Zenker's Diverticulum: Treatment Using a Flexible Endoscope
The aim of the Expert Approach section is to contribute to the dissemination and standardization of new endoscopie procedures. Authors from three distinct geographic areas combine forces, sharing their experience to form a consensus of opinion. Readers' comments are welcome and will be published in the Mailbox which appears at the end of each Expert Approach article.Committee:Chairman: R. Lambert (Lyon)Specialists: R. Kozarek (Seattle), H. Inoue (Tokyo), P. Sakai (Sao Paulo), H. Neuhaus (Düsseldorf), C. Neumann (Birmingham)Publication History
Publication Date:
25 October 2004 (online)

Introduction
The pharyngoesophageal diverticulum has been called Zenker's diverticulum (ZD); we define the latter as a posterior diverticulum with its neck proximal to the cricopharyngeal muscle. Most authors consider such pouches to be a type of esophageal diverticulum. Diverticula are outpouchings of one or more layers of the esophageal wall, and occur in three main areas: 1) immediately above the upper esophageal sphincter (ZD); 2) near the midpoint of the esophagus (traction diverticulum); and 3) immediately above the lower esophageal sphincter (epiphrenic diverticulum).
References
- 1
Barthlen W, Feussner H, Hannig C, et al.
Surgical therapy of Zenker's diverticulum: low risk and high efficiency.
Dysphagia.
1990;
5
13-19
MissingFormLabel
- 2
Dohlman G, Mattson O.
The endoscopic operation for hypopharyngeal diverticula: a roentgen-cinematographic
study.
Arch Otolaryngol.
1960;
71
744-752
MissingFormLabel
- 3
Van Overbeek JJ.
Meditation on the pathogenesis of hypopharyngeal (Zenker's) diverticulum and a report
of endoscopic treatment in 545 patients.
Ann Otorhinolaryngol.
1994;
103
178-185
MissingFormLabel
- 4
Collard JM, Otte JB, Kestens PJ.
Endoscopic stapling technique of esophagodiverticulostomy for Zenker's diverticulum.
Ann Thorac Surg.
1993;
56
573
MissingFormLabel
- 5
Scher RL, Richtsmeier WJ.
Long-term experience with endoscopic staple-assisted esophagodiverticulostomy for
Zenker's diverticulum.
Laryngoscope.
1998;
108
200-205
MissingFormLabel
- 6
Peracchia A, Bonavina L, Narne S, et al.
Minimally invasive surgery for Zenker diverticulum: analysis of results in 95 consecutive
patients.
Arch Surg.
1998;
133
695-700
MissingFormLabel
- 7
Philippsen LP, Weisberger EC, Whiteman TS, Schmidt JL.
Endoscopic stapled diverticulotomy: treatment of choice for Zenker's diverticulum.
Laryngoscope.
2000;
110
1283-1286
MissingFormLabel
- 8
Overbeek JJM, Hoeksema PE, Edens ET.
Microendoscopic surgery of the hypopharyngeal diverticulum using electrocoagulation
or carbon dioxide laser.
Ann Otol Rhinol Laryngol.
1984;
93
34-36
MissingFormLabel
- 9
Ishioka S, Sakai P, Maluf Filho F, Melo JM.
Endoscopic incision of Zenker's diverticulum: a new approach.
Endoscopy.
1995;
27
438-442
MissingFormLabel
- 10
Mulder CJJ, den Hartog G, Robijn RJ, Thies JE.
Flexible endoscopic treatment of Zenker's diverticulum: a new approach.
Endoscopy.
1995;
27
438-442
MissingFormLabel
- 11
Wahab PJ, Mulder CJJ, den Hartog G, Thies JE.
Argon plasma coagulation in flexible gastrointestinal endoscopy: pilot experiences.
Endoscopy.
1997;
29
176-181
MissingFormLabel
- 12
Hashiba K, de Paula AL, da Silva JGN, et al.
Endoscopic treatment of Zenker's diverticulum.
Gastrointest Endosc.
1999;
49
93-96
MissingFormLabel
- 13
Bremner CG, De Meester TR.
Endoscopic treatment of Zenker's diverticulum.
Gastrointest Endosc.
1999;
49
126-128
MissingFormLabel
C J J MulderM.D.
Dept. of Gastroenterology Rijnstate Hospital Arnhem
PO Box 9555 Arnhem 6800 TA The Netherlands
Fax: + 31-26-3786737
Email: cjmulder@rijnstate.nl
Mailbox
Readers' comments (maximum 200 words, no illustrations) on published topics are welcome, and appear here. Readers are also invited to suggest topics of interest to The Expert Approach committee. All correspondence should be addressed to R. Lambert, M.D., preferably by email. Address: International Agency for Research on Cancer, 150 cours Albert Thomas, Lyon 693 72 cedex, France. Fax: +33-4-7273-8650, email: lambert@iarc.fr.