Keywords
congenital heart disease - heart valve disease - pulmonary valve
Introduction
Double-chambered right ventricle (DCRV) is a rare anomaly with tissue dividing the
right ventricle (RV). The division can be caused by hypertrophied or anomalous muscle
or aberrant moderator band, resulting in intraventricular pressure gradients. Many
congenital heart defects can be associated with DCRV such as ventricular septal defect,
tetralogy of Fallot, or Ebstein anomaly.[1] We describe a patient who presented with DCRV 40 years after surgical pulmonary
valvuloplasty.
Case Description
A 47-year-old woman (size 158 cm; weight 68 kg) with a history of surgical pulmonary
valvuloplasty 40 years ago in Turkey was admitted with progressive chest pain and
exercise intolerance. Documentation of the initial procedure was scarce; therefore,
no further information about the former presence of a ventricular septal defect (VSD)
was provided. Coronary artery disease was excluded. Recurrent pulmonary stenosis plus
an additional subvalvular obstruction of the RV was revealed by echocardiography.
Maximal gradients through the intraventricular stenosis and the pulmonary valve were
77 and 84 mm Hg, respectively, with a maximal Doppler flow velocity of 4.6 m/s. Pulmonary
valve diameter was 20 mm evaluated by echocardiography, resulting in a z-score of
−2 (adjusted for sex and body surface area) with a diameter of the aortic valve of
22 mm. Right heart catheterization showed suprasystemic RV pressure of 163/5 mm Hg.
Subvalvular pulmonary stenosis was confirmed by angiography and magnetic resonance
imaging (MRI).
For the operative procedure, cardiopulmonary bypass was instituted via peripheral
vessels. An additional venous cannula was inserted via the superior vena cava for
unloading of the RV. After administration of cardioplegia, the infundibulum of the
RV was opened in cardiac arrest revealing two bulging muscle rings covered with scar
tissue obstructing the subvalvular outflow tract. The fibrous scar was removed and
the hypertrophied moderator band was transected. Inspection of the pulmonary valve
showed a continuation of the fibrous tissue into the valvular apparatus with thickening
and fusion of the leaflets without possibility for a reconstructive approach. The
incision was therefore extended across the annulus of the pulmonary valve into the
main pulmonary artery. The thickened leaflets of the valve were removed in total and
a Carpentier-Edwards PERIMOUNT (Edwards Lifesciences, Irvine, California, United States)
aortic pericardial bioprosthesis (23 mm, model 2900) was inserted using Teflon-reinforced
U-stitches with the pulmonary annulus covering about two-thirds of the prosthesis
([Fig. 1]). An Auto Tissue Matrix Patch (Auto Tissue GmbH, Berlin, Germany) was then used
for enlargement of the main pulmonary artery and for covering the remaining one-third
of the prosthesis and the RV ([Fig. 2]). The patient was then weaned from cardiopulmonary bypass.
Fig. 1 Surgical view on the right ventricular outflow tract with incision of the right ventricle
across the annulus of the pulmonary valve into the main pulmonary artery. The bioprosthesis
is inserted with the pulmonary annulus covering about two-thirds the prosthesis. The
patch is attached to the ventricular end of the incision.
Fig. 2 Surgical view on the right ventricular outflow. The patch covers the ventricular
incision and about one-third of the bioprosthesis simultaneously enlarging the main
pulmonary artery.
The following clinical course was uneventful. The patient was extubated within 9 hours
and transported to the normal ward after 4 days. Routine echocardiographic follow-up
revealed a no gradient across the prosthesis and no valvular regurgitation with a
maximal pressure gradient of 12 mm Hg and a Doppler velocity of 170 cm/s.
Discussion
The patient was operated for DCRV 40 years after surgical pulmonary valvuloplasty.
Because DCRV is typically considered to be a congenital heart disorder, this might
have been misdiagnosed in childhood or become more prominent in the following decades
as investigated by Oliver et al in a series of patients showing a fast progression
of midventricular obstruction in adolescents and young adults with DCRV.[2] As exact information about the initial procedure performed in Turkey 1974 was not
available, the former presence of a VSD was unknown at the time of admission. However,
there was no intraoperative evidence about a past surgical VSD closure.
In the presented case, the sequence of diagnostic investigations was a transthoracic
followed by transesophageal echocardiography, right and left heart angiography, and
finally magnetic resonance imaging (MRI), as MRI is considered the best imaging modality.[3] Excellent functional and hemodynamic results have been reported after surgical correction.[4] Reconstruction of the pulmonary valve including the right ventricular outflow tract
(RVOT) was considered in this case as previously described.[5] However, reconstruction seemed to provide a questionable approach because of the
massive thickening and fusion of the leaflets. A development of a significant restenosis
in this specific patient is presumed to be unlikely, as the pressure gradient was
dramatically reduced when compared with preoperative values. However, this needs to
be verified in the future by follow-up echos.
The cardiopulmonary bypass was instituted via peripheral vessels as a standard approach
for redo-cases at our institution. After connection to the cardiopulmonary bypass,
the chest was opened and the heart freed from adhesions. Beside the chosen stented
bioprosthesis, there would have been other options for pulmonary valve replacement.
However, especially the stented valves offer the option for future transcatheter pulmonary
valve implantation (e.g., Melody valve, Medtronic, Inc., Minneapolis, Minnesota, United
States) in case of recurrent pulmonary valve stenosis. In the presented case, the
initial plan was a reconstruction of the pulmonary valve and not a valve replacement;
therefore, a pulmonary homograft was not available at the time of operation. Pulmonary
valve replacements with the Carpentier-Edwards PERIMOUNT prosthesis have been described
with good clinical long-term outcomes.[6] When compared with the investigation of Neukamm et al, the size of the implanted
valve (23 mm) was relatively small; however, the RVOT was needed to be enlarged with
a patch to realize the implantation of this valve. In general, the aim was to implant
a valve that is as large as possible with a change of z-scores from −2 (preoperatively)
to −0.5 (postoperatively).