J Hand Microsurg 2023; 15(02): 116-123
DOI: 10.1055/s-0041-1729439
Original Article

Treatment of Distal Radius Fractures in Women Older than 80 Years: A Preliminary Report of Functional and Radiographic Outcomes after Open Reduction and Internal Fixation

Lili E. Schindelar
1   Rothman Orthopaedics, Philadelphia, Pennsylvania, United States
,
Richard M. McEntee
2   Sidney Kimmel Medical College at Thomas Jefferson University, Philadelphia, Pennsylvania, United States
,
Robert E. Gallivan
2   Sidney Kimmel Medical College at Thomas Jefferson University, Philadelphia, Pennsylvania, United States
,
Brian Katt
1   Rothman Orthopaedics, Philadelphia, Pennsylvania, United States
,
Pedro K. Beredjiklian
1   Rothman Orthopaedics, Philadelphia, Pennsylvania, United States
› Author Affiliations

Abstract

Background Distal radius fractures are one of the most common fractures seen in the elderly. The management of distal radius fractures in the elderly, especially patients older than 80 years, has not been well defined. The purpose of this study was to evaluate operative treatment of distal radius fractures in patients older than 80 years to determine functional outcomes and complication rates.

Materials and Methods A retrospective review was performed to identify patients 80 years or older who were treated for a distal radius fracture with open reduction and internal fixation (ORIF). Medical records were reviewed for demographics, medical history, functional outcomes including quick Disabilities of the Arm, Shoulder, and Hand (qDASH), radiographs, and postoperative complications.

Results There were 40 patients included for review. Average age was 84 years. The preoperative qDASH score was 69. At 6 months follow-up, the postoperative qDASH score was 13 (p < 0.001). There were five (12.5%) complications reported postoperatively. All fractures healed with adequate radiographic alignment and there were no hardware failures.

Conclusion Distal radius fractures in patients older than 80 years treated with ORIF have good functional outcomes and low complication rates. Increased functionality and independence of the elderly, as well as updated implant design can lead to the effective surgical management of these patients. When indicated from a clinical perspective, operative fixation of distal radius fractures should be considered in patients older than 80 years.



Publication History

Article published online:
23 September 2021

© 2021. Society of Indian Hand Surgery & Microsurgeons. All rights reserved.

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

 
  • References

  • 1 Court-Brown CM, McQueen MM. Global forum: fractures in the elderly. J Bone Joint Surg Am 2016; 98 (09) e36
  • 2 Schoeni RF, Freedman VA, Wallace RB. Persistent, consistent, widespread, and robust? Another look at recent trends in old-age disability. J Gerontol B Psychol Sci Soc Sci 2001; 56 (04) S206-S218
  • 3 Orbay JL, Fernandez DL. Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient. J Hand Surg Am 2004; 29 (01) 96-102
  • 4 Rundgren J, Bojan A, Mellstrand Navarro C, Enocson A. Epidemiology, classification, treatment and mortality of distal radius fractures in adults: an observational study of 23,394 fractures from the national Swedish fracture register. BMC Musculoskelet Disord 2020; 21 (01) 88
  • 5 Chung KC, Shauver MJ, Birkmeyer JD. Trends in the United States in the treatment of distal radial fractures in the elderly. J Bone Joint Surg Am 2009; 91 (08) 1868-1873
  • 6 Saving J, Severin Wahlgren S, Olsson K. et al. Nonoperative treatment compared with volar locking plate fixation for dorsally displaced distal radial fractures in the elderly: a randomized controlled trial. J Bone Joint Surg Am 2019; 101 (11) 961-969
  • 7 Martinez-Mendez D, Lizaur-Utrilla A, de-Juan-Herrero J. Intra-articular distal radius fractures in elderly patients: a randomized prospective study of casting versus volar plating. J Hand Surg Eur Vol 2018; 43 (02) 142-147
  • 8 Blakeney WG. Stabilization and treatment of Colles' fractures in elderly patients. Clin Interv Aging 2010; 5: 337-344
  • 9 Jupiter JB, Ring D, Weitzel PP. Surgical treatment of redisplaced fractures of the distal radius in patients older than 60 years. J Hand Surg Am 2002; 27 (04) 714-723
  • 10 Chung KC, Squitieri L, Kim HM. Comparative outcomes study using the volar locking plating system for distal radius fractures in both young adults and adults older than 60 years. J Hand Surg Am 2008; 33 (06) 809-819
  • 11 Beharrie AW, Beredjiklian PK, Bozentka DJ. Functional outcomes after open reduction and internal fixation for treatment of displaced distal radius fractures in patients over 60 years of age. J Orthop Trauma 2004; 18 (10) 680-686
  • 12 Court-Brown CM, Clement N. Four score years and ten: an analysis of the epidemiology of fractures in the very elderly. Injury 2009; 40 (10) 1111-1114
  • 13 Clement ND, Duckworth AD, Court-Brown CM, McQueen MM. Distal radial fractures in the superelderly: does malunion affect functional outcome?. ISRN Orthop 2014; 2014: 189803
  • 14 Heng BQH, Kang YC, Lim JXY, Chee KG. Epidemiology of distal radius fixations and functional outcomes in the superelderly population. J Hand Surg Asian Pac Vol 2020; 25 (01) 26-31
  • 15 Tulipan JE, Lechtig A, Rozental TD, Harper CM. “Age is just a number”: distal radius fractures in patients over 75. Hand (N Y) 2020; 1558944720906552
  • 16 Arora R, Lutz M, Deml C, Krappinger D, Haug L, Gabl M. A prospective randomized trial comparing nonoperative treatment with volar locking plate fixation for displaced and unstable distal radial fractures in patients sixty-five years of age and older. J Bone Joint Surg Am 2011; 93 (23) 2146-2153
  • 17 Bartl C, Stengel D, Bruckner T, Gebhard F. The treatment of displaced intra-articular distal radius fractures in elderly patients. Dtsch Arztebl Int 2014; 111: 779-787
  • 18 Egol KA, Walsh M, Romo-Cardoso S, Dorsky S, Paksima N. Distal radial fractures in the elderly: operative compared with nonoperative treatment. J Bone Joint Surg Am 2010; 92 (09) 1851-1857
  • 19 Aasheim T, Finsen V. The DASH and the QuickDASH instruments. Normative values in the general population in Norway. J Hand Surg Eur Vol 2014; 39 (02) 140-144
  • 20 Arora R, Gabl M, Gschwentner M, Deml C, Krappinger D, Lutz M. A comparative study of clinical and radiologic outcomes of unstable Colles type distal radius fractures in patients older than 70 years: nonoperative treatment versus volar locking plating. J Orthop Trauma 2009; 23 (04) 237-242