Introduction
According to the American Academy of Sleep Medicine Task Force, obstructive sleep
apnea is the complete interruption of airflow to the airway for at least 10 seconds.
If the anatomical obstacle or the functional change leads to complete prevention of
the inspiratory flow, the patient experiences oxygen desaturation and microarousals,
which is defined as hypopnea.[1]
[2]
Obstructive sleep apnea syndrome (OSAS) affects up to 4% of middle-aged men and 2%
of adult women. Its prevalence increases with age until approximately the seventh
and eighth decades of life; it is more frequent in men and postmenopausal women. The
prevalence of OSAS, defined by Apnea-Hypopnea Index (AHI) frequency and the presence
of hypersomnolence, has been estimated to range from 1.2 to 7.5%.[3] It is strongly associated with obesity, and there is also evidence of a hereditary
component of OSAS.[4]
[5]
[6]
[7]
OSAS has become a concern in clinical practice because of its prevalence and because
it is a potential risk factor for neurologic diseases such as cerebrovascular accidents,
cardiovascular hypertension, acute myocardial infarction, and congestive heart failure,
in addition to obesity and metabolic syndrome. However, it remains underdiagnosed.[1]
[2]
[8]
[9]
[10]
There are many treatment options for OSAS, including positive airway pressure therapy,
oral appliances, and surgery. Oral appliances may be used in patients with mild to
moderate OSAS and in those with more severe disease who are unable to tolerate continuous
positive airway pressure therapy.[11] Thus, the objective of this article is to review the literature to determine which
factors best correlate with treatment success in patients with OSAS treated with a
mandibular repositioning appliance (MRA).
Review of Literature
MRAs, originally derived from functional dental appliances, are used during sleep
to advance the mandible and thus prevent the collapse of oropharynx tissues and tongue
base, thereby reducing events of upper airway obstruction. Because they are simple
and portable, do not use electricity, and are relatively low cost, they are considered
an alternative to the treatment of OSAS. MRAs present favorable results quickly.[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[12]
[13]
The clinical diagnosis of OSAS is confirmed by polysomnography (PSG), which assesses
the parameters of quality, architecture, and sleep continuity; nasal/oral airflow;
qualitative and quantitative measure of respiratory effort; oxyhemoglobin saturation;
electrocardiogram; and position of the body during sleep.[1]
[12]
[14]
The PSG quantifies respiratory events per hour of sleep, and AHI confirms the diagnosis.
This index is the number of times the air passage is blocked (apnea) or reduced (hypopnea)
over 10 seconds each hour of sleep. An AHI of 5 to 15 events per hour is defined as
mild apnea; 16 to 30, moderate apnea; and severe apnea, more than 30.[5]
[12]
According to anthropometric and physiologic predictors, OSAS is a common disease in
the middle-aged population, in general affecting both males and females.[2] Postmenopausal women may have OSAS as frequently as men. Obesity is a known risk
factor directly related to OSAS.[13] Obese individuals with OSAS have a higher fat volume and increase in cervical soft
tissue structures on the airway, causing a reduction in size and alterations in the
function of the respiratory muscles, promoting airflow obstruction.[8]
[9]
[10]
The respiratory problems associated with OSAS result from different anatomical and
pathophysiological changes, which make it difficult to establish a single treatment
that covers all cases. One conventional treatment is the MRA, which generally requires
4 weeks of adaptation to the device followed by 2 to 3 months of stepwise mandibular
advancement (titration of the device) to maximize the acceptance of the appliance.
A mandibular advancement of 50 to 75% of the maximum voluntary protrusion of the individual
has been associated with favorable treatment results.[11]
[12]
[13] The main difficulty is to achieve an adequate mandibular advancement without causing
discomfort to the patient during the first night of use.
Inclusion Criteria for Studies
Type of Study
We reviewed published randomized controlled trials with experimental and control group
addressing the research question: which factors best correlate with treatment success
in patients with obstructive sleep apnea syndrome treated with a mandibular repositioning
appliance.
