Komplettresektion benigner Mammabefunde mittels ultraschallgeführter großlumiger Vakuumbiopsie: medianes Follow-up von 13 Monaten

Complete Resection of Benign Breast Lesions with an Ultrasound-Guided Vacuum Biopsy System with a Median Follow-up of 13 MonthsU. Krainick-Strobel1 , B. Flügel2 , M. Hahn2 , I. Gruber2 , I. Majer2 , K. C. Siegmann3 , F. Fend4 , D. Wallwiener2 , S. Brucker2
  • 1Gemeinschaftspraxis für Brustdiagnostik und Mammografie-Screening Zentrum, Tübingen
  • 2Univ.-Brustzentrum, Frauenklinik Tübingen, Tübingen
  • 3Univ.-Brustzentrum, Abteilung für Radiologische Diagnostik, Tübingen
  • 4Univ.-Brustzentrum, Institut für Pathologie, Tübingen
Further Information

Publication History

Publication Date:
13 December 2010 (online)

Zusammenfassung

Fragestellung:In dieser retrospektiven Studie wurde nach einem Follow-up (FU) von mindestens 6 Monaten untersucht, inwiefern sich die sonografisch geführte Vakuumbiopsie (VB) zur bildgebenden Komplettresektion (KR) benigner Mammabefunde eignet und wo die Grenzen des Verfahrens liegen. Patientinnen und Methoden:Zwischen Februar 2001 und Dezember 2006 wurde bei 299 Patientinnen des Universitäts-Brustzentrums Tübingen eine sonografisch geführte VB durchgeführt. Einschlusskriterien für diese Arbeit waren: benigne Histologie, bildgebende KR per VB, Follow-up-Zeit von mindestens 6 Monaten. Ausschlusskriterien: offene Exzisionsbiopsie innerhalb von 6 Monaten nach VB, maligne Erkrankung ipsilateral. Insgesamt erfüllten 92 Patientinnen mit 100 gutartigen Befunden die Einschlusskriterien. Der Beobachtungszeitraum betrug median: 13,2 Monate, minimal: 6 Monate, maximal: 70,3 Monate. Ergebnisse:Bei angestrebter KR ließen sich 83,5 % der Befunde mit einem maximalen Durchmesser von 18 mm (medianer Durchmesser 13 mm) komplett entfernen. Die KR ist nicht zwingend von der Nadelgröße abhängig, jedoch von der Größe des Befundes und der entnommenen Zylinderanzahl. Positive Tastbefunde konnten bei 75,2 % der Läsionen reduziert werden. Die Komplikationsrate im Sinne von Infektionen und Blutungen ist gering, die auftretenden Komplikationen sind gut behandelbar. Bei 9,8 % der Patientinnen bestand im FU der Verdacht auf das sonografische Bild einer Narbe (medianer Durchmesser 6 mm) im biopsierten Bereich. Schlussfolgerung:Es konnte gezeigt werden, dass die sonografisch geführte VB aufgrund der hohen KR- und der niedrigen Komplikationsrate sowie der guten kosmetischen Ergebnisse eine sinnvolle minimalinvasive Alternative zur chirurgischen Exzisionsbiopsie ist. Diese Ergebnisse bestätigten sich auch im Langzeitverlauf.

