Thromb Haemost 2005; 93(05): 1007-1009
DOI: 10.1055/s-0037-1616577
Letters to the Editor
Schattauer GmbH

The Activated Seven Lupus Anticoagulant (ASLA) test has comparable sensitivity to classical assays for screening of lupus anticoagulant

Marta Martinuzzo
1   Department of Haematology, Thrombosis and Haemostasis, Favaloro University and Institute of Cardiology and Cardiovascular Surgery, Favaloro Foundation, Buenos Aires, Argentina
,
Yolanda Adamczuk
1   Department of Haematology, Thrombosis and Haemostasis, Favaloro University and Institute of Cardiology and Cardiovascular Surgery, Favaloro Foundation, Buenos Aires, Argentina
,
Maria Luisa Iglesias Varela
1   Department of Haematology, Thrombosis and Haemostasis, Favaloro University and Institute of Cardiology and Cardiovascular Surgery, Favaloro Foundation, Buenos Aires, Argentina
,
Gonzalo Pombo
1   Department of Haematology, Thrombosis and Haemostasis, Favaloro University and Institute of Cardiology and Cardiovascular Surgery, Favaloro Foundation, Buenos Aires, Argentina
,
Forastiero Ricardo
1   Department of Haematology, Thrombosis and Haemostasis, Favaloro University and Institute of Cardiology and Cardiovascular Surgery, Favaloro Foundation, Buenos Aires, Argentina
› Author Affiliations
Further Information

Publication History

Received 25 August 2004

Accepted after 09 February 2005

Publication Date:
15 December 2017 (online)

 

 
  • References

  • 1 Wilson W, Gharavi A, Koike T. et al. International consensus statement on preliminary classification criteria for definite antiphospholipid syndrome. Report of an International Workshop. Arthritis Rheum 1999; 42: 1309-11.
  • 2 Brandt JT, Triplett DA, Alving B. et al. Criteria for the diagnosis of lupus anticoagulant: an update. Thromb Haemost 1995; 74: 1185-90.
  • 3 Moore GW, Smith MP, Patel Y. et al. The activated seven lupus anticoagulant (ASLA) assay: a new test for lupus anticoagulants (LAs). Evidence that some LAs are detectable only in extrinsic pathway-based assays. Blood Coagul Fibrinolysis 2002; 13: 261-9.
  • 4 Rosner E, Pauzner R, Lusky A. et al. Detection and quantitative evaluation of lupus circulating anticoagulant activity. Thromb Haemost 1987; 57: 144-7.
  • 5 Lawrie AS, Mackie IJ, Purdy G, Machin SJ. The sensitivity and specificity of commercial reagents for the detection of lupus anticoagulant show marked differences in performance between photo-optical and mechanical coagulometers. Thromb Haemost 1999; 81: 758-62.
  • 6 Arnout J, Vanrusselt M, Huybrechts E. et al. Optimization of the dilute prothrombin time for the detection of lupus anticoagulant by use of a recombinant tissue thromboplastin. Br J Haematol 1994; 87: 94-9.
  • 7 Forastiero RR, Cerrato GS, Carreras LO. Evaluation of recently described tests for detection of the lupus anticoagulant. Thromb Haemost 1994; 72: 728-3.