Type of Participants
Studies with participants of both genders, over 16 years of age, with a diagnosis
of OSAS, and with more than five apneas/hypopneas per hour of sleep were included.
Type of Intervention
The treatment group included studies that reported treatment with any MRA for OSAS;
the control group included studies that reported OSAS treatments using another intervention
(surgical or nonsurgical) or no intervention.
Search Methods
Two reviewers independently performed an electronic search databases of PubMed, Web
of Science, Cochrane Library, Lilacs, and Scielo. The terms used in the literature
review were: [(sleep apnea OR sleep apnoea OR obstructive sleep apnea OR obstructive sleep apnoea
OR sleep apnea syndrome OR sleep apnoea syndrome OR apneic OR apnoea OR respiratory
disturbance OR sleep disorder breathing OR upper airway resistance syndrome) AND (mandibular
repositioning appliance OR mandibular advancement device OR oral appliance OR mandibular
device OR anterior mandibular positioner OR mandibular splint OR oral appliance therapy
OR intraoral sleep apnea devices OR oral jaw-positioning appliance OR intraoral positioning
appliance OR occlusal splint OR anteriorly titratable mandibular positioner OR adjustable
oral appliance OR mandibular advancement splint OR mandibular protruding device OR
mandibular advancing appliance OR oral jaw positioning appliance OR titratable oral
appliance OR oral vestibular shield OR intraoral protrusive appliance)] AND (Randomized
Clinical Trial AND English)]. The electronic search was from January 1988 to January 2012, with language restriction
(English only). Two review authors conducted the electronic search independently.
Data Extraction
Primary outcomes include AHI. Secondary outcomes included other parameters of PSG,
such as quality, architecture, and sleep continuity; nasal/oral airflow; quality and
quantity measurement of respiratory effort; saturation of oxyhemoglobin; oxygen desaturation;
body position; quality of life; and cognitive function.
Data Analysis
The selection of the studies took place in three phases. First, articles were selected
from PubMed, followed by articles from other electronic databases using the search
terms mentioned previously. From these and based on the information provided in the
title and the abstract, examiners selected the articles to read the entire text. Then,
articles in which predictive factors of MRA treatment were possibly discussed were
selected.
The grading of evidence from selected studies was also performed by the same two independent
reviewers according to slight modification of the criteria and classified according
to sample size calculation, randomization, clear definition of the inclusion and/or
exclusion criteria, follow-up completion (and reasons for withdrawal in each study
group were specified), experimental and control group comparable at baseline, presence
of blinding, appropriate statistical analysis, and calibration of examiners.[15]
[16] The total score was calculated for each study and the results regarding quality
were evaluated and considered, as follows: <7 points, high risk of bias (not reviewed);
7 to 10 points, moderate risk of bias; and >10 points, low risk of bias. Moreover,
the strengths and weakness of all the included studies were assessed according to
Cochrane Reviewers' Handbook.[5]
Discussion
Description of Studies
Initially, 69 articles were selected from PubMed and 2 from Cochrane Library. Of these,
30 were excluded based on the title and 12 were excluded based on the abstract, with
29 retrieved for complete reading. Then, 7 articles were excluded because of the methodological
quality of the studies and 6 because the study did not address the research question.
A total of 13 articles and 1 systematic review were considered eligible for further
review and inclusion in this study. The article selection process is charted in [Fig. 1].
Fig. 1 Flowchart.
