Influence of light activation of simplified adhesives on the shear bond strength of resin cements to a leucite-reinforced ceramic

Adilson Yoshio Furuse
1   Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of Sao Paulo, Sao Paulo, Brazil
,
Cassiana Koch Scotti
1   Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of Sao Paulo, Sao Paulo, Brazil
,
Alfredo Llerena-Icochea
1   Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of Sao Paulo, Sao Paulo, Brazil
,
Juliana Fraga Soares Bombonatti
1   Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of Sao Paulo, Sao Paulo, Brazil
,
Gisele Aihara Haragushiku
2   Graduate Program in Dentistry, Positivo University, Curitiba, Brazil
,
Carla Castiglia Gonzaga
2   Graduate Program in Dentistry, Positivo University, Curitiba, Brazil
› Institutsangaben
Weitere Informationen

Correspondence:

Dr. Juliana Fraga Soares Bombonatti

Publikationsverlauf

Publikationsdatum:
13. September 2019 (online)

 

ABSTRACT

Objective This study aims to evaluate the influence of the light activation of simplified adhesives on the shear bond strength of resin cements to a glass-ceramic. Three factors were evaluated: (1) cement in two levels (light cured and dual cured); (2) adhesive in two levels (Single Bond 2 and Single Bond Universal), and (3) light activation in two levels (yes or no). Materials and Methods Thirty-two 1-mm thick slices of a leucite-reinforced glass-ceramic (IPS Empress CAD) were divided into eight groups according to adhesive (Single Bond 2 or Single Bond Universal), cement (AllCem Veneer or AllCem), and light activation of the adhesive before application of the cement (yes or no). Ceramic surfaces were etched for 60 s with 5% hydrofluoric acid, and adhesives were applied. Four cement cylinders were made over each ceramic slice (n = 16) and then submitted to shear bond strength tests. Statistical Analysis Data were analyzed with three-way ANOVA and Tukey (⍺ = 0.05). Results: There were significant differences between adhesives (P < 0.0001) and no differences between cements (P = 0.0763) and light activation (P = 0.4385). No interaction effect occurred (P = 0.05). Single Bond 2 showed higher bond strength than Single Bond Universal. Conclusions: The light activation of the adhesive before the application of the resin cement did not influence the bond strength.


Introduction

Dental ceramics are among the main materials due to their well-recognized esthetic properties, precision, biocompatibility, and strength.[1]-[3] Despite physical and mechanical properties, the marginal adaption after cementing is still a concern. Acid-sensitive ceramics, such as glass-ceramics, require etching with hydrofluoric acid and a silane-coupling agent, followed by an adhesive for bonding between the resin cement and the ceramics.[4]-[6] Although the light activation of the adhesive before cementation is recommended,[7],[8] the fit of the restoration may be impaired if there is adhesive excess. To avoid this problem, an alternative is applying the adhesive without light activating it before applying the resin cement. However, the influence of this nonlight-activation technique on the bond strength of resin-based cements to ceramics still needs evaluation as the compatibility between cements and adhesives is important. The nonlight activation could generate unwanted chemical reactions, depending on type of cement, pH, and hydrophilicity of adhesives.[9]-[13]

Among adhesive systems, universal (multimode or multipurpose) share a wide versatility and high performance due to their composition. The addition of silane-coupling agents could promote adhesion between intrinsically different materials such as resin cements and ceramics. However, the pH of universal adhesives (around 2.7-3.0) could lead to lower compatibility with dual-cured cements when used without activators such as arylsulfinate salts.

Considering differences between dual-cured and light-cured resin cements and the potential incompatibility between simplified adhesives and dual-cured cements when adhesives are not light activated before cementation, this study evaluated the influence of light-activating simplified adhesives on the shear bond strength of resin cements to a leucite-reinforced glass-ceramic. Null hypotheses were that there would be no differences between shear bond strengths of (i) two simplified adhesives; (ii) two resin cements; and (iii) two adhesive light-activation protocols.


Materials and Methods

Thirty-two 1-mm thick slices obtained from leucite-reinforced ceramic blocks (IPS Empress CAD, Ivoclar Vivadent, Liechtenstein) were embedded in 3/4” Polyvinyl chloride tubes with self-curing acrylic resin and then polished (Ecomet Buehler, Lake Bluff/IL, USA) with sandpapers (granulometry #400 to #600) under water cooling.

