CC BY 4.0 · Eur J Dent
DOI: 10.1055/s-0045-1809425
Original Article

Influence of Vita Enamic Hybrid Ceramic with Different Thicknesses and Translucencies on the Polymerization of Light-Cured Resin Cement: An In Vitro Study

1   Department of Clinical Dental Sciences, College of Dentistry, Ajman University, Ajman, United Arab Emirates
,
Emad S. Elsubeihi
1   Department of Clinical Dental Sciences, College of Dentistry, Ajman University, Ajman, United Arab Emirates
2   Center of Medical and Bio-Allied Health Sciences Research, Ajman University, Ajman, United Arab Emirates
› Author Affiliations
 

Abstract

Objectives

This study was conducted to evaluate the effect of the CAD/CAM (computer-aided design/computer-aided manufacturing) hybrid ceramic material (Vita Enamic, Vita Zahnfabrik, Bad Säckingen, Germany) in different thicknesses and translucencies on the light irradiance and the obtained radiant exposure, and to measure the Vickers microhardness (HV) and the degree of conversion (DC%) of the light-cured resin cement (Variolink Esthetic LC, Ivoclar Vivadent, Liechtenstein); polymerized by the Vita Enamic samples with different thicknesses and translucencies.

Materials and Methods

The study comprised the polymerization of light-cured resin cement samples through blocks of different thicknesses ranging from 1.0 to 3.0 mm, and two degrees of translucency, namely, translucent and highly translucent Vita Enamic sectional blocks. Light attenuation by the Vita Enamic sections was measured using visible light transmission spectrometry, verifying the accuracy of resin curing (MARC light collector, Bluelight Analytics, Canada). The radiant exposure (RE; in J/cm3) or the energy reaching the resin cement samples through Vita Enamic sections during polymerization as well as during polymerization of the resin cement samples directly without the interposition of Vita Enamic sections (control group) was measured. The polymerization efficiency of resin cement was evaluated by using HV and DC% of resin cement using Fourier transform infrared spectroscopy.

Statistical Analysis

The data were analyzed for normality using the Kolmogorov–Smirnov and Shapiro–Wilk tests, which indicated non-normal distribution. Non-parametric Kruskal–Wallis tests were used to determine statistical significance, with Dunn's post-hoc tests for multiple comparisons when significance was detected.Normality tests (Kolmogorov–Smirnov and Shapiro– Wilk) applied to raw data showed that the data were not normally distributed. The nonparametric Kruskal–Wallis test was used to determine statistical significance. If significance was found, multiple comparisons of the groups were tested using Dunn’s post-hoc test.

Results

The results showed a statistically significant decrease in RE (J/cm3), HV, and DC% with increasing thickness of the Vita Enamic sections. On the other hand, despite the decrease in RE (J/cm3), HV, and DC% with translucent compared with the same section thickness of the highly translucent Vita Enamic hybrid ceramic, the differences were not statistically significant.

Conclusion

Within the limitations of this study, it can be concluded that increasing the thickness of the Vita Enamic hybrid ceramic sections reduces the light irradiance and the radiant exposure received, as well as the HV and the percentage of conversion of the light-cured resin cement Variolink Esthetic LC of neutral shade. In addition, the different translucency of the Vita Enamic hybrid ceramic, namely, translucent and highly translucent, had a small but nonsignificant effect on the light irradiance and the obtained radiation, as well as on the HV and percentage of conversion of the light-cured resin cement Variolink Esthetic LC of the neutral shade.


#

Introduction

Computer-aided design/computer-aided manufacturing (CAD/CAM) restorations have become very popular in esthetic dentistry. As a result, many studies have been conducted on the durability and adhesion of such restorative materials.[1] [2] This development has significantly changed the clinical workflow scenario for both dentists and technicians.[3] One of the most important changes is the introduction of monolithic restorations made of high-strength ceramics such as zirconia, or novel ceramic microstructures that have recently been introduced, offering composite and ceramic together with optimized properties.[4] CAD/CAM composites have lower stiffness and hardness compared with ceramics, making them easier to machine using milling machines. This is also beneficial for the opposing dental tissues, which would likely be subject to less wear clinically. In addition, composites are easy to fabricate and repair, and are less brittle than ceramics, resulting in less chipping and cracking during fabrication and aging.[5] According to Mainjot et al,[6] CAD/CAM composite blocks are basically divided into two main categories based on their microstructural geometry: (1) resin with dispersed fillers; (2) polymer-infiltrated ceramic network (PICN). The first category includes composite blocks containing a base monomer type such as Bis-GMA (bisphenol A diglycidylmethacrylate), TEGDMA (triethylene glycol dimethacrylate), and UDMA (urethane dimethacrylate) as an organic matrix with dispersed filler particles such as zirconium dioxide, silicon dioxide, and/or barium glass.[7] PICN materials, on the other hand, consist of a three-dimensional ceramic network infiltrated with a monomer mixture. This blend of composite and ceramic should optimize the performance of these restorative materials by combining the modulus of elasticity of composite, which is similar to dentin, with the long-term esthetic stability of ceramic.[8] PICN is a hybrid dental material combining a sintered ceramic matrix (mostly leucite and some zirconia) with a polymer network.[9] Its flexural strength is generally superior to feldspathic porcelain but lower than lithium disilicate.[9] PICN exhibits damage tolerance to indentation better than some ceramics. Under low loads (up to 200 N), PICN shows high fatigue resistance.[10] However, under higher loads, lithium disilicate and zirconia may perform better.[10] PICN's hardness is lower than ceramics and similar to dental tissues.[11] Its bond strength to resin cements can be influenced by surface treatments, with hydrofluoric acid etching being a common recommendation, although results vary across studies.[12] [13] [14] PICN's surface roughness after milling is generally between resin composites and feldspathic porcelain.[15] Clinically, PICN crowns have shown promising short-term survival rates.[15] CAD/CAM restorations are usually cemented with resin cement.[16] The popularity of using resin cement for bonding indirect restorations to the tooth structure has increased over the years due to its advantages such as high bond strength, translucency, and shade selection in esthetic areas as well as its low solubility.[17]

The composition of the restorative material, translucency, thickness, and shade are the most important factors that can influence the light transmission and thus, the polymerization of resin cement. This finding was confirmed by Pick et al,[18] when they found that the microhardness of dual-cured resin cements was higher than that of light-cured resin cements. They showed that the light transmission through the ceramic material was not sufficient for complete polymerization of the resin and was compensated by the chemical curing in the dual-cured resin cement.[18] In another study by Kilinc et al,[16] it was reported that chemical curing in the dual-cured resin cement could not fully compensate for insufficient polymerization by light. Resin composite polymerization is a form of addition polymerization that produces no by-product. By converting monomers with carbon–carbon double bonds to carbon–carbon single bonds linking one monomer to another, a long chain and interchain crosslink is formed[19] through a process consisting of three steps: induction, propagation, and termination, which cannot be covered in this article.[20] Free radicals are formed by initiators that use either heat (chemical activation of the initiator benzoyl peroxide by tertiary amine) or light energy (either visible or ultraviolet light) to initiate polymerization. Different types of photoinitiators have been used in resin-based composites such as: (1) ultraviolet sensitive photoinitiators; (2) visible light-sensitive photoinitiators which differ in the wavelength at which they absorb light.[21] The photoinitiator Ivocerin—Dibenzoyl-Germanium—has only recently been introduced and is only available in selected products. Recently, this novel dibenzoyl-germanium-based photoinitiator has been added to dental luting cements, which have been reported to exhibit a higher degree of conversion (DC%) and color stability.[22] Inadequate polymerization of light-cured resin materials can lead to many disadvantages, such as increased wear, reduced microhardness, marginal breakdown, and increased postoperative sensitivity.[23] Accordingly, many methods have been mentioned and used in the literature to evaluate the efficacy of polymerization of dental resins, such as microhardness, optical microscopy, scraping back, and Fourier transform infrared spectroscopy (FTIR).[24] [25] Many studies have focused on investigating the photopolymerization of these cements under different types of ceramics using different techniques and different light-curing sources.[1] [2] [16] It is still unclear in the literature that light-cured resin cements can be properly by novel hybrid ceramics and to what extent the thickness or degree of translucency of these restorations may limit their use. Recently, manufacturers have introduced a new type of hybrid ceramic, namely Vita Enamic, a PICN that exhibits high mechanical performance and physical properties.[26] However, there are few studies that have investigated the attenuation of light by this type of hybrid ceramic, the radiant exposure that reaches the resin cement polymerized through this hybrid ceramic, and the efficacy of polymerization and the degree of monomer to polymer conversion of resin cement polymerized through different thicknesses and degrees of translucency of this hybrid ceramic. Therefore, studies are needed to confirm the polymerization efficiency of these Ivocerin-based resin cements through different ceramic materials including Vita Enamic hybrid ceramics.

Therefore, the objectives of this study were to (1) evaluate the effects of the thickness of Vita Enamic hybrid ceramic with different translucencies on the light irradiance and the received radiant exposure on the underside of the light-cured Ivocerin-based resin cement, (2) evaluate the microhardness of the light-cured Ivocerin-based resin cement, used under different thicknesses of Vita Enamic with different translucencies, and (3) to evaluate the DC% of the light-cured Ivocerin-based resin cements used under different thicknesses of Vita Enamic sections with different translucencies. The null hypotheses tested were (1) light irradiance and radiant exposure delivered to light-cured Ivocerin-based resin cement were not affected by increased thickness or increased translucency of the Vita Enamic hybrid ceramic. (2) The microhardness of the light-cured Ivocerin-based resin cement was not affected by the increased thickness or increased translucency of the Vita Enamic hybrid ceramic. (3) The DC% of the light-cured Ivocerin-based resin cement was not affected by increased thickness or increased translucency of the Vita Enamic hybrid ceramic.