There was no disagreement about study inclusion between reviewers. The most important
limitation of this study is the heterogeneity of the articles, due to differences
in disease severity and how the authors defined treatment success. [Table 1] lists the studies reviewed by the authors in relation anthropometric and physiologic
factors.[16]
[17]
[18]
[19]
[20]
[21]
Table 1
Studies in relation to anthropometric and physiologic factors
Author
|
Defined treatment success
|
Barnes et al[17]
|
Mild to moderate disease severity. In patients with mild to moderate OSAS, authors
found that CPAP and MRA effectively treated sleep-disorder breathing and sleepiness;
however, the expected response in neurobehavioral function was incomplete. This may
be due to MRA having a lesser therapeutic effect and CPAP being poorly tolerated (used
less in this patient group).
|
Engelman et al[18]
|
Mixed disease severity. Objective sleepiness, cognitive performance, and preference
for treatment were not different. In patients treated with CPAP versus MRA experiencing a mild form of the syndrome (AHI < 15, n = 18), symptoms, treatment efficacy satisfaction, and subjective sleepiness were
better with CPAP than MRA. These results do not support the MRA as first-line treatment
for patients with OSAS.
|
Hoekema et al[19]
|
Mixed disease severity. MRA therapy was less effective in individuals with severe
disease (AHI > 30). Because these patients could be at particular risk for cardiovascular
disease, primary MRA therapy appears to be supported only for those with nonsevere
apnea.
|
Metha et al[20]
|
Mixed disease severity. MRA used in this study was well tolerated, at least in the
short term, and was associated with substantial subjective and objective improvements
in a significant proportion of patients. These results support the use of MRA even
in some of the patients with more severe forms of OSAS.
|
Tan et al[21]
|
Mild to moderate disease severity. (1) MRA may be a suitable alternative to nasal
CPAP in patients with mild to moderate OSAS; (2) larger studies on the long-term efficacy
of the MRA will be required before MRA can be offered as definitive alternative to
nasal CPAP; (3) MRAs were well tolerated and preferred by the majority of patients.
|
Wilhemson et al[22]
|
Mild to moderate disease severity. Findings suggest that the MRA is useful in the
treatment of mild to moderate OSAS.
|
Abbreviations: AHI, apnea-hypopnea index; CPAP, continuous positive airway pressure
therapy; MRA, mandibular repositioning appliance; OSAS, obstructive sleep apnea syndrome.
No randomized controlled trials addressing cephalometric and anatomical factors were
found to be included in this review. Factors related to MRA (titratable, vertical
dimension, and amount of advance), anthropometric and physiologic factors and MRA
(titratable, vertical dimension and amount of advance), and the study founded in Cochrane
Systematic Review are shown in [Table 2].[5]
[23]
[24]
[25]
[26]
[27]
[28]
[29]
Table 2
Factors related to MRA, anthropometric and physiologic factors, and the study found
in Cochrane Systematic Review
Factors related to MRA only
|
Anthropometric and physiologic factors and MRA
|
Cochrane Systematic Review
|
Author
|
Description
|
Author
|
Description
|
Author
|
Description
|
Araab et al[23]
|
In patients with mild to moderate condition titratable during PSG, the authors found
no differences in excessive daytime sleepiness improvements (MRA x nCPAP). This would
indicate that the larger improvements in AHI in the nCPAP group are not clinically
relevant. nCPAP patients may show more problems in accepting nCPAP than MRA patients.
|
Gagnodoaux et al[26]
|
Titrated MRA is an effective therapy in moderately sleepy and overweight patients
with OSAS. Although less effective than CPAP, successfully titrated MRA was very effective
at reducing the AHI and was associated with a higher reported compliance. Both treatments
improved functional outcomes to a similar degree. One night of titration of MRA had
a low negative predictive value for treatment success.
|
Lim et al[5]
|
The review found 16 studies that met the inclusion criteria, comparing treatment with
oral appliances. The authors suggest that future research should recruit patient with
more severe symptoms, to establish whether the response to therapy differs between
subgroups.
|
Araab et al[24]
|
No clinically relevant difference was found between MRA and nCPAP in the treatment
of mild/moderate OSA when both treatment modalities are titrated objectively;
|
Petri et al[27]
|
MRA had significantly beneficial effects on OSA, including cure in some cases of severe
OSA. Protrusion of the mandible is essential for the effect. MRA had no placebo effect
and may be a good alternative to CPAP.
|
Pitsis et al[25]
|
The amount of bite opening induced by MRA does not have a significant impact on treatment
efficacy but does have an impact on patient acceptance.
