Exp Clin Endocrinol Diabetes 2013; 121(05): 248-254
DOI: 10.1055/s-0032-1331708
Review
© J. A. Barth Verlag in Georg Thieme Verlag KG Stuttgart · New York

The Effect of Using the Insulin Pump Bolus Calculator Compared to Standard Insulin Dosage Calculations in Patients with Type 1 Diabetes Mellitus – Systematic Review

A. Ramotowska
1   Department of Paediatrics, Medical University of Warsaw, Warsaw, Poland
,
D. Golicki
2   HealthQuest, Warsaw, Poland
,
K. Dżygało
1   Department of Paediatrics, Medical University of Warsaw, Warsaw, Poland
,
A. Szypowska
1   Department of Paediatrics, Medical University of Warsaw, Warsaw, Poland
› Author Affiliations
Further Information

Publication History

received 24 July 2012
first decision 12 November 2012

accepted 27 November 2012

Publication Date:
17 January 2013 (online)

Abstract

Background:

Modern insulin pumps use bolus calculators to determine the appropriate insulin dose to facilitate achievement of glycaemic targets.

Objective:

To summarize the data on insulin pump bolus calculators compared to standard insulin dosage calculations and the impact on glycaemic profile.

Methods:

The MEDLINE, EMBASE and Cochrane Library databases were searched until October 2012 for related randomized controlled trials (RCTs) and observational studies performed in type 1 diabetes. A meta-analysis of RCTs was conducted.

Results:

We included 6 trials comprising 354 subjects. Combined data of 2 RCTs showed significantly smaller number of correction boluses in the experimental group (MD  − 2.31; 95% CI:  − 3.59 to  − 1.03; p=0.0004) and a trend toward fewer hypoglycaemic episodes per week (MD  − 0.47; from  − 0.95 to 0.02; 95% CI; p=0.06) in the experimental group compared to control subjects. Other authors reported significant reduction in daily post-prandial blood glucose values in the experimental group compared to controls. The authors observed only one adverse event. More frequent self-monitoring of blood glucose in the experimental group was reported in 3 trials. There were no differences in HbA1c within the groups. Patients were satisfied with the treatment with bolus calculator, according to the treatment satisfaction scale.

Conclusions:

Insulin pump bolus calculators are effective and safe in prandial insulin calculation with a positive impact on glucose profile.