#

Methods

The Vita Enamic material used had the shade of 1M1 and two different translucencies namely; highly Translucent (HT) and translucent (LT). For each type of Vita Enamic translucency, sections of five different thicknesses were tested. These were 1.0, 1.5, 2.0, 2.5, and 3.0 mm thick. The minimum sample size was calculated using a power analysis (n = 10/group). In addition, light-curing was performed without interposition of the Vita Enamic sections and used as a control group resulting in 11 groups. The study design is shown in [Fig. 1]. The compositions of the investigated CAD/CAM block material and the light-cured resin cement are summarized in [Table 1]. The study design involved the polymerization of light-cured resin cement samples through various thicknesses and translucency levels of Vita Enamic sections using an LED light-curing unit (BluePhase N, Ivoclar Vivadent, Liechtenstein). The attenuation of light by the Vita Enamic sections was measured using visible light transmission spectrometry (MARC light collector, Blue-light Analytics, Canada), the radiant exposure (J/cm3), or the energy reaching the resin cement samples through the Vita Enamic sections during polymerization, and LED polymerization of resin cement samples directly without the interposition of Vita Enamic sections. The efficiency of the resin cement polymerization, Vickers microhardness (HV), and the DC% of the resin cement were evaluated using FTIR.

Zoom Image
Fig. 1 Study design. The figure shows number of hybrid ceramic slabs, number of resin cement films in each group, and tests applied.
Table 1

Composition of the materials used in this study

Material

Manufacturer

Classification

Composition

Lot number

Vita Enamic Shade 1M1 (A1) HT, T

VITA Zahnfabrik, Bad Säckingen, Germany

Hybrid ceramic

Aluminum oxide-enriched, fine-structure feldspar matrix (86 wt%, 75 vol%) infused by a polymer material consisting of UDMA and TEGDMA (14 wt%, 25 vol%)

75410

Variolink Esthetic LC (Neutral)

Ivoclar Vivadent, Schaan, Liechtenstein

Light-cured resin cement

Ytterbium trifluoride (10–25%)

1,10-decanediol dimethacrylate (3–10%)

Urethane dimethacrylate (3–10%)

666129

Sample Size Determination

The sample size of each group was estimated using data available in the literature.[27] The means and standard deviations reported in the literature by Yan et al, were used to estimate the sample size using GPower with the formula: . This revealed that 12 samples in each group were required to ensure a 5% level of significance ([Fig. 2] and [2A]).

Zoom Image
Fig. 2 The figure shows the subjects needed to conduct the current study. (A) Details of sample size calculations.

#

Production of Hybrid Ceramic Samples

HT and LT Vita Enamic (Vita Zahnfabrik, Bad Säckingen, Germany) CAD/CAM blocks measuring 12 × 14 × 18 mm (shade 1M1) were cut in slabs with a thickness of 1.0, 1.5, 2.0, 2.5, and 3.0 mm using an automated water-cooled low-speed diamond saw (Precision SAW; IsoMet1000, Serial number 713-IPS-04427, BUEHLER, United States).

The resulting Vita Enamic slabs were polished using a grinder and polisher device (MetaServ 250 [twin Grinder-Polisher], serial number 711-MGT-00575, BUEHLER, United States).

The thickness of the hybrid ceramic slabs was then checked using digital caliper (INSIZE Co., LTD) and the desired thickness (±0.01) was ascertained using laser scanning micrometer (LSM-503s, Mitutoyo America Corporation; [Fig. 3]).

Zoom Image
Fig. 3 The hybrid ceramic slabs' thicknesses (± 0.01) checked by using Digital Caliper (INSIZE Co., LTD) (A); desired 1 mm thickness of hybrid ceramic measured with digital caliper (B); desired 2 mm thickness of hybrid ceramic measured with digital caliper (C); desired 3 mm thickness of hybrid ceramic measured with digital caliper (D); 3 mm thickness slab of hybrid ceramic ascertained using laser scan micrometer (LSM-503s, Mitutoyo America Corporation) (E).

#

Preparation of Specimens of Light-Cured Resin Cement

A light-cured resin cement (Variolink Esthetic LC, Ivoclar Vivadent, Liechtenstein) in neutral shade was used in this study. The prepared thickness of the cement was 50 µm in accordance with ISO 4049–2019[28] for the maximum film thickness of luting materials. This thickness was achieved using the following technique. A Mylar strip was placed on the sensor of the MARC resin calibrator, with two perpendicular Mylar strips placed on each end of the base strip. A small drop of cement was placed between the two strips on the base strip. Next, a fourth Mylar strip was placed over the cement drop and the two vertical strips. Then a 50 g weight was placed over the entire unit (the Mylar strips and the cement) for 15 seconds so that the resin cement was compressed to the thickness of the two vertical Mylar strips, which was 50 microns. After the weight was removed, the hybrid ceramic slab was placed on the cement sample unit. A putty silicone light probe jig was then fabricated around the tip of the LED light-curing unit (BluePhase N, Ivoclar Vivadent, Liechtenstein) which was positioned exactly in the center of the hybrid ceramic slab to ensure that the light probe of the light-curing unit was placed in the same position for different hybrid ceramic slabs and resin cement samples. Each group consisted of 12 light-cured resin cement films, resulting in a total of 132 light-cured resin cement films for radiant exposure (J/cm3) testing, 132 light-cured resin cement films for microhardness value testing, and 132 light-cured resin cement films for FTIR testing the DC%.


#

Light Exposure Time

In this study, an LED light-curing Unit (BluePhase N, Ivoclar Vivadent, Liechtenstein) with a wavelength range of 430 to 490 nm and a light intensity of 1,200 mW/cm2, equipped with a 10 mm curved light probe, was used. In the manufacturer's instructions, the curing time of Variolink Esthetic LC (Ivoclar Vivadent, Liechtenstein) is specified as 10 seconds per millimeter of ceramic. The manufacturer of Vita Enamic recommends the use of a high-power LED, therefore 10–15–20–25–30 seconds of high-power LED with 1,200 mW/cm2 intensity was chosen for this study depending on the thickness of ceramic being used.


#

Measurement of Light Attenuation by the Hybrid Ceramic Slabs

The experiment was performed using light transmission spectrometry in the visible range (MARC light collector, Bluelight Analytics, Canada). The sensor in the MARC resin calibrator is connected to a spectrometer. The spectrometer was used to measure both the irradiance and spectral irradiance of the light source alone and through different Vita Enamic hybrid ceramic slabs ([Figs. 4] and [5]). The silicone light probe guide was used on all samples to ensure the central position of the light probe over each sample. The radiant exposure of resin cement samples polymerized under different hybrid ceramic slabs and through the cement sample directly without interposing a hybrid ceramic slab between the light source and the resin cement sample (control group) was recorded by the spectrometer. The radiant exposure (J/cm3) is the total area under the spectral curve in the corresponding graph of each test. The information is calculated and automatically stored in the software.

Zoom Image
Fig. 4 Graph demonstrates the irradiance (mW/cm2) delivered to the sensor on the MARC during the time period of light exposure.
Zoom Image
Fig. 5 Graph demonstrates the irradiance (mW/cm2) delivered to the sensor through all samples of different thicknesses and translucencies on the MARC during the time period of light exposure.

After curing with LED light, the samples were kept between the Mylar strips, the bottom surface of each film was marked, and the entire unit of Mylar strips and resin cement samples was stored for 24 hours at 37°C in an incubator in a dark environment.


#

Measuring the Polymerization Efficiency of Light-Cured Resin Cements by Microhardness

The standard test method for Knoop and Vickers hardness (HV) of materials (ASTM (E384–11–1) recommends that the load must be such that the penetration depth of the pyramid into the coating is no more than 1/10 of the coating thickness. Therefore, the appropriate indentation force for the 50-micron thick sample during the microhardness test was calculated using the formula d = 7t, where d = mean diagonal length and t = penetration depth. Each sample was tested for HV using a microhardness tester (Future-Tech Corp., model FM-800, serial number FMX8346, Japan) with a Vickers indenter with a force of 5 ngF and 10 seconds dwell time ([Table 2]).

Table 2

Comparison of the indentations produced with three different test loads (5, 10, and 25 gF) on specimens that were cured through the thickest low translucent hybrid ceramic slab (translucent: 3 mm thick)

1M1 T 3 mm

5 g

10 g

25 g

Resin cement specimen

of 50-micron thickness

Penetration depth

5.4 µm

9.5 µm

17.5 µm


#

Measurement of the Degree of Conversion

The samples were analyzed using FTIR (IRAffinity-1S, Shimadzu Corp., Japan) with an attenuated total reflectance (ATR) measurement accessory to determine the DC%. The FTIR spectra were collected for a sample of unreacted monomer as well as for the polymerized samples through Vita Enamic slabs. The measurements of the DC% were performed at 22°C (room temperature) and at a relative humidity of 50% to avoid premature setting of the cement due to ambient light. The infrared spectra were acquired from the bottom of the sample in the wavelength range of 4,000–500 cm−1, a wavenumber resolution of 4 cm−1, and a rate of 45 scans/spectrum as measurement parameters in absorbance mode. A single measurement was performed for each of the 132 samples. As a negative control, a drop of uncured cement was applied to the ATR crystal and infrared spectra were recorded from the underside of the sample without light irradiation to determine the chemical curing of the composite cement. The DC% was calculated from the aliphatic C = C peak at 1,638 cm−1 and normalized against the aromatic C = C peak at 1,608 cm−1, using the following equation:

DC% = [1 − (A 1,638/A 1,608)cured/(A 1,638/A 1,608)uncured] × 100

where:

  • A1638A_ {1638}A1638 = absorbance of the aliphatic C = C bond at 1,638 cm−1.

  • A1608A_ {1608}A1608 = absorbance of the aromatic C = C bond at 1,608 cm−1.

  • The subscript “cured” refers to the polymerized specimen, and “uncured” refers to the unpolymerized material.

The conversion level of each sample was calculated as a percentage.


#
#

Results

Measured Variables

The variables measured in this study included the radiant exposure (J/cm3), microhardness, and the DC% of light-cured cement (Variolink Esthetic LC) cured under different thicknesses (1.0, 1.5, 2.0, 2.5, and 3.0 mm) of thick slabs with the translucency levels (HT, T) and shade 1M1. Eleven groups including the control group were evaluated for each variable.


#

Statistical Analysis

Normality tests (Kolmogorov–Smirnov and Shapiro–Wilk) were applied to the raw data. The analysis of the normality tests showed that the data were not normally distributed. Nonparametric tests were used to test for statistical significance. Radiant exposure, microhardness value, and DC% were analyzed using the nonparametric test (Kruskal–Wallis). If a significant difference was found between the groups, multiple comparisons of the groups were revealed using the Dunn's test. A p-value of ≤0.05 was considered statistically significant. Statistical analysis was performed using SPSS (version 21, 64-bit edition, IBM, United States).