|
Tegelberg et al[28]
|
MRA recommended for patients of mild to moderate OSAS but recommended to not start
the treatment by more than 50% of mandibular advancement.
|
Walker-Engstron et al[29]
|
MRA could be an alternative treatment for some patients with severe OSAS.
|
Abbreviations: AHI, apnea-hypopnea index; CPAP, continuous positive airway pressure
therapy; MRA, mandibular repositioning appliance; nCPAP, nasal continuous positive
airway pressure therapy; OSAS, obstructive sleep apnea syndrome; PSG, polysomnography.
Summary of Evidence
MRAs are widely prescribed for the treatment of OSAS both as primary therapy and as
an alternative for patients who are unable to tolerate continuous positive airway
pressure therapy. Although significant progress has been made in demonstrating the
efficacy of MRA for OSAS, numerous methodologic weaknesses in published studies bring
uncertainty about the role of this therapy in the routine management of OSAS. Until
the mid to late 1990s, the majority of studies on the use of MRA in OSAS were short
term, not controlled, small, and retrospective. More recently, the quality of MRA
clinical research has become more rigorous.[20]
This review identified 13 randomized controlled trials with low or moderate methodologic
quality involving participants with varied degrees of OSAS severity and 1 systematic
review. However, the evidence to support the ability to predict treatment outcome
and hence to preselect suitable candidates for this treatment option still remains
in its early stages of development.
Predictors of Response to the MRA
The reviewed studies identified a range of anthropomorphic, physiologic, and PSG variables
associated with better treatment outcome. Practice parameters developed by the American
Academy of Sleep Medicine recommend the use of MRAs only for those patients with mild
OSAS or those who refuse or cannot tolerate continuous positive airway pressure therapy.
Several studies support this conclusion. However, there is growing evidence supporting
an expansion of use of MRAs in more severe forms of OSA, provided that patients are
followed cautiously and objective verification of outcome is monitored. The pretreatment
AHI, which reflects disease severity, has been suggested as a possible indicator of
treatment effect in OSAS patients, with generally higher index levels suggesting treatment
failure.[20]
[30]
[31]
[32]
[33] The positive effect of the dental appliance was also independent of whether the
predominant obstruction was in the oropharynx, the hypopharynx, or both.
Some evidence indicates that moderate to severe OSAS is closely associated with obesity
and indicates that the dental appliance is an effective treatment in obese patients.[29]
[34]
Further work is required to determine the most effective design and vertical dimension
opening of MRAs as a predictor of treatment success. The majority of the studies have
compared devices of different design.[20]
[25]
[35]
[36]
The differences in results may be due to differences in the study design, in the way
the MRA was titrated, in the baseline characteristics of the studies participants
(e.g., the severity of OSA), in the primary outcome variable chosen, or in the specifics
of the appliances and devices used. At least in part this uncertainty is related to
how treatment success is defined and what factors can be clinically used as predictors
of success.[37]
[38]
[39]
[40]
[41]
The results of this review justify well-designed, large-scale, randomized controlled
trials to assess the effectiveness of MRA treatment.
Conclusion
This review of the published literature suggests that it is unclear which factors
can be used with confidence to select patients suitable for OSAS treatment with MRAs.
We are only able to make some assertions:
-
Implications of this review for clinical practice: In the absence of clear predictors
of MRA success, it would seem critical to monitor all subjects who have had an MRA
fitted with a further overnight sleep study to make sure that the appliance provides
satisfactory control of the disease.
-
Implication of this review for research: Although significant progress has been reported
in proving the efficacy of MRA for OSAS, the ability to predict treatment outcome
and hence to preselect suitable candidates for this treatment still remains in its
early stages. The review of these clinical trials suggests that there is need to conduct
more randomized control trials comparing MRA with not only other treatments as controls
but also placebo controls. Numerous methodologic weaknesses in published studies bring
uncertainty about the role of this therapy in the routine management of OSAS.