Nuklearmedizin 1979; 18(04): 167-171
DOI: 10.1055/s-0037-1620894
Originalarbeiten - Original Articles
Schattauer GmbH

Zur Anwendung der harmonischen Analyse bei der Funktionsszintigraphie des Herzens[*]

Application of Harmonie Analysis in Quantitative Heart Scintigraphy
P. Fischer
1   Aus derh Institut für klinische und experimentelle Nuklearmedizin (Direktor: Prof. Dr. Dr. h. c. C. Winkler) der Universität Bonn, Bundesrepublik Deutschland
,
R. Knopp
1   Aus derh Institut für klinische und experimentelle Nuklearmedizin (Direktor: Prof. Dr. Dr. h. c. C. Winkler) der Universität Bonn, Bundesrepublik Deutschland
,
H.-P. Breuel
1   Aus derh Institut für klinische und experimentelle Nuklearmedizin (Direktor: Prof. Dr. Dr. h. c. C. Winkler) der Universität Bonn, Bundesrepublik Deutschland
› Author Affiliations
Further Information

Publication History

Publication Date:
03 February 2018 (online)

Zusammenfassung

Die nach Gleichverteilung von 99mTc-Serumalbumin szintigraphisch gewonnenen Volumenkurven des linken Ventrikels werden zur Gewinnung aussagefähiger Ergebnisse einer harmonischen Analyse unterzogen. Es ergibt sich hierdurch die Möglichkeit der quantitativen Analyse der Volumenkurve in geschlossener Form. Die Resynthese nach Fourier-Transformation stellt für den vorliegenden Funktionstyp ein gut geeignetes Glättungsverfahren dar, so daß die aus den Volumenkurven berechneten Parameter Ejektionsfraktion, maximale Austreibungs- und Füllungsgeschwindigkeit mit großer Genauigkeit erfaßt werden.

Summary

Quantitative scintigraphy of the heart after equilibrium distribution of a radioactive tracer permits the measurement of time activity curves in the left ventricle during a representative heart cycle with great statistical accuracy. In the range of ventricular volumes which usually occur, the time activity curve corresponds with sufficient accuracy to the ventricular volume variation during one heart cycle. In cardiological terms, the parameters ejection fraction as well as maximum rates of ejection and filling have proved useful for evaluation of hemodynamic performance. By application of Fourier's analysis, criteria are to be attained in addition for evaluation of the volume curve as a whole. Thus the entire information contained in the volume curve is completely described in a Fourier spectrum.

Because of the statistical noise, the volume curves drawn up from scintigraphic techniques require smoothing procedures, especially in determination of the differential quotients of ejection and filling rate. Smoothing by means of sliding average procedures causes a systematic deformation of the systolic dip and other similar regions of the curve, since the curve smoothened in this way does not converge towards the original curve at these points. Resynthesis after Fourier transformation seems to be an ideal method of smoothing because of its convergence in the minimum quadratic error for the type of function concerned.

* Herrn Prof. Dr. Dr. h. c. C. Winkler zum 60. Geburtstag gewidmet.


 
  • Literatur

  • (1) Breuel H-P, Knopp R, Felix R, Neumann K, Altland H, Winkler C. Funktionsszintigraphie der Kontraktion des linken Ventrikels. II. Methodische Untersuchungen zur Background-Korrektur. Fortschr. Roentgenstr 129: 18-23 1978;
  • (2) Breuel H-P, Simon H, Bahre M, Otten H, Knopp R, Fischer P, Winkler C. Die Funktionsszintigraphie des Herzens nach Indikatorgleichverteilung zur nichtinvasiven Beurteilung der links-ventrikulären Funktion. Klin. Wochenschr 57: 839-844 1979;
  • (3) Hammeremeister K E, Brooks RC, Warbasse IR. The rate of change of left ventricular volume in man. I. Validation and peak systolic ejection rate in health and disease. Circulation 49: 729-738 1974;
  • (4) Knopp R, Breuel H-P, Schmidt H, Winkler C. Funktionsszintigraphie des Herzens. I. Datentechnische Grundlagen und Methodik. Fortschr. Roentgenstr 128: 44-47 1978;
  • (5) Spiller P. Quantitative Laevokardiographie. Urban und Schwarzenberg, München, 1978.