#

Comparison of Radiant Exposure (J/cm3), Microhardness, and Degree of Conversion between All Groups

The mean values and standard deviations of radiant exposure (microhardness and DC%—after 24 hours of incubation at 37°C) of the control group and for the samples polymerized under (1.0, 1.5, 2.0, 2.5, and 3.0 mm) HT and LT are shown in ([Tables 3] [4] [5]).

Table 3

Descriptive statistics of radiant exposure (in J/cm3) of all groups tested

Sample No.

High translucency

Low translucency

Control

Thickness of hybrid ceramic

Thickness of hybrid ceramic

1.0 mm

1.5 mm

2.0 mm

2.5 mm

3.0 mm

1.0 mm

1.5 mm

2.0 mm

2.5 mm

3.0 mm

1

9

5.77

3.72

2.61

1.81

7.25

3.47

2.29

2.27

1.6

15.98

2

7.6

4.46

3.67

2.56

2.22

6.82

3.53

2.58

2.13

1.52

22.14

3

9.42

5.25

3.65

2.22

2.24

6.18

2.36

2.38

2.24

1.28

15.35

4

8.75

5.59

3.61

2.26

1.39

6.29

2.17

2.53

2.02

1.43

21.94

5

8.92

5.3

3.95

2.45

2.16

6.98

2.31

2.69

2.05

1.43

23.15

6

8.74

5.07

3.81

2.48

1.98

6.62

2.31

2.57

2.09

1.28

17.54

7

8.99

4.97

3.31

2.47

1.31

6.98

2.37

2.4

1.86

1.22

17.45

8

8.33

5.1

3.53

2.38

1.35

7.17

2.48

2.64

2.03

1.3

15.26

9

7.96

4.99

3.59

2.33

1.81

7.24

2.43

2.5

1.89

1.44

16.34

10

8.54

4.17

3.5

2.51

1.95

6.12

2.25

2.62

1.97

1.26

20.56

11

9.77

5.66

3.59

2.47

1.67

7.5

2.87

2.5

1.78

1.31

18.45

12

8.54

6.72

3.24

2.59

1.89

5.9

2.55

2.3

2.06

1.32

16.91

Mean

8.713

5.254

3.597

2.444

1.815

6.754

2.591

2.5

2.032

1.365

18.422

SD

0.590

0.654

0.194

0.124

0.328

0.523

0.459

0.131

0.1449

0.116

2.810

Abbreviation: SD, standard deviation.


Table 4

Descriptive statistics of microhardness value (HV) of all groups tested

Sample No.

High translucency (HT)

Translucent (LT)

Control

Thickness of hybrid ceramic

Thickness of hybrid ceramic

1.0 mm

1.5 mm

2.0 mm

2.5 mm

3.0 mm

1.0 mm

1.5 mm

2.0 mm

2.5 mm

3.0 mm

1

8.6

6.3

4.8

4

4.7

7.7

7.1

4.7

2.3

5.8

8.5

2

4.4

4.6

5.4

6.2

5.8

5.6

4.6

5

3.9

3.1

9.8

3

8.1

5.2

4.3

4.4

4.4

6.4

5

5

5.5

3.4

8.5

4

9

4.4

5.5

4.1

4.4

6.4

6.8

5.1

6.8

3

9.3

5

8.9

6

5.9

4.9

5.7

7.2

3.6

4.5

3.2

2.8

7.9

6

8.7

4.3

4.6

4.8

4.2

5.2

4.3

4.9

6.4

3.4

8

7

6.9

5.9

5.7

4.7

4.6

8.3

3.9

5.5

4.4

1.5

8.1

8

8.4

6.5

5.5

5.8

3.4

10

5.7

5.6

3.2

3

10

9

6.8

6

5.3

5.1

4.1

7.2

3.6

5.4

4.3

3.2

8.7

10

5.3

5.5

5.5

5.5

2.7

7.8

3.6

4.5

5

6.2

9.3

11

6

6.4

5.7

6.3

3.7

6

7.8

4.4

6.4

5.6

7.9

12

5.9

6.5

5.5

5

4

6.2

5.1

5.1

7.2

2.5

7.3

Mean

7.25

5.633

5.308

5.066

4.308

7

5.091

4.975

4.883

3.625

8.608

SD

1.577

0.822

0.485

0.755

0.871

1.330

1.465

0.398

1.593

1.447

0.836

Abbreviation: SD, standard deviation.


Table 5

Descriptive statistics of percent degree of conversion (DC%) of all groups tested

Sample No.

High translucency

Low translucency

Control

Thickness of hybrid ceramic

Thickness of hybrid ceramic

1.0 mm

1.5 mm

2.0 mm

2.5 mm

3.0 mm

1.0 mm

1.5 mm

2 mm

2.5 mm

3.0 mm

1

83

74.3

66.8

41.9

35.3

89.3

63.6

54.5

32.3

15.5

95.3

2

79.7

67.2

53.7

28.4

25.6

79.7

71.8

55.4

35.2

20

96.7

3

91.7

69.6

85.9

35.4

33.1

78.4

73

67.8

22.9

26.6

94.4

4

81

67.9

69.4

36.8

28

88.4

67.9

63.4

35.2

30.5

95.6

5

83.2

87.5

71.2

31.4

35.6

84.7

77.2

61

20.1

26.1

95.6

6

93.5

74.8

62.7

32

29.8

89.3

74.3

56.6

26

24.4

93.5

7

88

84.4

54.3

39.2

23

84.2

71.8

59.5

26

20.2

97.8

8

83.5

83.7

62.2

28.5

21.3

80.4

75.1

69.9

20

20.7

96.7

9

87.6

80.6

65.4

31.3

37.3

87.5

77.2

56.4

38.3

23.1

93.7

10

86.1

71.2

52.8

31.6

30.2

88.3

71.8

62.9

25.9

21.7

94.9

11

88.6

62.6

75.2

38.1

23.2

88.3

73.1

58.8

29.2

19.4

95.3

12

78.2

66.9

71.6

31.1

22.9

74.8

60.1

53.3

36.2

19.1

93.7

Mean

85.34

74.22

65.93

33.80

28.77

84.44

71.40

59.95

28.94

22.27

95.266

SD

4.724

8.085

9.720

4.363

5.633

4.958

5.188

5.242

6.404

4.075

1.337

Abbreviation: SD, standard deviation.


The Kruskal–Wallis statistics showed a highly significant difference between the tested groups for radiant exposure and microhardness as well as for the DC% (p = 0.0001). Multiple comparisons of the groups were revealed by Dunn's post-hoc tests.

A significant reduction in radiant exposure was found between 1.0 mm and all other thicknesses (1.5, 2.0, 2.5, and 3.0 mm) of hybrid ceramic.

Within the two (HT, T) groups, no significant difference was found between the 1.0 mm thick hybrid ceramic and the control group in terms of radiant exposure, microhardness, and DC (p = 0.118, p = 0.161, p = 0.187), respectively. Radiant exposure (J/cm3), HV, and DC decreased with increasing thickness. Despite the fact that radiant exposure, HV, and DC decreased with increasing thickness from 2.0 to 2.5 mm and with increasing thickness from 2.5 to 3.0 mm, the differences were not statistically significant ([Tables 6] [7] [8] [9] [10] [11]).

Table 6

Dunn's statistic results of comparison of radiant exposure (J/cm3) based on thickness among high translucency hybrid ceramic group based on Dunn's statistics

Sample

Test statistic

Std. error

Std. test statistic

Sig.

Thickness 3.0 mm HT

2.5 mm HT

19.625

15.615

1.257

0.209

2.0 mm HT

49.417

15.615

3.165

0.002

1.5 mm HT

45.208

15.615

2.895

0.004

1.0 mm HT

94.208

15.615

6.033

0.000

Control

118.625

15.615

7.597

0.000

Thickness 2.5 mm HT

3.0 mm HT

19.625

15.615

1.257

0.209

2.0 mm HT

29.792

15.615

1.908

0.056

1.5 mm HT

25.583

15.615

1.638

0.001

1.0 mm HT

74.583

15.615

4.776

0.000

Control

99.000

15.615

6.340

0.000

Thickness 2.0 mm HT

3.0 mm HT

49.417

15.615

3.165

0.002

2.5 mm HT

29.792

15.615

1.908

0.056

1.5 mm HT

−4.208

15.615

−0.270

0.009

1.0 mm HT

44.792

15.615

2.869

0.004

Control

69.208

15.615

4.432

0.000

Thickness 1.5 mm HT

3.0 mm HT

45.208

15.615

2.895

0.004

2.5 mm HT

25.583

15.615

1.638

0.001

2.0 mm HT

−4.208

15.615

−0.270

0.009

1.0 mm HT

49.000

15.615

3.138

0.002

Control

73.417

15.615

4.702

0.000

Thickness 1.0 mm HT

3.0 mm HT

94.208

15.615

6.033

0.000

2.5 mm HT

74.583

15.615

4.776

0.000

2.0 mm HT

44.792

15.615

2.869

0.004

1.5 mm HT

49.000

15.615

3.138

0.002

Control

24.417

15.615

1.564

0.118

Table 7

Dunn's statistic results of comparison of radiant exposure (J/cm3) based on thickness among low translucency hybrid ceramic group based on Dunn's statistics

Sample

Test statistic

Std. error

Std. test statistic

Sig.

