Open Access
CC BY-NC-ND 4.0 · Indian J Plast Surg 2014; 47(02): 242-248
DOI: 10.4103/0970-0358.138961
Original Article
Association of Plastic Surgeons of India

A novel method for blood volume estimation using trivalent chromium in rabbit models

Authors

  • Prathap Moothamadathil Baby

    Department of Physiology, Melaka Manipal Medical College, Manipal campus, Manipal University, Karnataka, India
  • Pramod Kumar

    1   Department of Plastic Surgery, King Abdul Aziz Specialist Hospital, Al Jouf, Saudi Arabia
  • Rajesh Kumar

    2   Department of Nuclear Medicine, Kasturba Medical College, Manipal, Manipal University, Karnataka, India
  • Sanu S. Jacob

    3   Department of Physiology, Kasturba Medical College, Manipal, Manipal University, Karnataka, India
  • Dinesh Rawat

    4   Department of Nuclear Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh, India,
  • V. S. Binu

    5   Department of Statistics, Manipal Univeristy, Manipal, Karnataka, India
  • Kalesh M. Karun

    5   Department of Statistics, Manipal Univeristy, Manipal, Karnataka, India
Further Information

Address for correspondence:

Mr. Prathap Moothamadathil Baby
Department of Physiology, Melaka Manipal Medical College, Manipal campus, Manipal University
Madhav Nagar, Manipal - 576 104, Karnataka
India   

Publication History

Publication Date:
26 August 2019 (online)

 

ABSTRACT

Background: Blood volume measurement though important in management of critically ill-patients is not routinely estimated in clinical practice owing to labour intensive, intricate and time consuming nature of existing methods. Aims: The aim was to compare blood volume estimations using trivalent chromium [51 Cr(III)] and standard Evans blue dye (EBD) method in New Zealand white rabbit models and establish correction-factor (CF). Materials and Methods: Blood volume estimation in 33 rabbits was carried out using EBD method and concentration determined using spectrophotometric assay followed by blood volume estimation using direct injection of 51Cr(III). Twenty out of 33 rabbits were used to find CF by dividing blood volume estimation using EBD with blood volume estimation using 51Cr(III). CF is validated in 13 rabbits by multiplying it with blood volume estimation values obtained using 51Cr(III). Results: The mean circulating blood volume of 33 rabbits using EBD was 142.02 ± 22.77 ml or 65.76 ± 9.31 ml/kg and using 51Cr(III) was estimated to be 195.66 ± 47.30 ml or 89.81 ± 17.88 ml/kg. The CF was found to be 0.77. The mean blood volume of 13 rabbits measured using EBD was 139.54 ± 27.19 ml or 66.33 ± 8.26 ml/kg and using 51Cr(III) with CF was 152.73 ± 46.25 ml or 71.87 ± 13.81 ml/kg (P = 0.11). Conclusions: The estimation of blood volume using 51Cr(III) was comparable to standard EBD method using CF. With further research in this direction, we envisage human blood volume estimation using 51Cr(III) to find its application in acute clinical settings.


 


Conflicts of interest

None declared.


Address for correspondence:

Mr. Prathap Moothamadathil Baby
Department of Physiology, Melaka Manipal Medical College, Manipal campus, Manipal University
Madhav Nagar, Manipal - 576 104, Karnataka
India