Endoscopy 2020; 52(09): 773-779
DOI: 10.1055/a-1145-3412
Original article

Efficacy of a novel self-assembling peptide hemostatic gel as rescue therapy for refractory acute gastrointestinal bleeding

Germana de Nucci
1   Gastroenterology and Endoscopy Unit, Aziende Socio Sanitaria Territoriale Rhodense – Garbagnate Milanese, Milan, Italy
,
Raffaella Reati
1   Gastroenterology and Endoscopy Unit, Aziende Socio Sanitaria Territoriale Rhodense – Garbagnate Milanese, Milan, Italy
,
Ilaria Arena
2   Gastroenterology and Endoscopy Unit, Aziende Socio Sanitaria Territoriale Rhodense – Rho Hospital, Milan, Italy
,
Cristina Bezzio
2   Gastroenterology and Endoscopy Unit, Aziende Socio Sanitaria Territoriale Rhodense – Rho Hospital, Milan, Italy
,
Massimo Devani
2   Gastroenterology and Endoscopy Unit, Aziende Socio Sanitaria Territoriale Rhodense – Rho Hospital, Milan, Italy
,
Cristina della Corte
2   Gastroenterology and Endoscopy Unit, Aziende Socio Sanitaria Territoriale Rhodense – Rho Hospital, Milan, Italy
,
Daniela Morganti
1   Gastroenterology and Endoscopy Unit, Aziende Socio Sanitaria Territoriale Rhodense – Garbagnate Milanese, Milan, Italy
,
Enzo Domenico Mandelli
1   Gastroenterology and Endoscopy Unit, Aziende Socio Sanitaria Territoriale Rhodense – Garbagnate Milanese, Milan, Italy
,
Barbara Omazzi
2   Gastroenterology and Endoscopy Unit, Aziende Socio Sanitaria Territoriale Rhodense – Rho Hospital, Milan, Italy
,
Davide Redaelli
1   Gastroenterology and Endoscopy Unit, Aziende Socio Sanitaria Territoriale Rhodense – Garbagnate Milanese, Milan, Italy
,
Simone Saibeni
2   Gastroenterology and Endoscopy Unit, Aziende Socio Sanitaria Territoriale Rhodense – Rho Hospital, Milan, Italy
,
Marco Dinelli
3   Endoscopy Unit, San Gerardo Hospital, Monza, Italy
,
Gianpiero Manes
1   Gastroenterology and Endoscopy Unit, Aziende Socio Sanitaria Territoriale Rhodense – Garbagnate Milanese, Milan, Italy
2   Gastroenterology and Endoscopy Unit, Aziende Socio Sanitaria Territoriale Rhodense – Rho Hospital, Milan, Italy
› Author Affiliations

Abstract

Background Acute gastrointestinal bleeding (AGIB) results in significant morbidity and mortality. Topical hemostatic products have been developed for endoscopic use to help in the management of difficult bleeding. Our aim was to demonstrate the ease of use, safety, and efficacy of PuraStat, a novel hemostat, to control AGIB.

Methods We describe 77 patients (41 men) who were treated for acute upper and lower AGIB in a 2-year period. In 50 patients, bleeding occurred as a complication of a previous endoscopic procedure, predominantly endoscopic mucosal resection (EMR) and endoscopic retrograde cholangiopancreatography (ERCP); however, in the other 27 patients, it derived from peptic ulcers, angiodysplasia, cancers, and surgical anastomoses. Bleeding was spurting in 13 of the 77 patients and oozing in 64. PuraStat was used after the failure of at least two conventional hemostatic methods.

Results A mean of 2.6 conventional hemostatic methods had been attempted prior to the application of PuraStat. PuraStat achieved successful hemostasis in 90.9 % of patients. In 41 patients, once hemostasis was obtained with PuraStat, endoscopists further stabilized hemostasis by using at least one additional method. Recurrence of bleeding was observed in eight patients (10.4 %). In 16 patients with intraprocedural bleeding, it was possible to complete the procedures (14 EMR, 2 ERCP) after PuraStat hemostasis. No adverse events related to PuraStat were recorded.

Conclusions PuraStat is feasible, safe, and effective in controlling different types of gastrointestinal hemorrhage after failure of conventional hemostatic methods. Its application also does not hinder continuing endotherapy.