Abstract

Purpose:This study investigated whether ultrasound-guided vacuum biopsy (VB) with curative intent is suitable for the complete extirpation of selected, sonographically detectable, benign breast lesions, and evaluated the limitations of the method. Our study is based on a long-term median follow-up of 13 months (minimum follow-up 6 months). Patients and Methods:Between February 2001 and December 2006 299 patients underwent hand-held, ultrasound-guided VB at the Tuebingen University Breast Center. Inclusion criteria: biopsy was performed with the intention of complete resection and the lesion showed a benign histology, and clinical and sonographical follow-up was carried out for at least 6 months after the biopsy, meaning that the patient did not undergo surgery of the biopsied area during that period. A total of 92 patients with 100 lesions were followed up clinically and sonographically for an average of 13.2 months. Results:A complete removal of sonographically visible lesions (median diameter 13.0 mm) was achieved in 83.5 % of all cases if leasions measured 18 mm or less. Palpable lesions could be reduced by VB in 75.2 % of cases. Complications such as infections or minor bleeding were rare and well treatable. 9.8 % of patients had suspected scar formation at the biopsy site. Conclusion: VB is an ambulatory procedure associated with little pain. It is a minimally invasive biopsy technique for benign lesions and a good alternative to open excision with a high degree of acceptance by patients. Complications are rare and similar to that observed with conventional microbiopsy. Results were confirmed by a long-term median follow-up of 13 months (minimum 6 months).

Literatur

  • 1 Krainick-Strobel U, Hahn M, Duda V F Arbeitsgemeinschaft Minimalinvasive Mammainterventionen (AG MiMi) der Deutschen Gesellschaft für Senologie (DGS) et al.,. Konsensusempfehlung zu Anwendung und Indikationen der Vakuumbiopsie der Brust unter Ultraschallsicht.  Geburtsh Frauenheilk. 2005;  5 526-529
  • 2 Heywang-Köbrunner S H, Schreer I, Decker T et al. Interdisciplinary consensus on the use and technique of vacuum-assisted stereotactic breast biopsy.  Eur J Radiol. 2003;  47 232-236
  • 3 Krainick-Strobel U, Huber B, Majer I et al. Complete extirpation of benign breast lesions with an ultrasound-guided vacuum biopsy system.  Ultrasound Obstet Gynecol. 2007;  29 342-346
  • 4 Sperber F, Blank A, Metser U et al. Diagnosis and treatment of breast fibroadenomas by ultrasound-guided vacuum-assisted biopsy.  Arch Surg. 2003;  138 796-800
  • 5 Hahn M, Krainick U, Peisker U et al. Eignet sich das Handheld Mammotome® zur kompletten Entfernung benigner Läsionen der Brust?.  Geburtsh Frauenheilk. 2004;  64 719-722
  • 6 Povoski S P, Jimenez R E. A comprehensive evaluation of the 8-gauge vacuum-assisted Mammotome® system for ultrasound-guided diagnostic biopsy and selective excision of breast lesions.  World J Surg Oncol. 2007;  5 83
  • 7 Huber S, Wagner M, Medl M et al. Benign breast lesions: Minimally invasive vacuum-assisted biopsy with 11-Gauge needles – patient acceptance and effect on follow-up imaging findings.  Radiology. 2003;  226 783-790
  • 8 Ko E Y, Bae Y A, Kim M J et al. Factors affecting the efficacy of ultrasound-guided vacuum-assisted percutaneous excision for removal of benign breast lesions.  J Ultrasound Med. 2008;  27 65-73
  • 9 Baez E, Huber A, Vetter M et al. Minimal invasive complete excision of benign breast tumors using a three-dimensional ultrasound-guided mammotome vacuum device.  Ultrasound Obstet Gynecol. 2003;  21 267-272
  • 10 Krainick-Strobel U, Majer I, Huber B et al. Development of a gel-simulation model and generation of standard tables for the complete extirpation of benign breast lesions with vacuum assisted biopsy under ultrasound guidance.  Ultrasound Med Biol. 2006;  32 1539-1544
  • 11 Hahn M, Okamgba S, Scheler P et al. Vacuum-assisted breast biopsy: a comparison of 11-gauge and 8-gauge needles in benign breast disease.  World J Surg Oncol. 2008;  6 51

PD Dr. med. U. Krainick-Strobel

Gemeinschaftspraxis für Brustdiagnostik und Mammografie-Screening Zentrum

Karlstraße 8

72072 Tübingen

Email: info@brustdiagnostik-tue.de

    >