MJ, Fang HY, Lin CC, Wen CT, Chen HW, Chao YK. Single-stage localization and removal of small lung nodules through image-guided video-assisted thoracoscopic surgery. Eur J Cardiothorac Surg 2017
  • 4 Rotter N, Schmitz B, Sommer F. et al. First use of flat-panel computed tomography during cochlear implant surgery: perspectives for the use of advanced therapies in cochlear implantation. HNO 2017; 65 (01) 61-65
  • 5 Cordemans V, Kaminski L, Banse X, Francq BG, Cartiaux O. Accuracy of a new intraoperative cone beam CT imaging technique (Artis zeego II) compared to postoperative CT scan for assessment of pedicle screws placement and breaches detection. Eur Spine J 2017; 26 (11) 2906-2916
  • 6 Delavallée M, Delaunois J, Ruwet J, Jeanjean A, Raftopoulos C. STN DBS for Parkinson's disease: results from a series of ten consecutive patients implanted under general anaesthesia with intraoperative use of 3D fluoroscopy to control lead placement. Acta Neurochir (Wien) 2016; 158 (09) 1783-1788
  • 7 Yuen J, Zhu CX, Chan DT. et al. A sequential comparison on the risk of haemorrhage with different sizes of biopsy needles for stereotactic brain biopsy. Stereotact Funct Neurosurg 2014; 92 (03) 160-169
  • 8 Poca MA, Martínez-Ricarte FR, Gándara DF, Coscojuela P, Martínez-Sáez E, Sahuquillo J. Target location after deep cerebral biopsies using low-volume air injection in 75 patients. Results and technical note. Acta Neurochir (Wien) 2017; 159 (10) 1939-1946
  • 9 Bradac O, Steklacova A, Nebrenska K, Vrana J, de Lacy P, Benes V. Accuracy of VarioGuide frameless stereotactic system against frame-based stereotaxy: prospective, randomized, single-center study. World Neurosurg 2017; 104: 831-840
  • 10 Kelman C, Ramakrishnan V, Davies A, Holloway K. Analysis of stereotactic accuracy of the Cosman-Robert-Wells frame and Nexframe frameless systems in deep brain stimulation surgery. Stereotact Funct Neurosurg 2010; 88 (05) 288-295
  • 11 Lunsford LD, Niranjan A, Khan AA, Kondziolka D. Establishing a benchmark for complications using frame-based stereotactic surgery. Stereotact Funct Neurosurg 2008; 86 (05) 278-287
  • 12 Shakal AA, Mokbel EA. Hemorrhage after stereotactic biopsy from intra-axial brain lesions: incidence and avoidance. J Neurol Surg A Cent Eur Neurosurg 2014; 75 (03) 177-182
  • 13 Grossman R, Sadetzki S, Spiegelmann R, Ram Z. Haemorrhagic complications and the incidence of asymptomatic bleeding associated with stereotactic brain biopsies. Acta Neurochir (Wien) 2005; 147 (06) 627-631 , discussion 631
  • 14 Kulkarni AV, Guha A, Lozano A, Bernstein M. Incidence of silent hemorrhage and delayed deterioration after stereotactic brain biopsy. J Neurosurg 1998; 89 (01) 31-35
  • 15 Khaldi A, Prabhu VC, Anderson DE, Origitano TC. The clinical significance and optimal timing of postoperative computed tomography following cranial surgery. J Neurosurg 2010; 113 (05) 1021-1025
  • 16 Berris T, Gupta R, Rehani MM. Radiation dose from cone-beam CT in neuroradiology applications. AJR Am J Roentgenol 2013; 200 (04) 755-761
  • 17 Woodworth GF, McGirt MJ, Samdani A, Garonzik I, Olivi A, Weingart JD. Frameless image-guided stereotactic brain biopsy procedure: diagnostic yield, surgical morbidity, and comparison with the frame-based technique. J Neurosurg 2006; 104 (02) 233-237
  • 18 Livermore LJ, Ma R, Bojanic S, Pereira EA. Yield and complications of frame-based and frameless stereotactic brain biopsy: the value of intra-operative histological analysis. Br J Neurosurg 2014; 28 (05) 637-644
  • 19 Fomenko A, Serletis D. Robotic stereotaxy in cranial neurosurgery: a qualitative systematic review. Neurosurgery 2017
  • 20 Lu Y, Yeung C, Radmanesh A, Wiemann R, Black PM, Golby AJ. Comparative effectiveness of frame-based, frameless, and intraoperative magnetic resonance imaging-guided brain biopsy techniques. World Neurosurg 2015; 83 (03) 261-268
  • 21 Lefranc M, Capel C, Pruvot-Occean AS. et al. Frameless robotic stereotactic biopsies: a consecutive series of 100 cases. J Neurosurg 2015; 122 (02) 342-352