Thickness 3.0 mm LT

2.5 mm LT

31.875

15.615

2.041

0.241

2.0 mm LT

57.125

15.615

3.658

0.000

1.5 mm LT

70.000

15.615

4.483

0.000

1.0 mm LT

93.583

15.615

5.993

0.000

Control

105.583

15.615

6.762

0.000

Thickness 2.5 mm LT

3.0 mm LT

31.875

15.615

2.041

0.241

2.0 mm LT

25.250

15.615

1.617

0.106

1.5 mm LT

38.125

15.615

2.442

0.015

1.0 mm LT

61.708

15.615

3.952

0.000

Control

73.708

15.615

4.720

0.000

Thickness 2.0 mm LT

3.0 mm LT

57.125

15.615

3.658

0.000

2.5 mm LT

25.250

15.615

1.617

0.106

1.5 mm LT

12.875

15.615

0.825

0.041

1.0 mm LT

36.458

15.615

2.335

0.020

Control

48.458

15.615

3.103

0.002

Thickness 1.5 mm LT

3.0 mm LT

70.000

15.615

4.483

0.000

2.5 mm LT

38.125

15.615

2.442

0.015

2.0 mm LT

12.875

15.615

0.825

0.041

1.0 mm LT

53.893

15.615

2.098

0.000

Control

75.578

15.615

4.980

0.000

Thickness 1.0 mm LT

3.0 mm LT

93.583

15.615

5.993

0.000

2.5 mm LT

61.708

15.615

3.952

0.000

2.0 mm LT

12.875

15.615

0.825

0.041

1.5 mm LT

53.893

15.615

2.098

0.000

Control

24.417

15.615

1.564

0.118

Table 8

Dunn's statistic results of comparison of microhardness values (HV) based on thickness among high translucency (HT) Vita Enamic hybrid ceramic groups

Sample

Test statistic

Std. error

Std. test statistic

Sig.

Thickness 3.0 mm HT

2.5 mm HT

26.292

15.609

1.684

0.092

2.0 mm HT

25.958

15.609

1.663

0.096

1.5 mm HT

27.583

15.609

1.767

0.008

1.0 mm HT

73.667

15.609

4.719

0.000

Control

95.542

15.609

6.121

0.000

Thickness 2.5 mm HT

3.0 mm HT

26.292

15.609

1.684

0.092

2.0 mm HT

−0.333

15.609

−0.021

0.983

1.5 mm HT

1.292

15.609

0.083

0.034

1.0 mm HT

47.375

15.609

3.035

0.002

Control

69.250

15.609

4.436

0.000

Thickness 2.0 mm HT

3.0 mm HT

25.958

15.609

1.663

0.096

2.5 mm HT

−0.333

15.609

−0.021

0.983

1.5 mm HT

1.625

15.609

0.104

0.017

1.0 mm HT

47.708

15.609

3.056

0.002

Control

69.583

15.609

4.458

0.000

Thickness 1.5 mm HT

3.0 mm HT

27.583

15.609

1.767

0.008

2.5 mm HT

1.292

15.609

0.083

0.034

2.0 mm HT

1.625

15.609

0.104

0.017

1.0 mm HT

46.083

15.609

2.952

0.003

Control

67.958

15.609

4.354

0.000

Thickness 1.0 mm HT

3.0 mm HT

73.667

15.609

4.719

0.000

2.5 mm HT

47.375

15.609

3.035

0.002

2.0 mm HT

47.708

15.609

3.056

0.002

1.5 mm HT

46.083

15.609

2.952

0.003

Control

21.875

15.609

1.401

0.161

Table 9

Dunn's statistic results of comparison of microhardness values (HV) based on thickness among translucent (LT) Vita Enamic hybrid ceramic groups

Sample

Test statistic

Std. error

Std. test statistic

Sig.

Thickness 3.0 mm LT

2.5 mm LT

20.458

15.609

1.311

0.190

2.0 mm LT

28.208

15.609

1.807

0.071

1.5 mm LT

38.792

15.609

2.485

0.013

1.0 mm LT

66.500

15.609

4.260

0.000

Control

87.042

15.609

5.576

0.000

Thickness 2.5 mm LT

3.0 mm LT

20.458

15.609

1.311

0.190

2.0 mm LT

7.750

15.609

0.496

0.020

1.5 mm LT

18.333

15.609

1.175

0.024

1.0 mm LT

46.042

15.609

2.950

0.003

Control

66.583

15.609

4.266

0.000

Thickness 2.0 mm LT

3.0 mm LT

28.208

15.609

1.807

0.071

2.5 mm LT

7.750

15.609

0.496

0.020

1.5 mm LT

10.583

15.609

0.678

0.050

1.0 mm LT

38.292

15.609

2.453

0.014

Control

58.833

15.609

3.769

0.000

Thickness 1.5 mm LT

3.0 mm LT

38.792

15.609

2.485

0.013

2.5 mm LT

18.333

15.609

1.175

0.024

2.0 mm LT

10.583

15.609

0.678

0.050

1.0 mm LT

27.708

15.609

1.775

0.046

Control

48.250

15.609

3.091

0.002

Thickness 1.0 mm LT

3.0 mm LT

66.500

15.609

4.260

0.000

2.5 mm LT

46.042

15.609

2.950

0.003

2.0 mm LT

38.292

15.609

2.453

0.014

1.5 mm LT

27.708

15.609

1.775

0.046

Control

20.542

15.609

1.316

0.188

Table 10

Dunn's statistic results of comparison of percent degree of conversion (DC%) based on thickness among high translucency Vita Enamic hybrid ceramic groups

Sample

Test statistic

Std. error

Std. test statistic

Sig.

Thickness 3.0 mm HT

2.5 mm HT

13.792

15.615

0.883

0.377

2.0 mm HT

48.458

15.615

3.103

0.002

1.5 mm HT

68.958

15.615

4.416

0.000

1.0 mm HT

94.417

15.615

6.047

0.000

Control

115.000

15.615

7.365

0.000

Thickness 2.5 mm HT

3.0 mm HT

13.792

15.615

0.883

0.377

2.0 mm HT

34.667

15.615

2.220

0.066

1.5 mm HT

55.167

15.615

3.533

0.000

1.0 mm HT

80.625

15.615

5.163

0.000

Control

101.208

15.615

6.482

0.000

Thickness 2.0 mm HT

3.0 mm HT

48.458

15.615

3.103

0.002

2.5 mm HT

34.667

15.615

2.220

0.066

1.5 mm HT

20.500

15.615

1.313

0.009

1.0 mm HT

45.958

15.615

2.943

0.003

Control

66.542

15.615

4.261

0.000

Thickness 1.5 mm HT

3.0 mm HT

68.958

15.615

4.416

0.000

2.5 mm HT

55.167

15.615

3.533

0.000

2.0 mm HT

20.500

15.615

1.313

0.009

1.0 mm HT

20.517

15.615

1.987

0.018

Control

41.917

15.615

2.684

0.007

Thickness 1.0 mm HT

3.0 mm HT

94.417

15.615

6.047

0.000

2.5 mm HT

80.625

15.615

5.163

0.000

2.0 mm HT

45.958

15.615

2.943

0.003

1.5 mm HT

20.517

15.615

1.987

0.018

Control

20.583

15.615

1.318

0.187

Table 11

Dunn's statistic results of comparison of percent degree of conversion (DC%) based on thickness among translucent (LT) Vita Enamic hybrid ceramic groups

Sample

Test statistic

Std. error

Std. test statistic

Sig.

Thickness 3.0 mm LT

2.5 mm LT

10.708

15.615

0.686

0.493

2.0 mm LT

44.583

15.615

2.855

0.004

1.5 mm LT

59.250

15.615

3.794

0.003

1.0 mm LT

81.125

15.615

5.195

0.000

Control

101.167

15.615

6.479

0.000

Thickness 2.5 mm LT

3.0 mm LT

10.708

15.615

0.686

0.493

2.0 mm LT

33.875

15.615

2.169

0.030

1.5 mm LT

48.542

15.615

3.109

0.002

1.0 mm LT

70.417

15.615

4.510

0.000

Control

90.458

15.615

5.793

0.000

Thickness 2.0 mm LT

3.0 mm LT

44.583

15.615

2.855

0.004

2.5 mm LT

33.875

15.615

2.169

0.030

1.5 mm LT

14.667

15.615

0.939

0.035

1.0 mm LT

36.542

15.615

2.340

0.019

Control

56.583

15.615

3.624

0.000

Thickness 1.5 mm LT

3.0 mm LT

59.250

15.615

3.794

0.003

2.5 mm LT

48.542

15.615

3.109

0.002

2.0 mm LT

14.667

15.615

0.939

0.035

1.0 mm LT

20.517

15.615

1.987

0.018

Control

41.917

15.615

2.684

0.007

Thickness 1.0 mm LT

3.0 mm LT

81.125

15.615

5.195

0.000

2.5 mm LT

70.417

15.615

4.510

0.000

2.0 mm LT

36.542

15.615

2.340

0.019

1.5 mm LT

20.517

15.615

1.987

0.018

Control

20.042

15.615

1.284

0.199

Comparison of the corresponding thickness of LT and HT Vita Enamic demonstrated that there was decreased radiant exposure in LT as compared with HT Vita Enamic of radiant exposure passing through the same corresponding section thickness. Furthermore, as the thickness of LT was increased to 2.0, 2.5, and 3.0 mm, the radiant exposure was reduced in comparison to the corresponding HT thicknesses, but the differences did not reach statistical significance ([Table 12] and [Fig. 6]).

Table 12

Dunn's statistic results of comparison of radiant exposure (J/cm3) among high translucent (HT) and translucent (LT) Vita Enamic hybrid ceramic groups

Sample

Test statistic

Std. error

Std. test statistic

Sig.

Thickness 3.0 mm LT

3.0 mm HT

13.042

15.615

0.835

0.404

2.5 mm HT

22.436

15.615

3.593

0.304

2.0 mm HT

50.581

15.615

6.483

0.008

1.5 mm HT

47.248

15.615

3.815

0.003

1.0 mm HT

106.625

15.615

6.828

0.000

Thickness 2.5 mm LT

3.0 mm HT

24.951

15.615

2.098

0.324

2.5 mm HT

25.292

15.615

1.620

0.105

2.0 mm HT

31.908

15.615

2.091

0.068

1.5 mm HT

27.502

15.615

2.937

0.003

1.0 mm HT

75.745

15.615

4.987

0.000

Thickness 2.0 mm LT

3.0 mm HT

54.581

15.615

2.098

0.006

2.5 mm HT

23.512

15.615

1.309

0.113

2.0 mm HT

20.750

15.615

1.329

0.184

1.5 mm HT

13.093

15.615

1.072

0.034

1.0 mm HT

445.809

15.615

3.009

0.000

Thickness 1.5 mm LT

3.0 mm HT

65.203

15.615

3.980

0.000

2.5 mm HT

35.798

15.615

2.304

0.016

2.0 mm HT

36.145

15.615

3.109

0.004

1.5 mm HT

37.833

15.615

2.423

0.015

1.0 mm HT

50.809

15.615

3.245

0.000

Thickness 1.0 mm LT

3.0 mm HT

101.034

15.615

4.209

0.000

2.5 mm HT

59.642

15.615

3.509

0.000

2.0 mm HT

34.723

15.615

2.795

0.000

1.5 mm HT

53.532

15.615

1.903

0.000

1.0 mm HT

12.000

15.615

0.795

0.427

Zoom Image
Fig. 6 Boxplots of radiant exposure data (in J/cm3) of 50-micron thickness light-cured resin cement polymerized without interposition of hybrid ceramic slab (control), and light-cured resin cement polymerized under 1.0, 1.5, 2.0, 2.5, and 3.0 mm of hybrid ceramic slab of translucent (LT) and highly translucent (HT) types.