Slices were etched for 60 s with 5% hydrofluoric acid (Condac Porcelana, FGM, Joinville/SC, Brazil) and divided into eight groups according to the adhesive (two-step etch-and-rinse [Single Bond 2, 3M ESPE, St. Paul/MN, EUA] or one-bottle universal adhesive [Single Bond Universal, 3M ESPE]), resin cement (dual cured [AllCem, FGM] and light cured [AllCem Veneer, FGM]) and light activation of the adhesive (light activation or nonlight activation). Light activation was performed with a light-emitting diode (LED) device (Valo Cordless, Ultradent, South Jordan/UT, USA) with irradiance of 1000 mW/cm2 for the manufacturer’s recommended time.

For Single Bond 2 groups, a silane-coupling agent (Prosil, FGM) was applied for 1 min, followed by 5-s air drying, before adhesive application. Single Bond Universal was used without silane-coupling agent as follows: application and waiting for 10 s, 10-s solvent evaporation, and 10-s light activation (depending on the group). Materials are described in [Tables 1].

Table 1:

Materials used in this study

Material

Brand

Composition

BisGMA: Bisphenol A diglycidyl ether dimethacrylate,

TEGDMA: Triethylene glycol dimethacrylate, BisBMA: Bisphenol

A glycol dimethacrylate, HEMA: Hydroxyethyl methacrylate

Universal adhesive

Scotchbond Universal (3M ESPE)

Hydroxyethyl methacrylate, BisGMA, decamethylene dimethacrylate, ethanol, silane-treated silica, water, 2-propenoic acid, 2-methyl, 10-decanediol, phosphorous oxide, copolymer of acrylic and itaconic acid, dimethylaminoethyl methacrylate, camphorquinone, dimethylaminobenzoate, 2-6-di-tert-butyl-p-cresol

Self-etching adhesive

Adper Single Bond 2 (3M ESPE)

Methacrylic monomers (BisGMA/HEMA), dimethacrylates, ethanol, water, methacrylate functional copolymer of polyacrylic, polyitaconic acid

Dual-cured resin cement

AllCem (FGM)

Base paste: Methacrylic monomers (TEGDMA/BisEMA/BisGMA), camphorquinone, coinitiators, barium, aluminum-silicate glass microparticles, silicone dioxide nanoparticles, inorganic pigments Catalyst: Methacrylic monomers, dibenzoil, peroxide and stabilizers, aluminum silicate glass microparticles

Light-activated resin cement

AllCem Methacrylic monomers

Veneer (FGM) camphorquinone, coinitiators, pigments, barium-aluminum-silicate silanized glass particles and silicone dioxide

Resin cement cylinders were fabricated with surgical catheters (inner diameter of 1.40 mm and height of 1 mm). Four cylinders per ceramic substrate were made (16 cylinders per group). Resin cements were inserted in the catheters and light activated for 20 s with the same LED device. After 10-min waiting, catheters were removed with #12 scalpel blades to expose cement cylinders. Samples were stored in 37°C deionized water for 24 h and then submitted to the shear bond strength evaluation (Instron, High Wycombe, United Kingdom) using a 0.2-mm wire loop and 0.5 mm/min crosshead speed. A stereomicroscope was used to evaluate the type of failure: adhesive, cohesive in cement, cohesive in ceramic, and mixed. Data were analyzed with three-way ANOVA and Tukey (α = 5%).


Results

[Tables 2] shows means and standard deviations. There were significant differences between adhesives (P < 0.0001). Higher overall shear bond strength values were observed with Single Bond Universal. There were no differences between resin cements (P = 0.0763) and light-activation protocols (P = 0.4385). Double and triple interactions were not significant (P > 0.05).

