J Wrist Surg 2022; 11(05): 406-415
DOI: 10.1055/s-0041-1740486
Scientific Article

Normal Values of Distal Radioulnar Joint Kinematics during a Dynamic Press Test

1   Department of Orthopaedics, University Clinic for Hand, Hip and Knee Surgery, Hospital Unit West, Holstebro, Denmark
2   Department of Clinical Medicine, Aarhus University, Aarhus N, Denmark
3   AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus N, Denmark
,
Sepp De Raedt
3   AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus N, Denmark
4   NRT X-RAY A/S, Hasselager, Denmark
,
Emil Toft Petersen
1   Department of Orthopaedics, University Clinic for Hand, Hip and Knee Surgery, Hospital Unit West, Holstebro, Denmark
2   Department of Clinical Medicine, Aarhus University, Aarhus N, Denmark
3   AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus N, Denmark
,
Katriina Bøcker Puhakka
5   Department of Radiology, Aarhus University Hospital, Aarhus N, Denmark
6   Department of Radiology, Regional Hospital Horsens, Horsens, Denmark
,
Torben Bæk Hansen
1   Department of Orthopaedics, University Clinic for Hand, Hip and Knee Surgery, Hospital Unit West, Holstebro, Denmark
2   Department of Clinical Medicine, Aarhus University, Aarhus N, Denmark
,
Maiken Stilling
2   Department of Clinical Medicine, Aarhus University, Aarhus N, Denmark
3   AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus N, Denmark
7   Department of Orthopaedic Surgery, Aarhus University, Aarhus N, Denmark
› Author Affiliations
Funding This research has received grants from Health Research Fund of Central Denmark Region, Aarhus University, The Danish Rheumatism Association and Innovation Fund Denmark (Grant 69-2013-1). All funding sources did not play a role in the study investigation.

Abstract

Background Measurement of in vivo distal radioulnar joint (DRUJ) pathomechanics during simple activities can represent the disability experienced by patients and may be useful in diagnostics of DRUJ instability. A first step is to describe the physiological normal limits for DRUJ kinematics in a reproducible and precise test setup, which was the aim of this study.

Methods DRUJ kinematics were evaluated in 33 participants with dynamic radiostereometry (RSA) while performing a standardized press test examination. AutoRSA software was used for image analyses. Computed tomography (CT) forearm bone models were generated, and standardized anatomical axes were applied to estimate kinematic outcomes including, DRUJ translation, DRUJ position ratio, and changes in ulnar variance. Repeatability of dynamic RSA press test double examinations was evaluated to estimate the precision and intraclass correlation coefficient (ICC) test–retest agreement.

Results The maximum force during the press test was 6.0 kg (95% confidence interval [CI]: 5.1–6.9), which resulted in 4.7 mm (95% CI: 4.2–5.1) DRUJ translation, DRUJ position ratio of 0.40 (95% CI: 0.33–0.44), and increase in ulnar variance of 1.1 mm (95% CI: 1.0–1.2). The mean maximum DRUJ translation leveled off after a 5 kg force application. The DRUJ translation ICC coefficient was 0.93 within a prediction interval of ± 0.53mm.

Conclusions This clinical study demonstrates the normal values of DRUJ kinematics and reports excellent agreement and high precision of the press tests examination using an automated noninvasive dynamic RSA imaging method based on patient-specific CT bone models. The next step is the application of the method in patients with arthroscopic verified triangular fibrocartilage complex injuries.

Level of Evidence This is a Level IV, case series study.

Note

The institutions at Which the work was performed were Department of Orthopaedics, University Clinic for Hand, Hip and Knee Surgery, Hospital Unit West, Lægaardvej 12, 7500 Holstebro, Denmark and Department of Orthopaedic Surgery, Aarhus University, Palle Juul-Jensens Boulevard 165, 8200 Aarhus N, Denmark


Ethical Approval

The Danish Data Protection Agency (Journal no.2012–58–006; issued May 2016) and The Central Denmark Region Committees on Health Research Ethics (Journal no.1–10–72–146–16; issued August 2016) approved the study. Informed consent was obtained from the participating subjects.




Publication History

Received: 02 June 2021

Accepted: 09 November 2021

Article published online:
27 December 2021

© 2021. Thieme. All rights reserved.

