Endoscopic tissue shielding with polyglycolic acid (PGA) sheets (Neoveil; Gunze Co.,
Kyoto, Japan) and fibrin glue (Beriplast P CombiSet; CSL Behring Pharma, Tokyo, Japan)
is a promising method for preventing postoperative complications [1]
[2]
[3]. However, this technique is thought to be inefficient for covering large mucosal
defects because it takes time to deliver many small PGA sheets. Accordingly, we devised
and implemented a new technique involving the delivery of a single large PGA sheet.
A 25-year-old woman with familial adenomatous polyposis was treated using a standard-caliber
endoscope by rectal piecemeal endoscopic mucosal resection, leaving a large mucosal
defect ([Fig. 1]). For our new technique, we used a PGA sheet and its accompanying plastic packaging
sheet. We cut the PGA sheet to cover the artificial ulcer, and then we cut the plastic
sheet to a slightly smaller size. We attached one edge of the plastic sheet to a small-caliber
endoscope with tape. Next, we placed the PGA sheet over the plastic sheet, and we
proceeded to roll the two layers around the small-caliber endoscope like a Swiss roll,
making sure the PGA sheet was on the outside. We placed the enwrapped small-caliber
endoscope inside an overtube (Flexible Overtube; Sumitomo Bakelite Inc., Tokyo, Japan)
to prevent contact with any moisture.
Fig. 1 A large artificial ulcer was present after piecemeal endoscopic mucosal resection.
We delivered the second endoscope within the overtube to the ulcer and then removed
the overtube. Using the biopsy forceps of the standard-caliber endoscope, we grasped
one end of the PGA sheet ([Fig. 2 a]) and fixed it to one edge of the ulcer with clips ([Fig. 2 b]). We proceeded to unroll the PGA sheet over the ulcer ([Fig. 2 c]). The plastic sheet underneath gradually separated from the PGA sheet and remained
curled around the small-caliber endoscope. We then fixed the PGA sheet using several
clips ([Fig. 2 d]). This technique can be used to achieve the delivery of a single large PGA sheet
to cover a sizeable mucosal defect.
Fig. 2 Endoscopic view showing the Swiss roll method for application of a polyglycolic acid
(PGA) sheet to cover an artificial ulcer. a One end of the PGA sheet was grasped using the main endoscope’s biopsy forceps. b The end of the PGA sheet was fixed to one edge of the ulcer with clips. c The PGA sheet was unrolled over the ulcer. d The artificial ulcer was covered with a single large PGA sheet, which was fixed to
the remaining edges of the ulcer using several clips.
Endoscopy_UCTN_Code_TTT_1AQ_2AZ