Background The deep inferior epigastric perforator (DIEP) flap is the most common perforator
flap for microsurgical breast reconstruction. Contrary to the conventional open approach,
robotic-assisted DIEP flap harvest intends to preserve ARS integrity, thereby reducing
the morbidity. We assessed the feasibility and compared performance outcomes of a
robotic, cadaveric training model for DIEP flap harvest using two approaches: transabdominal
preperitoneal (TAPP) and totally extraperitoneal (TEP).
Methods A robotics system (da Vinci Xi) was applied in conjunction with a cadaveric training
model. Ports were placed in the abdominal wall to triangulate each DIEP flap. Surgical
time and technical characteristics were recorded. Values were analyzed and compared.
Results Eight female cadavers (16 hemi-DIEP flaps) were dissected: 50% TAPP and 50% TEP approaches.
Mean harvest time was 56 minutes (range: 48–74 minutes) and 65 minutes (range: 60–83 minutes)
for TAPP versus TEP groups, respectively (p < 0.05). Mean pedicle dissection time was 36 minutes (range: 25–40 minutes) and 39 minutes
(range: 30–42 minutes) for TAPP versus TEP groups, respectively (p > 0.05). Intra-abdominal contents were manipulated twice on average in the TAPP group
versus 0 times in the TEP group (p < 0.05). One TAPP case had an injury to the bowel, and one TEP case was converted
to conventional open due to pneumoperitoneum.
Conclusion Robotic-assisted DIEP flap harvest represents a technological enhancement for advanced
regenerative plastic surgery. Our model demonstrated both TAPP and TEP are feasible,
with TEP less invasive, preserving the posterior rectus sheath, and decreasing complication
risks. However, there is a steeper and longer learning curve for TEP.