 
  • References

  • 1 Ahola AJ, Mäkimattila S, Saraheimo M et al. FinnDIANE Study Group . Many patients with Type 1 diabetes estimate their prandial insulin need inappropriately. Journal of Diabetes 2010; 2: 194-202
  • 2 Bondia J, Dassau E, Zisser H et al. Coordinated basal-bolus infusion for tighter postprandial glucose control in insulin pump therapy. Journal of Diabetes Science and Technology 2009; 3: 89-97
  • 3 King AB, Armstrong DU. A prospective evaluation of insulin dosing recommendations in patients with type 1 diabetes at near normal glucose control: bolus dosing. Journal of Diabetes Science and Technology 2007; 1: 42-46
  • 4 Pankowska E, Skórka A, Szypowska A et al. Memory of insulin pumps and their record as a source of information about insulin therapy in children and adolescents with type 1 diabetes. Diabetes Technology & Therapeutics 2005; 7: 308-314
  • 5 Heinemann L. Insulin pump therapy: what is the evidence for using different types of boluses for coverage of prandial insulin requirements?. Journal of Diabetes Science and Technology 2009; 3: 1490-1500
  • 6 Glaser NS, Iden SB, Green-Burgeson D et al. Benefits of an insulin dosage calculation device for adolescents with type 1 diabetes mellitus. Journal of Pediatric Endocrinology & Metabolism: JPEM 2004; 17: 1641-1651
  • 7 Zisser H, Wagner R, Pleus S et al. Clinical performance of three bolus calculators in subjects with type 1 diabetes mellitus: a head-to-head-to-head comparison. Diabetes Technology & Therapeutics 2010; 12 955-961
  • 8 Kolassa R, Mühlen H, Maraun M et al. Use of extended functions of modern insulin pumps Diabetes. Stoffwechsel und Herz 2010; 19: 2010
  • 9 Bevier WC, Zisser H, Palerm CC et al. Calculating the insulin to carbohydrate ratio using the hyperinsulinaemic-euglycaemic clamp-a novel use for a proven technique. Diabetes/Metabolism Research and Reviews 2007; 23: 472-478
  • 10 Pickup J, Mattock M, Kerry S. Glycaemic control with continuous subcutaneous insulin infusion compared with intensive insulin injections in patients with type 1 diabetes: meta-analysis of randomised controlled trials. BMJ 2002; 324: 705-708
  • 11 Sussman A, Taylor EJ, Patel M et al. Performance of a glucose meter with a built-in automated bolus calculator versus manual bolus calculation in insulin-using subjects. J Diabetes Sci Technol 2012; 6: 339-344
  • 12 Barnard K, Parkin C, Young A et al. Use of an automated bolus calculator reduces fear of hypoglycemia and improves confidence in dosage accuracy in patients with type 1 diabetes mellitus treated with multiple daily insulin injections. J Diabetes Sci Technol 2012; 6: 144-149
  • 13 Schmidt S, Meldgaard M, Serifovski N et al. Use of an automated bolus calculator in MDI-treated type 1 diabetes: the BolusCal Study, a randomized controlled pilot study. Diabetes Care 2012; 35: 984-990
  • 14 Higgins J, Green S. Cochrane handbook for systematic reviews of interventions. The Cochrane Library, Issue 2. Wiley; Chichester: 2007
  • 15 Gross TM, Kayne D, King A et al. A bolus calculator is an effective means of controlling postprandial glycemia in patients on insulin pump therapy. Diabetes Technology & Therapeutics 2003; 5: 365-369
  • 16 Shashaj B, Busetto E, Sulli N. Benefits of a bolus calculator in pre- and postprandial glycaemic control and meal flexibility of paediatric patients using continuous subcutaneous insulin infusion (CSII). Diabetic Medicine: a Journal of the British Diabetic Association 2008; 25: 1036-1042
  • 17 Garg SK, Bookout TR, McFann KK et al. Improved glycemic control in intensively treated adult subjects with type 1 diabetes using insulin guidance software. Diabetes Ttechnology & Therapeutics 2008; 10: 369-375
  • 18 Klupa T, Benbenek-Klupa T, Malecki M et al. Clinical usefulness of a bolus calculator in maintaining normoglycaemia in active professional patients with type 1 diabetes treated with continuous subcutaneous insulin infusion. The Journal of International Medical Research 2008; 36: 1112-1116
  • 19 Cukierman-Yaffe T, Konvalina N, Cohen O. Key elements for successful intensive insulin pump therapy in individuals with type 1 diabetes. Diabetes Research and Clinical Practice 2011; 92: 69-73
  • 20 Enander R, Gundevall C, Strömgren A et al. Carbohydrate counting with a bolus calculator improves post-prandial blood glucose levels in children and adolescents with type 1 diabetes using insulin pumps. Pediatric Diabetes 2012; 13: 545-551
  • 21 Strojek K, Majkowska L, Zozulińska D et al. Task Force for Postprandial Glycemia. Postprandial glycemia – review of current pathophysiological, epidemiological and clinical aspects. Polskie Archiwum Medycyny Wewnetrznej 2007; 117: 252-259
  • 22 DCCT . The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. The Diabetes Control and Complications Trial Research Group. The New England Journal of Medicine 1993; 329: 977-986
  • 23 Monnier L, Wojtusciszyn A, Colette C, Owens D. The contribution of glucose variability to asymptomatic hypoglycemia in persons with type 2 diabetes. Diabetes Technology & Therapeutics 2011; 13: 813-818
  • 24 Lee SW, Cao M, Sajid S et al. The dual-wave bolus feature in continuous subcutaneous insulin infusion pumps controls prolonged post-prandial hyperglycaemia better than standard bolus in Type 1 diabetes. Diabetes, Nutrition & Metabolism 2004; 17: 211-216
  • 25 Jones SM, Quarry JL, Caldwell-McMillan M et al. Optimal insulin pump dosing and postprandial glycemia following a pizza meal using the continuous glucose monitoring system. Diabetes Technology & Therapeutics 2005; 7: 233-240
  • 26 Laurenzi A, Bolla AM, Panigoni G et al. Effects of carbohydrate counting on glucose control and quality of life over 24 weeks in adult patients with type 1 diabetes on continuous subcutaneous insulin infusion: a randomized, prospective clinical trial (GIOCAR). Diabetes Care 2011; 34: 823-827
  • 27 Bachran R, Beyer P, Klinkert C et al. Initiative; German Pediatric CSII Working Group; BMBF Competence Network Diabetes. Basal rates and circadian profiles in continuous subcutaneous insulin infusion (CSII) differ for preschool children, prepubertal children, adolescents and young adults. Pediatric Diabetes 2012; 13: 1-5