Table 2:

Shear bond strength means and standard deviations

Adhesive

Cement

Light-activation protocol for the adhesive layer

Shear bond strength (MPa)

Single Bond Universal

AllCem

Yes

18.53 (4.6)

Veneer

No

18.47 (5.6)

AllCem

Yes

19.06 (11.3)

No

22.06 (5.2)

Single Bond 2

AllCem

Yes

13.47 (3.9)

Veneer

No

14.01 (5.4)

AllCem

Yes

15.76 (5.34)

No

15.48 (4.17)


Discussion

The influence of scanning accuracy of computer-aided design-computer-aided manufacturing systems, dental preparation, and polishing step on marginal and internal adaptation of ceramic systems have been investigated.[14]-[17] However, the nonlight activation of adhesives during the cementation is an important factor that is closely related to clinical procedures and certainly is a reason of concern among clinicians, especially when universal adhesives are employed. The nonlight activation of adhesives not only would allow reducing operative steps and easing the adaption of prosthetic restorations but also could simplify the cementation by reducing technique sensitivity. For this reason, the present study was designed to address the bond strength using two different categories of simplified adhesives, including a universal one, with light-cured and dual-cured resin cements. According to the results, the only null hypothesis accepted was that there would be no differences between adhesives. Thus, the chemical incompatibility between the evaluated simplified adhesives and the dual-cured resin cement was not significant, which differs from the idea that simplified adhesives are incompatible to dual-cured resin cements.[18],[19]

The present study shows that there was no direct relationship between shear bond strength and resin cements (i.e., light cured and dual cured). The absence of difference between cements could be explained by the fact that the light activation was performed directly over the cement. Thus, it is assumed that most of the reaction happened at the expense of the light activation for both cements because all specimens were light activated immediately rather than waiting for chemical polymerization. It is noteworthy that delaying light activation could impact properties of dual-cured resin cements.[20] Furthermore, in a clinical situation, the ceramics thickness may play a major role on the light activation. Depending on the type, thickness, and color of the ceramic, the radiant exposure may not be enough due to attenuation, compromising the polymerization process.[21]-[24]

In the present study, factors such as thickness and composition of ceramic, light transmittance through the ceramic material, characteristics of the lightcuring device, radiant exposure, and concentration of hydrofluoridric acid were not evaluated. For this reason, results of this study could be different not only if the ceramics were interposed but also if many other factors were changed.

Regarding the bonding agents, results obtained are in accordance with other studies.[25]-[27] The present study found higher overall shear bond strength for the universal adhesive. This may be explained by the idea that universal adhesives do not share the particularities of other simplified etch-and-rinse systems.[26],[28] In the case of simplified self-etching adhesives, due to the poorly polymerized oxygen-inhibited layer, the residual acidic resin monomers may react with basic catalytic components such as tertiary amines by bimolecular redox reaction which involves an electron transfer that prevents the generation of free radicals and compromises the chemical reaction.[19]

The presence of 10-methacryloyloxydecyl dihydrogen phosphate monomer in Single Bond Universal could explain the best results due to the fact that hydroxyl groups may chemically react with the resin cement and the glass-ceramic phase. Moreover, the incorporation of a silane-coupling agent in this material could improve the interaction with silica through covalent bonds, avoiding the formation of contaminating layers that could weaken bond strength.[29]

The shear bond strength method was used instead of a tensile one since it may predict lateral forces and avoid pretesting failures since it is less technique sensitive during specimen preparation. The use of wire loop may lead to a better stress distribution at the bonding area, unlike the severe stress concentration at the load application area by knife-edge chisels.[30] In addition, the small bonding area of cement cylinders decreases the likelihood of a critical flaw being present. Regarding the bond durability and aging degradation, no artificial aging process was performed. For this reason, the results of the present study could be different if long-term water storage, thermocycling, or fatigue methods were employed. Thus, further studies testing long-term durability of these combinations of adhesives and dual-activated cements with nonlight-activated protocol are still needed.


Conclusion

According to the results of this study, the non-light- activation protocol of simplified adhesives did not influence the shear bond strength of resin cements to a leucite-reinforced glass-ceramic. The universal adhesive presented better performance on bond strength values when compared to the etch-and-rinse simplified adhesive.

Financial support and sponsorship

Nil.




Conflicts of interest

There are no conflicts of interest.

Acknowledgments

The present study was partially supported by he Brazilian National Council for Scientific and Technological Development (grant CNPq 14034/2016-9).


Correspondence:

Dr. Juliana Fraga Soares Bombonatti