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

 
  • References

  • 1 Nagata H, Hosny S, Giddins GE. In-vivo measurement of distal radio-ulnar joint translation. Hand Surg 2013; 18 (01) 15-20
  • 2 Pickering GT, Nagata H, Giddins GEB. In-vivo three-dimensional measurement of distal radioulnar joint translation in normal and clinically unstable populations. J Hand Surg Eur Vol 2016; 41 (05) 521-526
  • 3 Wijffels M, Stomp W, Krijnen P, Reijnierse M, Schipper I. Computed tomography for the detection of distal radioulnar joint instability: normal variation and reliability of four CT scoring systems in 46 patients. Skeletal Radiol 2016; 45 (11) 1487-1493
  • 4 Schnetzke M, Porschke F, Hoppe K, Studier-Fischer S, Gruetzner PA, Guehring T. Outcome of early and late diagnosed Essex-Lopresti Injury. J Bone Joint Surg Am 2017; 99 (12) 1043-1050
  • 5 Park MJ, Kim JP. Reliability and normal values of various computed tomography methods for quantifying distal radioulnar joint translation. J Bone Joint Surg Am 2008; 90 (01) 145-153
  • 6 Lo IK, MacDermid JC, Bennett JD, Bogoch E, King GJ. The radioulnar ratio: a new method of quantifying distal radioulnar joint subluxation. J Hand Surg Am 2001; 26 (02) 236-243
  • 7 King GJ, McMurtry RY, Rubenstein JD, Gertzbein SD. Kinematics of the distal radioulnar joint. J Hand Surg Am 1986; 11 (06) 798-804
  • 8 Hess F, Farshad M, Sutter R, Nagy L, Schweizer A. A novel technique for detecting instability of the distal radioulnar joint in complete triangular fibrocartilage complex lesions. J Wrist Surg 2012; 1 (02) 153-158
  • 9 Thillemann JK, De Raedt S, Jørgensen PB, Rømer L, Hansen TB, Stilling M. Distal radioulnar joint stability measured with radiostereometry during the piano key test. J Hand Surg Eur Vol 2020; 45 (09) 923-930
  • 10 Christensen R, Petersen ET, Jürgens-Lahnstein J. et al. Assessment of knee kinematics with dynamic radiostereometry: validation of an automated model-based method of analysis using bone models. J Orthop Res 2021; 39 (03) 597-608
  • 11 Atzei A, Rizzo A, Luchetti R, Fairplay T. Arthroscopic foveal repair of triangular fibrocartilage complex peripheral lesion with distal radioulnar joint instability. Tech Hand Up Extrem Surg 2008; 12 (04) 226-235
  • 12 McDonald CP, Moutzouros V, Bey MJ. Measuring dynamic in-vivo elbow kinematics: description of technique and estimation of accuracy. J Biomech Eng 2012; 134 (12) 124502
  • 13 Hagert CG. The distal radioulnar joint in relation to the whole forearm. Clin Orthop Relat Res 1992; (275) 56-64
  • 14 Kaptein BL, Valstar ER, Stoel BC, Rozing PM, Reiber JHC. Evaluation of three pose estimation algorithms for model-based roentgen stereophotogrammetric analysis. Proc Inst Mech Eng H 2004; 218 (4, H4): 231-238
  • 15 Hansen L, De Raedt S, Jørgensen PB, Mygind-Klavsen B, Kaptein B, Stilling M. Marker free model-based radiostereometric analysis for evaluation of hip joint kinematics: A validation study. Bone Joint Res 2018; 7 (06) 379-387
  • 16 Hemmingsen CK, Thillemann TM, Elmengaard B. et al. Elbow biomechanics, radiocapitellar joint pressure, and interosseous membrane strain before and after radial head arthroplasty. J Orthop Res 2020; 38 (03) 510-522
  • 17 Chen YR, Tang JB. In vivo gliding and contact characteristics of the sigmoid notch and the ulna in forearm rotation. J Hand Surg Am 2013; 38 (08) 1513-1519
  • 18 Xu J, Tang JB. In vivo changes in lengths of the ligaments stabilizing the distal radioulnar joint. J Hand Surg Am 2009; 34 (01) 40-45
  • 19 af Ekenstam F, Hagert CG. Anatomical studies on the geometry and stability of the distal radio ulnar joint. Scand J Plast Reconstr Surg 1985; 19 (01) 17-25
  • 20 Hojo J, Omokawa S, Iida A, Ono H, Moritomo H, Tanaka Y. Three-dimensional kinematic analysis of the distal radioulnar joint in the axial-loaded extended wrist position. J Hand Surg Am 2019; 44 (04) 336.e1-336.e6 , e336
  • 21 Ozer K, Zhu AF, Siljander B, Lawton JN, Waljee JF. The Effect of Axial Loading on Ulnar Variance. J Wrist Surg 2018; 7 (03) 247-252
  • 22 Friedman SL, Palmer AK, Short WH, Levinsohn EM, Halperin LS. The change in ulnar variance with grip. J Hand Surg Am 1993; 18 (04) 713-716
  • 23 Thillemann JK, De Raedt S, Hansen TB, Munk B, Stilling M. Distal radioulnar joint stabilization with open foveal reinsertion versus tendon graft reconstruction: an experimental study using radiostereometry. J Exp Orthop 2021; 8 (01) 10