Comparison of the corresponding thickness of LT and HT Vita Enamic demonstrated that there was decreased HV in LT as compared with HT Vita Enamic. Furthermore, analysis revealed no statistical significance between 1.0 mm HT and 1.0 mm LT hybrid ceramic (p = 0.427), as the thickness of LT was increased to1.5, 2.0, 2.5, and 3.0 mm, the HV was reduced in comparison to the corresponding HT thicknesses, but the differences did not reach statistical significance ([Table 13] and [Fig. 7]).

Table 13

Dunn's statistic results of comparison of microhardness values (HV) among high (HT) and translucent (LT) hybrid ceramic groups

Sample

Test statistic

Std. error

Std. test statistic

Sig.

Thickness 3.0 mm LT

3.0 mm HT

8.500

15.609

0.545

0.586

2.5 mm HT

27.498

15.609

2.698

0.085

2.0 mm HT

26.734

15.609

4.709

0.084

1.5 mm HT

28.091

15.609

1.907

0.005

1.0 mm HT

75.309

15.609

2.709

0.000

Thickness 2.5 mm LT

3.0 mm HT

28.479

15.609

2.179

0.113

2.5 mm HT

2.667

15.609

0.171

0.864

2.0 mm HT

12.409

15.609

4.309

0.073

1.5 mm HT

2.209

15.609

2.609

0.023

1.0 mm HT

48.409

15.609

3.409

0.000

Thickness 2.0 mm LT

3.0 mm HT

27.495

15.609

3.156

0.067

2.5 mm HT

14.389

15.609

1.361

0.081

2.0 mm HT

10.750

15.609

0.689

0.491

1.5 mm HT

12.498

15.609

1.980

0.014

1.0 mm HT

45.298

15.609

2.709

0.003

Thickness 1.5 mm LT

3.0 mm HT

30.798

15.609

2.798

0.034

2.5 mm HT

17.491

15.609

3.456

0.012

2.0 mm HT

9.587

15.609

3.298

0.042

1.5 mm HT

19.708

15.609

1.263

0.207

1.0 mm HT

47.260

15.609

2.471

0.000

Thickness 1.0 mm LT

3.0 mm HT

74.719

15.609

2.398

0.000

2.5 mm HT

43.723

15.609

2.109

0.004

2.0 mm HT

35.812

15.609

2.718

0.004

1.5 mm HT

26.334

15.609

4.611

0.000

1.0 mm HT

10.441

15.609

3.654

0.427

Zoom Image
Fig. 7 Boxplots of microhardness value (HV) of 50-micron thickness light-cured resin cement polymerized without interposition of hybrid ceramic slab (control), and light-cured resin cement polymerized under 1.0, 1.5, 2.0, 2.5, and 3.0 mm of hybrid ceramic slab of translucent and highly translucent types.

Comparison of the corresponding thickness of LT and HT Vita Enamic demonstrated that there was decreased DC% in LT as compared with HT Vita Enamic. Furthermore, analysis revealed no statistical significance between 1.0 mm HT and 1.0 mm LT hybrid ceramic (p = 0.972), as the thickness of LT was increased to1.5, 2.0, 2.5, and 3.0 mm, the DC% was reduced in comparison to the corresponding HT thicknesses, but the differences did not reach statistical significance ([Table 14] and [Fig. 8]).

Table 14

Dunn's statistic results of comparison of percent degree of conversion (DC%) among high translucent (HT) and translucent (LT) Vita Enamic hybrid ceramic groups

Sample

Test statistic

Std. error

Std. test statistic

Sig.

Thickness 3.0 mm LT

3.0 mm HT

13.833

15.615

0.886

0.376

2.5 mm HT

12.467

15.615

1.109

0.264

2.0 mm HT

50.679

15.615

4.065

0.002

1.5 mm HT

65.721

15.615

4.310

0.003

1.0 mm HT

94.958

15.615

6.081

0.000

Thickness 2.5 mm LT

3.0 mm HT

9.498

15.615

1.690

0.531

2.5 mm HT

10.750

15.615

0.688

0.491

2.0 mm HT

32.530

15.615

3.645

0.070

1.5 mm HT

56.734

15.615

4.923

0.000

1.0 mm HT

79.432

15.615

3.999

0.000

Thickness 2.0 mm LT

3.0 mm HT

43.209

15.615

3.154

0.004

2.5 mm HT

30.439

15.615

4.078

0.078

2.0 mm HT

10.091

15.615

2.012

0.076

1.5 mm HT

22.299

15.615

2.943

0.009

1.0 mm HT

32.600

15.615

1.980

0.000

Thickness 1.5 mm LT

3.0 mm HT

45.309

15.615

3.113

0.000

2.5 mm HT

45.609

15.615

3.961

0.019

2.0 mm HT

3.965

15.615

2.090

0.041

1.5 mm HT

4.125

15.615

0.264

0.792

1.0 mm HT

26.465

15.615

2.534

0.009

Thickness 1.0 mm LT

3.0 mm HT

79.054

15.615

2.908

0.000

2.5 mm HT

69.187

15.615

4.509

0.000

2.0 mm HT

13.465

15.615

1.980

0.009

1.5 mm HT

20.517

15.615

1.987

0.018

1.0 mm HT

0.542

15.615

0.035

0.972

Zoom Image
Fig. 8 Boxplots of degree of conversion percentage (%DC) of 50-micron thickness light-cured resin cement polymerized without interposition of hybrid ceramic slab (control), and light-cured resin cement polymerized under 1.0, 1.5, 2.0, 2.5, and 3.0 mm of hybrid ceramic slabs of translucent and highly translucent types.

#
#

Discussion and Conclusion

The main purpose of this study was a comparative evaluation of the polymerization efficiency of light-curing resin cement containing the novel photoinitiator Ivocerin by the Vita Enamic hybrid ceramic, which has gained popularity as a veneering material for single-tooth treatment in recent years. Light-curing resin cements are usually preferred for their high esthetic properties and ultimate working time, with the possibility of not being fully cured under the restoration.[18] It has been reported that the recently introduced resin cements containing the novel dibenzoyl-germanium–based photoinitiator (Ivocerin) exhibit a higher DC% and higher color stability than resin cements containing camphorquinone (CQ).[22] Furthermore, a luting cement containing Ivocerin has a DC% of approximately 87%, whereas a cement containing CQ and tertiary amine has a DC% of approximately 44%.[29] It has also been reported that Ivocerin-based cement has a higher HV of approximately 47 HV, while CQ-based cement has 33 HV.[22] In this in vitro study, an attempt was made to simulate the clinical situations as far as possible. To simulate the clinical conditions for adhesive cement, where the cement is not exposed to air (except for the margins, unless an antioxidant gel is used), this study was designed to prevent polymerization inhibition by oxygen by covering the resin cement film with Mylar strips at the top and bottom similar to other studies.[30] In addition, the film thickness of the resin cement was controlled by using Mylar strips with a thickness of 50 µm as a spacer. The standardized cement thickness of 50 µm used in this study followed the recommendations of the International Organization for Standardization 4049:2019.[28] The performance of the light cure unit (LCU) in terms of irradiance and radiant exposure delivered to the sensor over a clinically relevant distance was evaluated. The mean incident irradiance of the light-curing unit used (Bluephase N LCU) was measured at 1,142 mW/cm2 with a total energy delivered of 34.47 J/cm3.

According to Flury et al,[31] the light attenuation when light-curing the light-cured resin cement through 1.5, 3.0, and 6.0 mm thick ceramic restorations was more than 80, 95, and 99%, respectively. Theoretically, the irradiance of the light-curing device should be at least 500, 2,000, and 10,000 mW/cm2, respectively, when light-curing resin cement through 1.5, 3.0, and 6.0 mm thick ceramic restorations to achieve the minimum irradiance of 100 mW/cm2 and a radiant exposure of 6 J/cm3 recommended in the previous study of Li et al,[32] and the irradiation time must be more than 60 seconds. However, the irradiance of most commercially available light-curing devices is below 2,000 mW/cm2.[31] Therefore, light-cured resin cement should not be used for ceramic restorations with a thickness more than 3.0 mm in thickness.

It is still unclear in the literature whether light-cured resin cements can be properly cured by the novel hybrid ceramics. It is also unclear to what extent of the thickness or degree of translucency of these restorations may limit their use. Since the minimum thickness at the incisal edges and functional occlusal cusps must be 1.5 mm to ensure the longevity of the restoration, which is also recommended by the manufacturer of the Vita Enamic hybrid ceramic, and based on the fact that many in vitro studies have tested the depth of cure of polymerized resin cement at ceramic thicknesses up to 5.0 mm,[2] [33] [34] it was decided to investigate the effects of different thicknesses of Vita Enamic hybrid ceramic sections of the same shade 1M1 but with two different degrees of translucency on the polymerization efficiency of light-cured resin cement.

Microhardness testing indirectly provides useful information about the effectiveness of polymerization.[27] In addition, there is a good relationship between the DC% and microhardness,[35] although the relationship is complicated because microhardness is influenced not only by the DC% but also by the extent of crosslinking.[36] The results can also be affected by inadvertently placing the microhardness indenter directly on a filler particle. Another disadvantage of using microhardness is that the measurements cannot provide quantitative information about the proportion of double bonds that have undergone polymerization. On the other hand, FTIR is the most commonly used direct method to assess the DC%. It detects the vibrational frequency of carbon bonds and identifies functional groups at the molecular level in cured and uncured samples.[37] When the sample is placed on the ATR unit, it is exposed to the infrared spectrum. Molecules start to absorb infrared light and begin to vibrate. The detector measures the absorption and transmission of infrared light within the sample, at a specific wavelength, identifying functional groups and vibration peaks.[38] In resin-based materials, aliphatic C = C bonds were identified and recorded as 1,638 cm−1 wavelength absorption peak values, while aromatic C = C double bonds were recorded as 1,609 cm−1 wavelength absorption peak values.[39] This study employed both microhardness and FTIR tests to evaluate efficacy of polymerization of light-cured resin cement.