Publication History

Received: 23 December 2019

Accepted: 10 March 2020

Article published online:
21 April 2020

© Georg Thieme Verlag KG
Stuttgart · New York

 
  • References

  • 1 Gralnek IM, Dumonceau JM, Kuipers EJ. et al. Diagnosis and management of nonvariceal upper gastrointestinal hemorrhage: European Society of Gastrointestinal Endoscopy (ESGE) Guideline. Endoscopy 2015; 47: a1-a46
  • 2 Cook DJ, Guyatt GH, Salena BJ. et al. Endoscopic therapy for acute nonvariceal upper gastrointestinal hemorrhage: a meta-analysis. Gastroenterology 1992; 102: 139-148
  • 3 Mourad FH, Leong RW. Role of hemostatic powders in the management of lower gastrointestinal bleeding: A review. J Gastroenterol Hepatol 2018; 33: 1445-1453
  • 4 Sung JJ, Luo D, Wu JC. et al. Early clinical experience of the safety and effectiveness of Hemospray in achieving hemostasis in patients with acute peptic ulcer bleeding. Endoscopy 2011; 43: 291-295
  • 5 Huang R, Pan Y, Hui N. et al. Polysaccharide hemostatic system for hemostasis management in colorectal endoscopic mucosal resection. Dig Endosc 2014; 26: 63-68
  • 6 Karaman A, Baskol M, Gursoy S. et al. Endoscopic topical application of Ankaferd Blood Stopper in gastrointestinal bleeding. J Altern Complement Med 2012; 18: 65-68
  • 7 Cahyadi O, Bauder M, Meier B. et al. Effectiveness of TC-325 (Hemospray) for treatment of diffuse or refractory upper gastrointestinal bleeding – a single centre experience. Endosc Int Open 2017; 5: E1159-E1164
  • 8 Chen YI, Barkun A, Nolan S. Hemostatic powder TC-325 in the management of upper and lower gastrointestinal bleeding: a two-year experience at a single institution. Endoscopy 2015; 47: 167-171
  • 9 Prei JC, Barmeyer C, Burgel N. et al. EndoClot polysaccharide hemostatic system in nonvariceal gastrointestinal bleeding: Results of a prospective multicenter observational pilot study. J Clin Gastroenterol 2016; 50: e95-e100
  • 10 Matsumura K, Nakajima N, Sugai H. et al. Self-degradation of tissue adhesive based on oxidized dextran and poly-L-lysine. Carbohydr Polym 2014; 113: 32-38
  • 11 Luo Z, Wang S, Zhang S. Fabrication of self-assembling d-form peptide nanofiber scaffold d-EAK16 for rapid hemostasis. Biomaterials 2011; 32: 2013-2020
  • 12 Song H, Zhang L, Zhao X. Hemostatic efficacy of biological self-assembling peptide nanofibers in a rat kidney model. Macromol Biosci 2010; 10: 33-39
  • 13 Masuhara H, Fujii T, Watanabe Y. et al. Novel infectious agent-free hemostatic material (TDM-621) in cardiovascular surgery. Ann Thorac Cardiovasc Surg Methods Enzymol 2012; 18: 444-451
  • 14 Subramaniam S, Kandiah K, Thayalasekaran S. et al. Haemostasis and prevention of bleeding related to ER: The role of a novel self-assembling peptide. United European Gastroenterol J 2019; 7: 155-162
  • 15 Yoshida M, Goto N, Kawaguchi M. et al. Initial clinical trial of a novel hemostat, TDM-621, in the endoscopic treatments of the gastric tumors. J Gastroenterol Hepatol 2014; 29 (Suppl. 04) 77-79
  • 16 Uraoka T, Ochiai Y, Fujimoto A. et al. A novel fully synthetic and self-assembled peptide solution for endoscopic submucosal dissection-induced ulcer in the stomach. Gastrointest Endosc 2016; 83: 1259-1264
  • 17 Pioche M, Camus M, Rivory J. et al. A self-assembling matrix-forming gel can be easily and safely applied to prevent delayed bleeding after ERs. Endosc Int Open 2016; 4: E415-E419
  • 18 Yau AH, Ou G, Galorport C. et al. Safety and efficacy of Hemospray(R) in upper gastrointestinal bleeding. Can J Gastroenterol Hepatol 2014; 28: 72-76
  • 19 Chen YI, Barkun A, Nolan S. Hemostatic powder TC-325 in the management of upper and lower gastrointestinal bleeding: a two-year experience at a single institution. Endoscopy 2015; 47: 167-171
  • 20 Sulz MC, Frei R, Meyenberger C. et al. Routine use of Hemospray for gastrointestinal bleeding: prospective two-center experience in Switzerland. Endoscopy 2014; 46: 619-624
  • 21 Smith LA, Stanley AJ, Bergman JJ. et al. Hemospray application in nonvariceal upper gastrointestinal bleeding: results of the Survey to Evaluate the Application of Hemospray in the Luminal Tract. J Clin Gastroenterol 2014; 48: e89-e92
  • 22 Haddara S, Jacques J, Lecleire S. et al. A novel hemostatic powder for upper gastrointestinal bleeding: a multicenter study (the "GRAPHE" registry). Endoscopy 2016; 48: 1084-1095