Background: Adequate colon preparation is essential for the quality and accuracy of colonoscopy
and has a significant influence on related costs. The aim of this study was to assess
the efficacy and safety of a novel attachable colon-cleaning device used during colonoscopies
in porcine colon.
Methods: The ClearPath device consists of a multilumen extruded tube with channels for water
irrigation and evacuation designed to allow the break up and removal of stool remnants
during colonoscopy. Seven female domestic swine underwent several series of experiments
in which partial bowel preparation followed by a sedated colonoscopy using the new
device was performed.
Results: Between February 2008 and October 2008, a total of 57 colonoscopic procedures were
conducted. The device enabled rapid cleaning of the partially prepared porcine colon
with no immediate or delayed adverse consequences.
Conclusions: Use of the ClearPath device was found to be a simple, reliable, and safe method for
intraprocedural cleaning of partly prepared porcine colon. These experiments support
a potential role for ClearPath in cleaning the colon in unprepared or poorly prepared
human patients.
References
- 1 DiPalma J A.
Preparation for colonoscopy. In: Waye JD, Rex KD, Williams CB, eds. Colonoscopy principles and practice. Oxford;
Blackwell Publishing 2003: 210-219
- 2
Toledo T K, DiPalma J A.
Colon cleansing preparation for gastrointestinal procedures.
Aliment Pharmacol Ther.
2001;
15
605-611
- 3
ASGE Technology Status Evaluation Report. Colonoscopy preparations.
Gastrointest Endosc.
2001;
54
829-832
- 4 Neidich R L, Zuckerman G R.
Patient preparation. In: Raskin JB, Nord HJ, eds. Colonoscopy principles and techniques. New York; Igaku-Shoin
1995: 53-82
- 5
Burke C, Church J.
Enhancing the quality of colonoscopy: the importance of bowel purgatives.
Gastrointest Endosc.
2007;
66
565-573
- 6
Rex D K, Imperiale T F, Latinovich D R, Bratcher L L.
Impact of bowel preparation on efficiency and cost of colonoscopy.
Am J Gastroenterol.
2002;
97
1696-1700
- 7
Bowles C J, Leicester R, Romaya C. et al .
A prospective study of colonoscopy practice in the U.K. today: are we adequately prepared
for national colorectal cancer screening tomorrow?.
Gut.
2004;
53
277-283
- 8
Aslinia F, Uradomo L, Steele A. et al .
Quality assessment of colonoscopic cecal intubation: an analysis of 6 years of continuous
practice at a university hospital.
Am J Gastroenterol.
2006;
101
721-731
- 9
Harewood G C, Sharma V K, de Garmo P.
Impact of colonoscopy preparation quality on detection of suspected colonic neoplasia.
Gastrointest Endosc.
2003;
58
76-79
- 10
Froehlich F, Wietlisbach V, Gonvers J J. et al .
Impact of colonic cleansing on quality and diagnostic yield of colonoscopy: The European
Panel of Appropriateness of Gastrointestinal Endoscopy European multicenter study.
Gastrointest Endosc.
2005;
61
378-384
- 11
Ben-Horin S, Bar-Meir S, Avidan B.
The outcome of a second preparation for colonoscopy after preparation failure in the
first procedure.
Gastrointest Endosc.
2009;
69
626-630
- 12
Leung F W, Amazonian H S, Leung J W. et al .
Impact of a novel water method on scheduled unsedated colonoscopy in U.S. veterans.
Gastrointest Endosc.
2009;
69
546-50
M. MoshkowitzMD
Department of Gastroenterology
Tel-Aviv Sourasky Medical Center
6 Weizmann St
Tel-Aviv 64239
Israel
Fax: +972-776-201003
Email: Moshkov7@zahav.net.il