In our study, microhardness and FTIR tests were conducted 24 hours after curing, storing the samples in the dark and under dry conditions at 37°C, as proposed by Yan et al. They concluded that significant polymerization reactions were completed within 24 hours post-mix or post-light activation for all resin cements tested.[27]

The results showed that increasing the thickness of the Vita Enamic slab affected the radiant exposure (J/cm3) received by the light-cured resin cement (Variolink Esthetic). HT Vita Enamic slabs had delivered more energy to light-cured resin cement than their LT counterparts. However, statistical significance was demonstrated only in 1.5 mm thickness of hybrid ceramic, whereas for the rest of thicknesses the differences did not reach statistical significance. The first null hypothesis was rejected, as the thickness of Vita Enamic sections had a greater effect on radiant exposure than the translucency of the same shade of Vita Enamic hybrid ceramics. Babaier et al[39] found a strong inverse linear correlation between the translucency parameter of each CAD/CAM block material included in their study, and their thickness, consistent with the results of this study. In fact, this study found that a statistical significance was only present between the 1.5 mm HT slab and its LT counterpart.

Furthermore, the results showed that increased thickness of hybrid ceramic slabs reduced the degree of translucency.

Similarly, Egilmez et al[1] reported that the thickness of material significantly affected light irradiance, which in turn affected the energy reaching the resin material, consistent with the results of this study. They also showed that Vita Enamic exhibited the lowest values of transmitted light irradiance compared with other materials.[1] Lise et al[2] estimated the minimum required energy to obtain sufficient DC% and the maximum thickness of Vita Enamic through which resin cement can be cured. Furthermore, 2.1 J/cm3 was considered the minimum radiant exposure, curing through a 1.9 mm thickness of Vita Enamic with a LCU power of 2,000 mW/cm2 in high mode. In comparison, this study found radiant exposure to be 2.444 ± 0.124 J/cm3 through a 2.5 mm thick HT slab, and 2.032 ± 0.1449 J/cm3 through a 2.5 mm thick LT slab.

The shade was standardized to 1M1 (A1), for both HT and LT Vita Enamic hybrid ceramics, and the shade of the light resin cement was standardized to neutral, as light transmission characteristics are affected by the shade of materials and thickness of cement increments.[40] A light-cured resin cement film thickness of 50 µm was standardized for all samples.

Based on microhardness test results, the second null hypothesis was partially rejected, as this study showed that the thickness of Vita Enamic slabs affected the microhardness values of the light-cured resin cement Variolink Esthetic. However, there was no statistically significant difference in the microhardness values of light-cured resin cement among different degrees of translucency when corresponding thicknesses of Vita Enamic were compared.

Babaier et al[39] tested the hardness of Variolink Esthetic cement (LC and DC) 1 hour after light polymerization under various types of ceramic and composite CAD/CAM materials of different thicknesses. They reported that the hardness of resin luting discs was significantly affected by the type of CAD/CAM material and its thickness. Greater hardness was recorded for thicknesses of 1.0 and 2.0 mm, while the lowest hardness values were recorded for the 2.5 mm thick sections.[39] These results are consistent with this study, which found that thickness plays a significant role in microhardness values.

FTIR test results suggested that the thickness of Vita Enamic sections significantly affects the DC% of resin cement, while translucency has a minor but insignificant effect on DC%. The third null hypothesis was partially rejected, as interaction of different thicknesses of Vita Enamic slabs on the DC% of the light-cured resin cement Variolink Esthetic among HT and LT groups was prominent. The minimum clinically acceptable DC% has not been precisely established in the literature. In this study, DC% ranged from 95% for the control group to 22% for the 3.0 mm thick translucent (LT) 1M1 shade Vita Enamic. The DC% varies significantly among different ceramic materials.[41] [42] Another study reported that cement polymerization depends on the shade of the restorative material,[43] where pigments in different shades can absorb light and affect polymerization.[43] However, in this study, the shade of the Vita Enamic hybrid ceramic used was standardized to 1M1 to preclude the effect of shade variation. Assessing changes in DC% during polymerization helps understand polymerization kinetics. Most post-irradiation polymerization occurs within the first few minutes or hours after light-curing, followed by a slower increase in DC% up to a maximum of 24 hours post-irradiation.[27] [44] This suggests that all light-cured resin cement films showed an increase in DC% within 24 hours, regardless of the initial DC%. Additionally, resin cement films in this study were kept covered with Mylar strips to prevent the formation of an oxygen-inhibited layer as proposed by Gauthier et al.[30] The standardized cement thickness in our study is recommended by ISO 4049:2019, although many studies and a recent systematic review reported marginal adaptation of ceramic crowns to be less than or equal to 120 µm.[45] Increasing increments of resin cement may affect the depth of cure on its bottom surface.[16] [46] Runnacles et al[46] evaluated the DC% of light-cured resin cement under different thicknesses of ceramics. They found that the DC% values of resin cements prepared under 0.5 and 1.0 mm thick ceramic samples were similar to the control group, but there was a significant reduction in DC% at thicknesses of 1.5 mm and above,[34] consistent with the results of this study. Despite the decreased DC% with increasing thickness of LT material compared with their HT counterparts, the differences did not reach statistical significance.

Barutcigil and Büyükkaplan[34] tested the DC% of RelyX light-cured and dual-cured resin cements, polymerized under varying thicknesses (0.5, 1.0, 1.5, and 2.0 mm) of Vita Enamic. They reported that despite the decreased DC% of the light-cured resin cement RelyX, as thickness increased, differences did not reach statistical significance.[34] Their results partially agree with the results of our current study.

In this study, increasing the thickness of Vita Enamic hybrid ceramic material decreased DC%. Despite the decreased DC% with increasing thickness of LT material compared with their HT counterparts, the differences did not reach statistical significance. Previous studies have reported that light-cured resin cements exhibit low DC%, especially for those prepared under ceramic restorations thicker than 1.0 mm.[47] [48] In this study, light-cured resin cement showed a reduction in DC% with increasing thickness up to 2.0 mm, likely due to the increased thickness affecting light transmission and energy reaching the resin cement. Increasing thicknesses to 2.5 and 3 mm significantly reduced the DC% compared with the control group.


#

Conclusion

Within limitations of this study, it can be concluded that:

  • Increasing the thickness of Vita Enamic hybrid ceramic sections reduced light irradiance, received radiant exposure, HV, and the DC% of the light-cured resin cement Variolink Esthetic LC of neutral shade.

  • Different translucency levels of Vita Enamic hybrid ceramic, namely translucent and highly translucent, had a small but nonsignificant effect on light irradiance, received radiant exposure, HV, and the DC% of the light-cured resin cement Variolink Esthetic LC of neutral shade.


#

Clinical Significance

Clinically, it is recommended that dual-cured resin cement be used under restorations thicker than 2.0 mm.


#

Clinical Relevance

The thickness of the Vita Enamic hybrid ceramic restoration is an important factor influencing the polymerization of the light-cured resin cement used to bond restorations and should be considered when bonding restorations.


#
#

Conflict of Interest

None declared.

