Thromb Haemost 2005; 94(03): 680-681
DOI: 10.1160/TH05-03-0680
Case Report
Schattauer GmbH

Distal embolization during angioplasty for acute myocardial infarction: is pharmacological protection enough?

Marco De Carlo
1   Cardiovascular Department, Livorno Hospital, Italy
,
Ugo Limbruno
1   Cardiovascular Department, Livorno Hospital, Italy
,
Sabina Pistolesi
2   Department of Oncology, Transplants, and New Technologies in Medicine, University of Pisa, Italy
,
Gabriella Fontanini
2   Department of Oncology, Transplants, and New Technologies in Medicine, University of Pisa, Italy
,
Anna S. Petronio
1   Cardiovascular Department, Livorno Hospital, Italy
,
Alberto Balbarini
1   Cardiovascular Department, Livorno Hospital, Italy
,
Raffaele De Caterina
3   Institute of Cardiology and Center of Excellence on Aging, ″G. d′Annunzio“ University of Chieti, Italy
› Author Affiliations
Further Information

Publication History

Received: 08 March 2005

Accepted after major revision: 24 May 2005

Publication Date:
07 December 2017 (online)

 

 
  • References

  • 1 Lepper W. et al. Assessment of myocardial reperfusion by intravenous myocardial contrast echocardiography and coronary flow reserve after primary percutaneous transluminal coronary angioplasty in patients with acute myocardial infarction.. Circulation 2000; 101: 2368-74.
  • 2 Poli A. et al. Integrated analysis of myocardial blush and ST-segment elevation recovery after successful primary angioplasty: Real-time grading of microvascular reperfusion and prediction of early and late recovery of left ventricular function.. Circulation 2002; 106: 313-8.
  • 3 Morishima I. et al. Angiographic no-reflow phenomenon as a predictor of adverse long-term outcome in patients treated with percutaneous transluminal coronary angioplasty for first acute myocardial infarction.. J Am Coll Cardiol 2000; 36: 1202-9.
  • 4 Kotani J. et al. Plaque gruel of atheromatous coronary lesion may contribute to the no-reflow phenomenon in patients with acute coronary syndrome.. Circulation 2002; 106: 1672-7.
  • 5 Limbruno U. et al. Mechanical prevention of distal embolization during primary angioplasty: safety, feasibility, and impact on myocardial reperfusion.. Circulation 2003; 108: 171-6.
  • 6 Henriques JP. et al. Incidence and clinical significance of distal embolization during primary angioplasty for acute myocardial infarction.. Eur Heart J 2002; 23: 1112-7.
  • 7 Giri S. et al. Synergy between intracoronary stenting and abciximab in improving angiographic and clinical outcomes of primary angioplasty in acute myocardial infarction.. Am J Cardiol 2000; 86: 269-74.
  • 8 Antman EM. et al. ACC/AHA guidelines for the management of patients with ST-elevation myocardial infarction–executive summary. A report of the ACC/ AHA Task Force on Practice Guidelines.. J Am Coll Cardiol 2004; 44: 671-719.
  • 9 Stone GW. et al. Distal microcirculatory protection during percutaneous coronary intervention in acute STsegment elevation myocardial infarction: a randomized controlled trial.. JAMA 2005; 293: 1063-72.
  • 10 Kotani J. et al. Volumetric intravascular ultrasound evidence that distal embolization during acute infarct intervention contributes to inadequate myocardial perfusion grade.. Am J Cardiol 2003; 92: 728-32.
  • 11 Beran G. et al. Intracoronary thrombectomy with the X-sizer catheter system improves epicardial flow and accelerates ST-segment resolution in patients with acute coronary syndrome: a prospective, randomized, controlled study.. Circulation 2002; 105: 2355-60.
  • 12 Rinfret S. et al. Effectiveness of rheolytic coronary thrombectomy with the AngioJet catheter.. Am J Cardiol 2002; 90: 470-6.