Subscribe to RSS
DOI: 10.1055/s-0040-1716430
A Novel Technique in Fibrin Gluing of Intercostal Nerves: Splint and Weld
Abstract
Splint and weld technique ensures a sound coaptation of intercostal and musculocutaneous nerves with minimal introduction of synthetic suture through the neural tissue.
#
Introduction
Traditionally, nerve coaptation has been achieved by way of suturing. Challenges encountered during this procedure in the form of an uneven tension, skewed alignment, trauma to nerve fascicles from microinstruments, and foreign body reaction to synthetic suture, often lead to loss of regenerative axons with resultant suboptimal functional outcomes. Recent trends of using fibrin glue in nerve repair can yield results akin to suturing in experienced hands, and has the potential of being superior when the surgeon is less conversant with microsurgical techniques.[1] Fibrin glue creates an adhesive cylinder around the stumps of the nerve through which regenerating axons grow by chemotaxis.[2]
The new technique described here takes advantages of both suture and glue fixation without introducing foreign material through the actual neural tissue and at the same time ensuring a sound coaptation.
Description of Technique
Distal 2.5 cm segments of three intercostal nerves are placed parallel on a thin plastic sheet ([Fig. 1]) and splinted with a layer of fibrin glue ([Fig. 2]). Approximately 60 seconds later, on formation of a coagulum, the glued edge of intercostal nerves is freshened with sharp microscissors. Thereafter, three 10/0 nylon sutures are passed through the edges of coagulum and the epineurium of the musculocutaneous nerve at 3, 6 and 12 o’ clock positions ([Fig. 3]). Placement of microsutures through the soft and fragile coagulum requires a gentle and careful handling. A tension-free approximation is ensured without buckling of fascicles. Finally, the site of coaptation is welded with a layer of fibrin glue ([Fig. 4]). [Fig. 5] depicts a line diagram illustration of the technique. In the entire process, approximately 2 mL of reconstituted fibrin glue is consumed.
#
#
Discussion
Synthetic microsutures have traditionally been used in nerve coaptation. However, being foreign, material sutures are known to produce local inflammatory reaction that might hamper regeneration.[1] These pathologic processes cause hindrance to the sprouting axons and impair blood supply to the fascicles. Suturing of thin caliber nerves, for example, intercostal nerves, may also be difficult and technically challenging. Use of fibrin glue obviates suture-related problems. Fibrin glue forms an adhesive cylinder around the nerve ends and allows axonal migration by chemotaxis.[2] [3]
Intercostal nerve to musculocutaneous nerve neurotization is a standard procedure in restoration of elbow flexion. Usually, three intercostal nerves are coapted to musculocutaneous nerve using nylon suture or fibrin glue. Being thin and fragile, each intercostal nerve does not allow placement of more than a single suture. Suturing itself causes microtrauma and inflammatory reaction, even with sutures as thin as 10/0, apart from the possibility of mismatch between sensory and motor fascicles. These problems are obviated with fibrin glue fixation,[4] [5] although the strength at coaptation site with glue fixation alone remains the subject of concern. Suture and weld technique take advantages of both suture and glue fixation, without introducing foreign material through the actual neural tissue and at the same time ensuring a sound coaptation. This technique has been used in adult (six patients) as well as birth-related (11 patients) brachial plexus palsy patients. In the adult group, three patients restored M3, two patients M2, and a single patient M1 elbow flexion at 14 months follow-up. Results have been more encouraging in the birth palsy group, with nine patients attaining M3, and two patients M2 at 10 months follow-up. When compared with conventional techniques, the functional gains in attainment of active elbow flexion have been superior with splint and weld technique.
#
Conclusion
This technique has dual advantage of both suturing as well as glue coaptation. Placement of sutures in extraneural tissue minimizes foreign body reaction, while splinting of distal segments of intercostal nerves ensures good approximation without loss of axons from misdirected fascicles.
#
#
Conflicts of interest
None declared.
Acknowledgment
Dr. Amborish Nath for line diagram illustration.
-
References
- 1 Suri A, Mehta VS, Sarkar C. Microneural anastomosis with fibrin glue: an experimental study. Neurol India 2002; 50 (01) 23-26
- 2 Narakas A. The use of fibrin glue in repair of peripheral nerves. Orthop Clin North Am 1988; 19 (01) 187-199
- 3 Palazzi S, Vila-Torres J, Lorenzo JC. Fibrin glue is a sealant and not a nerve barrier. J Reconstr Microsurg 1995; 11 (02) 135-139
- 4 Menovsky T, Bartels RH. Stabilization and accurate trimming of nerve ends: practical use of fibrin glue: technical note. Neurosurgery 1999; 44 (01) 224-225, discussion 225–226
- 5 Bhandari PS. Use of fibrin glue in the repair of brachial plexus and peripheral nerve injuries. Ind J Neurotruma. 2013; 10: 30-32
Address for correspondence
Publication History
Article published online:
29 August 2020
© .
Thieme Medical and Scientific Publishers Private Ltd.
A-12, Second Floor, Sector -2, NOIDA -201301, India
-
References
- 1 Suri A, Mehta VS, Sarkar C. Microneural anastomosis with fibrin glue: an experimental study. Neurol India 2002; 50 (01) 23-26
- 2 Narakas A. The use of fibrin glue in repair of peripheral nerves. Orthop Clin North Am 1988; 19 (01) 187-199
- 3 Palazzi S, Vila-Torres J, Lorenzo JC. Fibrin glue is a sealant and not a nerve barrier. J Reconstr Microsurg 1995; 11 (02) 135-139
- 4 Menovsky T, Bartels RH. Stabilization and accurate trimming of nerve ends: practical use of fibrin glue: technical note. Neurosurgery 1999; 44 (01) 224-225, discussion 225–226
- 5 Bhandari PS. Use of fibrin glue in the repair of brachial plexus and peripheral nerve injuries. Ind J Neurotruma. 2013; 10: 30-32