  • References

  • 1 Egilmez F, Ergun G, Cekic-Nagas I, Vallittu PK, Lassila LV. Light transmission of novel CAD/CAM materials and their influence on the degree of conversion of a dual-curing resin cement. J Adhes Dent 2017; 19 (01) 39-48
  • 2 Lise DP, Van Ende A, De Munck J. et al. Light irradiance through novel CAD-CAM block materials and degree of conversion of composite cements. Dent Mater 2018; 34 (02) 296-305
  • 3 Silva LHD, Lima E, Miranda RBP, Favero SS, Lohbauer U, Cesar PF. Dental ceramics: a review of new materials and processing methods. Braz Oral Res 2017; 31 (Suppl. 01) e58
  • 4 Papadopoulos K, Pahinis K, Saltidou K, Dionysopoulos D, Tsitrou E. Evaluation of the surface characteristics of dental CAD/CAM materials after different surface treatments. Materials (Basel) 2020; 13 (04) 981
  • 5 Ruse ND, Sadoun MJ. Resin-composite blocks for dental CAD/CAM applications. J Dent Res 2014; 93 (12) 1232-1234
  • 6 Mainjot AK, Dupont NM, Oudkerk JC, Dewael TY, Sadoun MJ. From artisanal to CAD-CAM blocks: state of the art of indirect composites. J Dent Res 2016; 95 (05) 487-495
  • 7 Spitznagel FA, Boldt J, Gierthmuehlen PC. CAD/CAM ceramic restorative materials for natural teeth. J Dent Res 2018; 97 (10) 1082-1091
  • 8 Petrini M, Ferrante M, Su B. Fabrication and characterization of biomimetic ceramic/polymer composite materials for dental restoration. Dent Mater 2013; 29 (04) 375-381
  • 9 Facenda JC, Borba M, Corazza PH. A literature review on the new polymer-infiltrated ceramic-network material (PICN). J Esthet Restor Dent 2018; 30 (04) 281-286
  • 10 Aboushelib MN, Elsafi MH. Survival of resin infiltrated ceramics under influence of fatigue. Dent Mater 2016; 32 (04) 529-534
  • 11 Albero A, Pascual A, Camps I, Grau-Benitez M. Comparative characterization of a novel cad-cam polymer-infiltrated-ceramic-network. J Clin Exp Dent 2015; 7 (04) e495-e500
  • 12 Campos F, Almeida CS, Rippe MP, de Melo RM, Valandro LF, Bottino MA. Resin bonding to a hybridceramic: effects of surface treatments and aging. Oper Dent 2016; 41 (02) 171-178
  • 13 Hu M, Weiger R, Fischer J. Comparison of two test designs for evaluating the shear bond strength of resin composite cements. Dent Mater 2016; 32 (02) 223-232
  • 14 Tholey MJ, Just BA, Fischer J. Effect of surface treatment on theroughness of all-ceramic materials. Dent Mater 2015; 31: e5-e6
  • 15 Özarslan MM, Büyükkaplan UŞ, Barutcigil Ç, Arslan M, Türker N, Barutcigil K. Effects of different surface finishing procedures on the change in surface roughness and color of a polymer infiltrated ceramic network material. J Adv Prosthodont 2016; 8 (01) 16-20
  • 16 Kilinc E, Antonson SA, Hardigan PC, Kesercioglu A. The effect of ceramic restoration shade and thickness on the polymerization of light- and dual-cure resin cements. Oper Dent 2011; 36 (06) 661-669
  • 17 Meyer Jr A, Cardoso LC, Araujo E, Baratieri LN. Ceramic inlays and onlays: clinical procedures for predictable results. J Esthet Restor Dent 2003; 15 (06) 338-351 , discussion 352
  • 18 Pick B, Gonzaga CC, Junior WS, Kawano Y, Braga RR, Cardoso PE. Influence of curing light attenuation caused by aesthetic indirect restorative materials on resin cement polymerization. Eur J Dent 2010; 4 (03) 314-323
  • 19 Cadenaro M, Maravic T, Comba A. et al. The role of polymerization in adhesive dentistry. Dent Mater 2019; 35 (01) e1-e22
  • 20 Anusavice KJ, Shen C, Rawls HR. Phillips Science of Dental Materials. In: 12th ed.. Saunders; Philadelphia: 608-618 2003
  • 21 Santini A, Gallegos IT, Felix CM. Photoinitiators in dentistry: a review. Prim Dent J 2013; 2 (04) 30-33
  • 22 Kowalska A, Sokolowski J, Bociong K. The photoinitiators used in resin based dental composite-a review and future perspectives. Polymers (Basel) 2021; 13 (03) 470
  • 23 Price RB, Felix CA, Andreou P. Effects of resin composite composition and irradiation distance on the performance of curing lights. Biomaterials 2004; 25 (18) 4465-4477
  • 24 Jafarzadeh TS, Erfan M, Behroozibakhsh M. et al. Evaluation of polymerization efficacy in composite resins via FT-IR spectroscopy and vickers microhardness test. J Dent Res Dent Clin Dent Prospect 2015; 9 (04) 226-232
  • 25 Chen TA, Lu PY, Lin PY. et al. Effects of ceramic thickness, ceramic translucency, and light transmission on light-cured bulk-fill resin composites as luting cement of lithium disilicate based-ceramics. J Prosthodont Res 2024; 68 (02) 255-263
  • 26 Coldea A, Swain MV, Thiel N. Mechanical properties of polymer-infiltrated-ceramic-network materials. Dent Mater 2013; 29 (04) 419-426
  • 27 Yan YL, Kim YK, Kim KH, Kwon TY. Changes in degree of conversion and microhardness of dental resin cements. Oper Dent 2010; 35 (02) 203-210
  • 28 International Standard ISO 4049. Polymer-Based Filling, Restorative and Luting Materials. Technical Committee 106-Dentistry. International Standards Organization, Geneva, 2000
  • 29 Alkhudhairy F, Vohra F, Naseem M, Owais MM, Amer AHB, Almutairi KB. Color stability and degree of conversion of a novel dibenzoyl germanium derivative containing photo-polymerized resin luting cement. J Appl Biomater Funct Mater 2020; 18: 2280800020917326
  • 30 Gauthier MA, Stangel I, Ellis TH, Zhu XX. Oxygen inhibition in dental resins. J Dent Res 2005; 84 (08) 725-729
  • 31 Flury S, Lussi A, Hickel R, Ilie N. Light curing through glass ceramics with a second- and a third-generation LED curing unit: effect of curing mode on the degree of conversion of dual-curing resin cements. Clin Oral Investig 2013; 17 (09) 2127-2137
  • 32 Li Q, Lin H-L, Zheng M, Ozcan M, Yu H. Minimum radiant exposure and irradiance for triggering adequate polymerization of a photo-polymerized resin cement. Materials (Basel) 2021; 14 (09) 2341
  • 33 Duran İ, Kaleli N, Ural Ç, Kavut İ. Evaluation of the light transmission of chairside polymer infiltrated hybrid ceramics in different shades and thicknesses. J Appl Biomater Funct Mater 2019; 17 (01) 2280800018807109
  • 34 Barutcigil K, Büyükkaplan UŞ. The effect of thickness and translucency of polymer-infiltrated ceramic-network material on degree of conversion of resin cements. J Adv Prosthodont 2020; 12 (02) 61-66
  • 35 Leprince JG, Leveque P, Nysten B, Gallez B, Devaux J, Leloup G. New insight into the “depth of cure” of dimethacrylate-based dental composites. Dent Mater 2012; 28 (05) 512-520
  • 36 Musanje L, Darvell BW. Effects of strain rate and temperature on the mechanical properties of resin composites. Dent Mater 2004; 20 (08) 750-765
  • 37 Imazato S, McCabe JF, Tarumi H, Ehara A, Ebisu S. Degree of conversion of composites measured by DTA and FTIR. Dent Mater 2001; 17 (02) 178-183
  • 38 Yoon TH, Lee YK, Lim BS, Kim CW. Degree of polymerization of resin composites by different light sources. J Oral Rehabil 2002; 29 (12) 1165-1173
  • 39 Babaier R, Haider J, Silikas N, Watts DC. Effect of CAD/CAM aesthetic material thickness and translucency on the polymerisation of light- and dual-cured resin cements. Dent Mater 2022; 38 (12) 2073-2083
  • 40 Sulaiman TA, Abdulmajeed AA, Donovan TE. et al. Degree of conversion of dual-polymerizing cements light polymerized through monolithic zirconia of different thicknesses and types. J Prosthet Dent 2015; 114 (01) 103-108
  • 41 Lopes Cde CA, Rodrigues RB, Silva AL, Simamoto Júnior PC, Soares CJ, Novais VR. Degree of conversion and mechanical properties of resin cements cured through different all-ceramic systems. Braz Dent J 2015; 26 (05) 484-489
  • 42 Peixoto RT, Paulinelli VM, Sander HH, Lanza MD, Cury LA, Poletto LT. Light transmission through porcelain. Dent Mater 2007; 23 (11) 1363-1368
  • 43 Pilo R, Cardash HS. Post-irradiation polymerization of different anterior and posterior visible light-activated resin composites. Dent Mater 1992; 8 (05) 299-304
  • 44 Contrepois M, Soenen A, Bartala M, Laviole O. Marginal adaptation of ceramic crowns: a systematic review. J Prosthet Dent 2013; 110 (06) 447-454.e10
  • 45 Calgaro PAM, Furuse AY, Correr GM, Ornaghi BP, Gonzaga CC. Influence of the interposition of ceramic spacers on the degree of conversion and the hardness of resin cements. Braz Oral Res 2013; 27 (05) 403-409
  • 46 Runnacles P, Correr GM, Baratto Filho F, Gonzaga CC, Furuse AY. Degree of conversion of a resin cement light-cured through ceramic veneers of different thicknesses and types. Braz Dent J 2014; 25 (01) 38-42
  • 47 Cho SH, Lopez A, Berzins DW, Prasad S, Ahn KW. Effect of different thicknesses of pressable ceramic veneers on polymerization of light-cured and dual-cured resin cements. J Contemp Dent Pract 2015; 16 (05) 347-352
  • 48 Novais VR, Raposo LH, Miranda RR, Lopes CC, Simamoto PC, Soares CJ. Degree of conversion and bond strength of resin-cements to feldspathic ceramic using different curing modes. J Appl Oral Sci 2017; 25 (01) 61-68

Address for correspondence

Esraa Jaber, MSc Restorative Dentistry (MSRD), MFDS RCSI, DDS
College of Dentistry, Ajman University, Ajman
P.O. Box 346
United Arab Emirates   

Publication History

Article published online:
17 June 2025

© 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/)

