Open Access
CC BY-NC-ND 4.0 · Indian J Plast Surg 2014; 47(02): 221-237
DOI: 10.4103/0970-0358.138956
Original Article
Association of Plastic Surgeons of India

Role of the urethral plate characters in the success of tubularized incised plate urethroplasty

Authors

  • Hamdy Aboutaleb

    1   Departments of Urology, Minoufiya University Hospitals, Egypt
    2   Departments of Urology, Mayo Hospital, Hodiedah, Yemen
Further Information

Address for correspondence:

Prof. Hamdy Aboutaleb
Department of Urology
Minoufiya University Hospitals
Egypt   

Publication History

Publication Date:
26 August 2019 (online)

 

ABSTRACT

Background: Today, tubularized incised plate (TIP) urethroplasty is the most commonly performed operation for distal and mid-penile hypospadias. Reports from different centers worldwide confirm its nearly universal applicability and low complications rate. Aim: Evaluation of the urethral plate characters and its effect on the outcome of TIP urethroplasty. Materials and Methods: Between 2010 and 2013, 100 children with primary distal penile hypospadias underwent TIP urethroplasty. Urethral plates were categorized as flat, cleft, and deeply grooved. Postoperatively, patients were followed-up for evaluation of meatal stenosis, fistula formation, and glandular dehiscence at 1 st , 3 rd and 6 th months. Patients were followed-up for urethral calibration by urethral sound 8 Fr at 3 rd and 6 months follow-up. Data were statistically analysed using Epi info program to correlate between the width, plate shape, and complications. Results: Mean age at surgery was 4.3 years. Patients were followed-up for an average period of 6.4 months. Pre-operative location of the meatus was reported as coronal in 46, subcoronal in 50 and anterior penile in 4 cases. Urethral plate characters were flat in 26 cases, cleft in 52, and deeply grooved in 22. Urethral plate width was >8 mm in 74 cases and <8 mm in 26. Patients with urethral plate <8 mm had a statistically significant higher fistula rate (P = 0.004) and failed 8 Fr calibrations in 26.9% (P = 0.01) compared with the patients with urethral plate >8 mm. In addition, we also founds higher fistula rate and failed 8 Fr calibrations in flat urethral plate. Conclusions: An adequate urethral plate width (>8 mm) is essential for successful TIP repair. Lower success rates with flat plates may need buccal mucosal augmentation to improve the results.


 


Conflicts of interest

None declared.


Address for correspondence:

Prof. Hamdy Aboutaleb
Department of Urology
Minoufiya University Hospitals
Egypt