A 41-year-old man experienced abdominal pain after consuming greasy food and was diagnosed
with a pancreatic pseudocyst following acute necrotizing pancreatitis ([Fig. 1]
a), undergoing endoscopic ultrasound (EUS)-guided drainage with a lumen-apposing metal
stent (LAMS, Boston Scientific). During the cystogastrostomy procedure, the LAMS inadvertently
dislodged completely into the pseudocyst ([Fig. 1]
b). Double pigtail stents and a nasocystic drainage tube were immediately placed intraoperatively
to ensure continuous drainage of the cyst fluid.
Fig. 1 The process of failed LAMS placement and the successful repositioning outcome. a Preoperative CT imaging of the pancreatic pseudocyst. b First intraoperative puncture showing no LAMS in the gastric cavity. c Second intraoperative ultrasound showing the LAMS dislodged into the cyst. d Postoperative CT after the second procedure showing successful repositioning of the
LAMS and cyst shrinkage. Abbreviation: LAMS, lumen-apposing metal stent.
One week later, imaging demonstrated significant shrinkage of the pseudocyst ([Fig. 1]
c), and the patient remained asymptomatic, with no signs of infection or bleeding.
Given the favorable clinical outcome, we decided to attempt endoscopic repositioning
of the dislodged LAMS ([Video 1]). First, the displaced stent was localized within the pseudocyst under EUS guidance.
Subsequently, a needle knife was advanced over a guidewire through the original puncture
tract, successfully entering the pseudocyst cavity. A 2 cm dilation balloon was then
used to expand the tract between the gastric and cyst walls, preparing for the next
step.
The process of endoscopically inserting a wire into the cyst, performing dilation,
and repositioning the LAMS.Video 1
Using a therapeutic gastroscope (1.0 cm outer diameter) guided by the wire, the operator
advanced into the pseudocyst, where extensive necrotic debris was encountered. After
repeated careful exploration, the dislodged LAMS was identified. With the assistance
of forceps, the position of the LAMS was adjusted. One end of the stent was gently
pulled into the gastric lumen, while the other end was kept inside the pseudocyst.
The stent was then repositioned to securely anchor between the gastric and cyst walls,
successfully re-establishing an effective drainage pathway.
After repositioning, the gastroscope passed smoothly through the LAMS into the pseudocyst,
and normal cyst drainage resumed (Fig. 1d). This case demonstrates that endoscopic
repositioning of a dislodged LAMS is a feasible and safe strategy, offering an effective
and minimally invasive alternative for the treatment of pancreatic pseudocysts.
Endoscopy_UCTN_Code_CPL_1AK_2AG
E-Videos is an open access online section of the journal Endoscopy, reporting on interesting cases and new techniques in gastroenterological endoscopy.
All papers include a high-quality video and are published with a Creative Commons
CC-BY license. Endoscopy E-Videos qualify for HINARI discounts and waivers and eligibility is automatically checked during the submission
process. We grant 100% waivers to articles whose corresponding authors are based in
Group A countries and 50% waivers to those who are based in Group B countries as classified
by Research4Life (see: https://www.research4life.org/access/eligibility/).
This section has its own submission website at https://mc.manuscriptcentral.com/e-videos.