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

  • References

  • 1 Egilmez F, Ergun G, Cekic-Nagas I, Vallittu PK, Lassila LV. Light transmission of novel CAD/CAM materials and their influence on the degree of conversion of a dual-curing resin cement. J Adhes Dent 2017; 19 (01) 39-48
  • 2 Lise DP, Van Ende A, De Munck J. et al. Light irradiance through novel CAD-CAM block materials and degree of conversion of composite cements. Dent Mater 2018; 34 (02) 296-305
  • 3 Silva LHD, Lima E, Miranda RBP, Favero SS, Lohbauer U, Cesar PF. Dental ceramics: a review of new materials and processing methods. Braz Oral Res 2017; 31 (Suppl. 01) e58
  • 4 Papadopoulos K, Pahinis K, Saltidou K, Dionysopoulos D, Tsitrou E. Evaluation of the surface characteristics of dental CAD/CAM materials after different surface treatments. Materials (Basel) 2020; 13 (04) 981
  • 5 Ruse ND, Sadoun MJ. Resin-composite blocks for dental CAD/CAM applications. J Dent Res 2014; 93 (12) 1232-1234
  • 6 Mainjot AK, Dupont NM, Oudkerk JC, Dewael TY, Sadoun MJ. From artisanal to CAD-CAM blocks: state of the art of indirect composites. J Dent Res 2016; 95 (05) 487-495
  • 7 Spitznagel FA, Boldt J, Gierthmuehlen PC. CAD/CAM ceramic restorative materials for natural teeth. J Dent Res 2018; 97 (10) 1082-1091
  • 8 Petrini M, Ferrante M, Su B. Fabrication and characterization of biomimetic ceramic/polymer composite materials for dental restoration. Dent Mater 2013; 29 (04) 375-381
  • 9 Facenda JC, Borba M, Corazza PH. A literature review on the new polymer-infiltrated ceramic-network material (PICN). J Esthet Restor Dent 2018; 30 (04) 281-286
  • 10 Aboushelib MN, Elsafi MH. Survival of resin infiltrated ceramics under influence of fatigue. Dent Mater 2016; 32 (04) 529-534
  • 11 Albero A, Pascual A, Camps I, Grau-Benitez M. Comparative characterization of a novel cad-cam polymer-infiltrated-ceramic-network. J Clin Exp Dent 2015; 7 (04) e495-e500
  • 12 Campos F, Almeida CS, Rippe MP, de Melo RM, Valandro LF, Bottino MA. Resin bonding to a hybridceramic: effects of surface treatments and aging. Oper Dent 2016; 41 (02) 171-178
  • 13 Hu M, Weiger R, Fischer J. Comparison of two test designs for evaluating the shear bond strength of resin composite cements. Dent Mater 2016; 32 (02) 223-232
  • 14 Tholey MJ, Just BA, Fischer J. Effect of surface treatment on theroughness of all-ceramic materials. Dent Mater 2015; 31: e5-e6
  • 15 Özarslan MM, Büyükkaplan UŞ, Barutcigil Ç, Arslan M, Türker N, Barutcigil K. Effects of different surface finishing procedures on the change in surface roughness and color of a polymer infiltrated ceramic network material. J Adv Prosthodont 2016; 8 (01) 16-20
  • 16 Kilinc E, Antonson SA, Hardigan PC, Kesercioglu A. The effect of ceramic restoration shade and thickness on the polymerization of light- and dual-cure resin cements. Oper Dent 2011; 36 (06) 661-669
  • 17 Meyer Jr A, Cardoso LC, Araujo E, Baratieri LN. Ceramic inlays and onlays: clinical procedures for predictable results. J Esthet Restor Dent 2003; 15 (06) 338-351 , discussion 352
  • 18 Pick B, Gonzaga CC, Junior WS, Kawano Y, Braga RR, Cardoso PE. Influence of curing light attenuation caused by aesthetic indirect restorative materials on resin cement polymerization. Eur J Dent 2010; 4 (03) 314-323
  • 19 Cadenaro M, Maravic T, Comba A. et al. The role of polymerization in adhesive dentistry. Dent Mater 2019; 35 (01) e1-e22
  • 20 Anusavice KJ, Shen C, Rawls HR. Phillips Science of Dental Materials. In: 12th ed.. Saunders; Philadelphia: 608-618 2003
  • 21 Santini A, Gallegos IT, Felix CM. Photoinitiators in dentistry: a review. Prim Dent J 2013; 2 (04) 30-33
  • 22 Kowalska A, Sokolowski J, Bociong K. The photoinitiators used in resin based dental composite-a review and future perspectives. Polymers (Basel) 2021; 13 (03) 470
  • 23 Price RB, Felix CA, Andreou P. Effects of resin composite composition and irradiation distance on the performance of curing lights. Biomaterials 2004; 25 (18) 4465-4477
  • 24 Jafarzadeh TS, Erfan M, Behroozibakhsh M. et al. Evaluation of polymerization efficacy in composite resins via FT-IR spectroscopy and vickers microhardness test. J Dent Res Dent Clin Dent Prospect 2015; 9 (04) 226-232
  • 25 Chen TA, Lu PY, Lin PY. et al. Effects of ceramic thickness, ceramic translucency, and light transmission on light-cured bulk-fill resin composites as luting cement of lithium disilicate based-ceramics. J Prosthodont Res 2024; 68 (02) 255-263
  • 26 Coldea A, Swain MV, Thiel N. Mechanical properties of polymer-infiltrated-ceramic-network materials. Dent Mater 2013; 29 (04) 419-426
  • 27 Yan YL, Kim YK, Kim KH, Kwon TY. Changes in degree of conversion and microhardness of dental resin cements. Oper Dent 2010; 35 (02) 203-210
  • 28 International Standard ISO 4049. Polymer-Based Filling, Restorative and Luting Materials. Technical Committee 106-Dentistry. International Standards Organization, Geneva, 2000
  • 29 Alkhudhairy F, Vohra F, Naseem M, Owais MM, Amer AHB, Almutairi KB. Color stability and degree of conversion of a novel dibenzoyl germanium derivative containing photo-polymerized resin luting cement. J Appl Biomater Funct Mater 2020; 18: 2280800020917326
  • 30 Gauthier MA, Stangel I, Ellis TH, Zhu XX. Oxygen inhibition in dental resins. J Dent Res 2005; 84 (08) 725-729
  • 31 Flury S, Lussi A, Hickel R, Ilie N. Light curing through glass ceramics with a second- and a third-generation LED curing unit: effect of curing mode on the degree of conversion of dual-curing resin cements. Clin Oral Investig 2013; 17 (09) 2127-2137
  • 32 Li Q, Lin H-L, Zheng M, Ozcan M, Yu H. Minimum radiant exposure and irradiance for triggering adequate polymerization of a photo-polymerized resin cement. Materials (Basel) 2021; 14 (09) 2341
  • 33 Duran İ, Kaleli N, Ural Ç, Kavut İ. Evaluation of the light transmission of chairside polymer infiltrated hybrid ceramics in different shades and thicknesses. J Appl Biomater Funct Mater 2019; 17 (01) 2280800018807109
  • 34 Barutcigil K, Büyükkaplan UŞ. The effect of thickness and translucency of polymer-infiltrated ceramic-network material on degree of conversion of resin cements. J Adv Prosthodont 2020; 12 (02) 61-66
  • 35 Leprince JG, Leveque P, Nysten B, Gallez B, Devaux J, Leloup G. New insight into the “depth of cure” of dimethacrylate-based dental composites. Dent Mater 2012; 28 (05) 512-520
  • 36 Musanje L, Darvell BW. Effects of strain rate and temperature on the mechanical properties of resin composites. Dent Mater 2004; 20 (08) 750-765
  • 37 Imazato S, McCabe JF, Tarumi H, Ehara A, Ebisu S. Degree of conversion of composites measured by DTA and FTIR. Dent Mater 2001; 17 (02) 178-183
  • 38 Yoon TH, Lee YK, Lim BS, Kim CW. Degree of polymerization of resin composites by different light sources. J Oral Rehabil 2002; 29 (12) 1165-1173
  • 39 Babaier R, Haider J, Silikas N, Watts DC. Effect of CAD/CAM aesthetic material thickness and translucency on the polymerisation of light- and dual-cured resin cements. Dent Mater 2022; 38 (12) 2073-2083
  • 40 Sulaiman TA, Abdulmajeed AA, Donovan TE. et al. Degree of conversion of dual-polymerizing cements light polymerized through monolithic zirconia of different thicknesses and types. J Prosthet Dent 2015; 114 (01) 103-108
  • 41 Lopes Cde CA, Rodrigues RB, Silva AL, Simamoto Júnior PC, Soares CJ, Novais VR. Degree of conversion and mechanical properties of resin cements cured through different all-ceramic systems. Braz Dent J 2015; 26 (05) 484-489
  • 42 Peixoto RT, Paulinelli VM, Sander HH, Lanza MD, Cury LA, Poletto LT. Light transmission through porcelain. Dent Mater 2007; 23 (11) 1363-1368
  • 43 Pilo R, Cardash HS. Post-irradiation polymerization of different anterior and posterior visible light-activated resin composites. Dent Mater 1992; 8 (05) 299-304
  • 44 Contrepois M, Soenen A, Bartala M, Laviole O. Marginal adaptation of ceramic crowns: a systematic review. J Prosthet Dent 2013; 110 (06) 447-454.e10
  • 45 Calgaro PAM, Furuse AY, Correr GM, Ornaghi BP, Gonzaga CC. Influence of the interposition of ceramic spacers on the degree of conversion and the hardness of resin cements. Braz Oral Res 2013; 27 (05) 403-409
  • 46 Runnacles P, Correr GM, Baratto Filho F, Gonzaga CC, Furuse AY. Degree of conversion of a resin cement light-cured through ceramic veneers of different thicknesses and types. Braz Dent J 2014; 25 (01) 38-42
  • 47 Cho SH, Lopez A, Berzins DW, Prasad S, Ahn KW. Effect of different thicknesses of pressable ceramic veneers on polymerization of light-cured and dual-cured resin cements. J Contemp Dent Pract 2015; 16 (05) 347-352
  • 48 Novais VR, Raposo LH, Miranda RR, Lopes CC, Simamoto PC, Soares CJ. Degree of conversion and bond strength of resin-cements to feldspathic ceramic using different curing modes. J Appl Oral Sci 2017; 25 (01) 61-68

Zoom Image
Fig. 1 Study design. The figure shows number of hybrid ceramic slabs, number of resin cement films in each group, and tests applied.
Zoom Image
Fig. 2 The figure shows the subjects needed to conduct the current study. (A) Details of sample size calculations.
Zoom Image
Fig. 3 The hybrid ceramic slabs' thicknesses (± 0.01) checked by using Digital Caliper (INSIZE Co., LTD) (A); desired 1 mm thickness of hybrid ceramic measured with digital caliper (B); desired 2 mm thickness of hybrid ceramic measured with digital caliper (C); desired 3 mm thickness of hybrid ceramic measured with digital caliper (D); 3 mm thickness slab of hybrid ceramic ascertained using laser scan micrometer (LSM-503s, Mitutoyo America Corporation) (E).
Zoom Image
Fig. 4 Graph demonstrates the irradiance (mW/cm2) delivered to the sensor on the MARC during the time period of light exposure.
Zoom Image
Fig. 5 Graph demonstrates the irradiance (mW/cm2) delivered to the sensor through all samples of different thicknesses and translucencies on the MARC during the time period of light exposure.
Zoom Image
Fig. 6 Boxplots of radiant exposure data (in J/cm3) of 50-micron thickness light-cured resin cement polymerized without interposition of hybrid ceramic slab (control), and light-cured resin cement polymerized under 1.0, 1.5, 2.0, 2.5, and 3.0 mm of hybrid ceramic slab of translucent (LT) and highly translucent (HT) types.
Zoom Image
Fig. 7 Boxplots of microhardness value (HV) of 50-micron thickness light-cured resin cement polymerized without interposition of hybrid ceramic slab (control), and light-cured resin cement polymerized under 1.0, 1.5, 2.0, 2.5, and 3.0 mm of hybrid ceramic slab of translucent and highly translucent types.
Zoom Image
Fig. 8 Boxplots of degree of conversion percentage (%DC) of 50-micron thickness light-cured resin cement polymerized without interposition of hybrid ceramic slab (control), and light-cured resin cement polymerized under 1.0, 1.5, 2.0, 2.5, and 3.0 mm of hybrid ceramic slabs of translucent and highly translucent types.