Vet Comp Orthop Traumatol 1996; 09(01): 14-21
DOI: 10.1055/s-0038-1632496
Original Research
Schattauer GmbH

Mechanical Evaluation of Soft Cast (Scotchcast, 3M) and Conventional Rigid and Semi-rigid Coaptation Methods

U. Rytz
1   From the 1Department of Small Animal Medicine, College of Veterinary Medicine, Athens, Georgia, USA
,
D. N. Aron
1   From the 1Department of Small Animal Medicine, College of Veterinary Medicine, Athens, Georgia, USA
,
T. L. Foutz
2   Department of Agricultural Engineering, College of Agriculture, University of Georgia, Athens, Georgia, USA
,
S. A. Thompson
2   Department of Agricultural Engineering, College of Agriculture, University of Georgia, Athens, Georgia, USA
› Author Affiliations
Further Information

Publication History

Received for publication 09 January 1995

Publication Date:
10 February 2018 (online)

Summary

A clinically relevant model was created to mechanically evaluate different rigid and semi-rigid coaptation methods. Modulus of elasticity, yield stress, resilience and stiffness was measured to describe material strength and structure stiffness. Rigid Vetcast Plus, 3 M (VCP), new semi-rigid Softcast Scotchcast, 3 M (SC), conventional semi-rigid fibreglass slab reinforced modified Rober t Jone s (SMRJ ) bandages, and modified Robert Jones (MRJ ) bandages were tested with different thicknesses or configurations. Rigid (VCP) was the strongest and stiffest coaptation method. The reason for this was a strong bond between fibres and resin and between layers. New semi-rigid (SC) was the strongest of the semi-rigid coaptation methods followed by (SMRJ ) bandages and (MRJ ) bandages. With semi-rigid (SC) imperfections and voids in bond allowed some shear movement between fibres and resin and between layers giving cylindrical structures some resilience. Stiffness of semi-rigid (SMRJ ) was influenced by the position of the slab relative to the bending plane. Compressed cotton with semi-rigid (MRJ ) had very limited resistance to a bending force.

New semi-rigid Softcast Scotch-cat, 3M (SC) was mechanically evaluated in an in vitro external coaptation model and compared to rigid Vetcast Plus, 3M (VCP), semi-rigid fibreglass slab reinforced modified Robert Jones (SMRJ) bandages, and modified Robert Jones (MRJ) bandages. Vetcast Plus (VCP) was overall the strongest, Scotchcast (SC) was the strongest of the semi-rigid coaptation methods.

 
  • REFERENCES

  • 1 Fox SM. External coaptation bandages: How and when to use them. Vet Med 1988; 2: 153-64.
  • 2 Leighton R. Principals of conservative fracture management: Splints and casts. Sem Vet Med Surg (Small Anim) 1991; 6: 39-51.
  • 3 Knecht C. Principles and application of traction and coaptation splints. Vet Clin North Am Small Anim Pract 1975; 5: 177-95.
  • 4 Tomlinson J. Complications of fractures repaired with casts and splints. Vet Clin North Am Small Anim Pract 1991; 21: 735-45.
  • 5 Hohn RB. Principles and application of plaster casts. Vet Clin North Am Small Anim Pract 1975; 5: 291-303.
  • 6 Knecht CD. Principals of temporary splints. Vet Clin North Am Small Anim Pract 1975; 5: 165-75.
  • 7 Silverskiold JP. Fiberglass versus plaster casts. Postgrad Med 1989; 86: 71-4.
  • 8 Davie B, Dooley B. New fiberglass casting system in orthopaedic practice. Med J Aust 1976; 1: 1010-2.
  • 9 DeCamp CE. External coaptation. In: Textbook of Small Animal Surgery. Slatter D. (ed) Philadelphia: Saunders; 1993: 1661-76.
  • 10 Nunamaker DM. Methods of closed fixation. In: Textbook of Small Animal Orthopaedics. Newton CD, Nunamaker DM. (eds) Philadelphia: Lippincott; 1985: 249-59.
  • 11 Bartels KE. Synthetic and plaster casts. In: Current techniques in Small Animal Surgery. Bojrab MJ. (ed) Philadelphia: Lea & Febiger; 1990: 1913-8.
  • 12 Bartels KE. Splinting techniques for small animals. In: Current Techniques in Small Animal Surgery. Bojrab MJ. (ed) Philadelphia: Lea & Febiger; 1990: 1921-9.
  • 13 Bartels KE, Penwick RC, Freeman LJ. et al Mechanical testing and evaluation of eight synthetic casting materials. Vet Surg 1985; 14: 310-8.
  • 14 Morier RL, Weiss PL, Kearney RE. Low inertia, rigid limb fixation using flass fibre casting bandage. Med Biol Eng Comput 1990; 28: 96-9.
  • 15 Ehrenzweig J, Diefenbach J, Campanile P. A lightweight orthopedic casting system. Can Pract 1976; 6: 31-41.
  • 16 Houlton JEF. A new polymer splinting material. Vet Rec 1981; 109: 10-2.
  • 17 Knapp DW. Robert-Jones bandage. In: Current Techniques in Small Animal Surgery. Bojrab MJ. (Ed) Philadelphia: Lea & Febiger; 1990: 1918-9.
  • 18 Behrens F, Kraft EL, Oegman TR. Biochemical changes in articular cartilage after joint immobilization by casting or external fixation. J Orthop Res 1989; 7: 335-43.
  • 19 Akeson WH. Effect of immobilization on joints. Clin Orthop 1987; 219: 28-37.
  • 20 Richardson DW, Clark CC. Effects of short-term cast immobilization on equine articular cartilage. Am J Vet Res 1993; 54: 449-53.
  • 21 Akeson WH, Woo SY, Amile D. et al The connective tissue response to immobility: biochemical changes in periarticular connective tissue of the immobilized rabbit knee. Clin Orthop 1973; 93: 356-62.
  • 22 Akeson WH, Amile D, Abel MF. et al Effects of immobilization on joints. Clin Orthop 1987; 219: 28-37.
  • 23 Piper TL, Whiteside LA. Early immobilization after knee ligament repair in dogs. Clin Orthop 1980; 150: 277-82.
  • 24 Ogata K, Whiteside LA, Andersen DA. The intra-articular effect of various postoperative managements following knee ligament repair. Clin Orthop 1980; 150: 271-6.
  • 25 Scotchcast Soft Cast: Instructions for use. 3M Animal Care Products, St. Paul, MN. 1992
  • 26 Schenck T, Somerset JH. Stresses in Orthopedic walking casts. J Biomech 1969; 2: 227-39.
  • 27 Houlton JEF, Brearley MJ. A comparison of some casting materials. Vet Rec 1985; 117: 55-8.
  • 28 Dingwall JS, Horney FD, McDonel l. et al A comparison of breaking strength of various casting materials. Can Vet J 1973; 14: 62-5.
  • 29 Vetcast Plus Veterinary Casting Tape: Instructions for use. 3M Animal Care Products, St. Paul, MN. 1987
  • 30 Nordin M, Frankel VH. (ed) Basic Biomechanics of the Musculosceletal System. Philadelphia: Lea & Febiger; 1989
  • 31 Agarwall BD, Broutman LJ. Analysis and Performance of Fiber Composites. New YorkM: Wiley-Interscience; 1980
  • 32 Mueller ME, Allgoewer M, Schneider R. et al Manual of Internal Fixation. Berlin: Springer; 1991