Esophageal metallic stent fixation with dental floss: a simple method to prevent migration

B. da Costa Martins
Cancer Institute of São Paulo University Medical School, Endoscopy Division, São Paulo, São Paulo, Brazil
,
B. F. Medrado
Cancer Institute of São Paulo University Medical School, Endoscopy Division, São Paulo, São Paulo, Brazil
,
M. S. de Lima
Cancer Institute of São Paulo University Medical School, Endoscopy Division, São Paulo, São Paulo, Brazil
,
F. A. Retes
Cancer Institute of São Paulo University Medical School, Endoscopy Division, São Paulo, São Paulo, Brazil
,
F. S. Kawaguti
Cancer Institute of São Paulo University Medical School, Endoscopy Division, São Paulo, São Paulo, Brazil
,
C. M. P. S. Pennacchi
Cancer Institute of São Paulo University Medical School, Endoscopy Division, São Paulo, São Paulo, Brazil
,
F. Maluf-Filho
Cancer Institute of São Paulo University Medical School, Endoscopy Division, São Paulo, São Paulo, Brazil
› Author Affiliations
Further Information

Corresponding author

B. da Costa Martins
Endoscopy Division
Cancer Institute of São Paulo Medical School
University of São Paulo
Av. Dr. Arnaldo
251 São Paulo
Brazil 01246-000   

Publication History

Publication Date:
25 October 2013 (online)

 

Use of fully and partially covered self-expanding metallic esophageal stents (SEMS) is associated with high rates of migration [1]. Stent modification with a silk thread to permit external fixation, proposed by Shim et al., has been shown to reduce migration [2] but this stent may not be routinely available. Therefore we present another modified stent technique that can be used in patients with or at risk for stent migration.

A piece of dental floss is grasped with a biopsy forceps ([Fig. 1]) and advanced to the esophagus. The endoscope is positioned at the upper border of the stent and the forceps carrying the floss is passed through the stent mesh from the outside to the inside and advanced again ([Fig. 2]). The endoscope is passed further through the stent and the floss is grasped with the forceps and gently pulled back, taking care to avoid stent dislodgment ([Fig. 3]). Finally, using a method similar to exchange of a nasobiliary drainage catheter ([Fig. 4]), the dental floss is drawn out through the nose, and, after having tied a knot into it, its loose end is fixed to the patient’s earlobe. Upper endoscopy is repeated 2 weeks after the procedure and, if the proximal uncovered flange of the stent is embedded in the esophageal mucosa and does not separate from the esophagus with air insufflation, the external fixation is removed.

Zoom Image
Fig. 1 The dental floss is grasped with a small-sized biopsy forceps.
Zoom Image
Fig. 2 a The dental floss is passed through the stent mesh from the outside to the inside. b The floss is then carried down using the biopsy forceps.
Zoom Image
Fig. 3 The dental floss in position.
Zoom Image
Fig. 4 The dental floss is inserted into a nasoenteral tube, which is pushed down towards the mesh to protect the nasopharyngeal mucosa.

This method has been successfully used in eight patients with esophageal malignancies. Of the stents used in these patients, seven were partially covered and one was fully covered. In the patient with the fully covered stent, a needle-knife was used to puncture the sheath, allowing the passage of the dental floss through the mesh. We believe the external fixation using dental floss is a simple and cheap method that can be applied to any kind and size of stent.

Endoscopy_UCTN_Code_TTT_1AO_2AZ


#

Competing interests: None

  • References

  • 1 Verschuur EML, Repici A, Kuipers EJ et al. New design esophageal stents for the palliation of dysphagia from esophageal or gastric cardia cancer: a randomized trial. Am J Gastroenterol 2008; 103: 304-312
  • 2 Shim CS, Cho YD, Moon JH et al. Fixation of a modified covered esophageal stent: its clinical usefulness for preventing stent migration. Endoscopy 2001; 33: 843-848

Corresponding author

B. da Costa Martins
Endoscopy Division
Cancer Institute of São Paulo Medical School
University of São Paulo
Av. Dr. Arnaldo
251 São Paulo
Brazil 01246-000   

  • References

  • 1 Verschuur EML, Repici A, Kuipers EJ et al. New design esophageal stents for the palliation of dysphagia from esophageal or gastric cardia cancer: a randomized trial. Am J Gastroenterol 2008; 103: 304-312
  • 2 Shim CS, Cho YD, Moon JH et al. Fixation of a modified covered esophageal stent: its clinical usefulness for preventing stent migration. Endoscopy 2001; 33: 843-848

Zoom Image
Fig. 1 The dental floss is grasped with a small-sized biopsy forceps.
Zoom Image
Fig. 2 a The dental floss is passed through the stent mesh from the outside to the inside. b The floss is then carried down using the biopsy forceps.
Zoom Image
Fig. 3 The dental floss in position.
Zoom Image
Fig. 4 The dental floss is inserted into a nasoenteral tube, which is pushed down towards the mesh to protect the nasopharyngeal mucosa.