Keywords thyroid - V-flow - hemodynamics/flow dynamics - multimdodal sonographic imaging -
adenocarcinoma - microvascularization
Introduction
In recent years the incidence of thyroid carcinoma has been on the rise, reaching
up to 10 per 100,000 women and 3 per 100 000 men in 2020 – while its relative share
among all malignant tumors has remained relatively stable at approximately 1 percent
[1 ]. Unfortunately, as the number of diagnosed thyroid tumors rises, there is a corresponding
increase in the number of thyroid surgeries, resulting in a higher incidence of complications.
These complications include recurrent laryngeal nerve damage resulting in dysphonia,
post-surgical hypoparathyroidism as well as aesthetic damage due to surgical scars
[2 ]. To reduce these undesired side effects, it is crucial to improve the noninvasive
diagnostic workup of thyroid nodules, thereby allowing precise identification of malignant
thyroid lesions and ensuring surgical removal is limited exclusively to necessary
cases.
Ultrasound imaging of the thyroid gland plays a pivotal role in evaluating thyroid
nodules, enabling the differentiation between benign nodules and those with malignant
characteristics. Various classification systems, such as the well-known TI-RADS classification,
have been established for this purpose [3 ]. The TI-RADS classification is a five-point classification system using ultrasound
criteria to assess thyroid nodules. However, it is worth noting that intranodular
perfusion is not currently considered as a criterion within the TI-RADS classification.
Nevertheless, the perfusion or hemodynamic alteration within a tumor serves as an
indicator of its status [4 ]
[5 ]. There are several established sonographic modes showing the blood flow in and around
possible malignant lesions: Color-coded Doppler sonography (CCDS) and high-resolution
flow (HR Flow) can detect macrovascularization [6 ]. After injecting a contrast agent, contrast-enhanced ultrasound (CEUS) can depict
perfusion patterns including smaller blood vessels [7 ]
[8 ]. The new V-flow mode goes beyond these techniques by providing dynamic visualization
of microvascularization up to capillary perfusion, even showing the movement of single
erythrocytes [9 ]
[10 ]
[11 ]
[12 ]. Despite not being incorporated into the TI-RADS classification, intranodular perfusion
holds promise as an additional criterion for enhancing the accuracy of thyroid nodule
assessment.
Up to this point vector flow (V-flow) was only utilized to assess large brain-supplying
arteries and veins [12 ]. This study represents the first documented analysis of V-flow in the assessment
of solid thyroid tumors. The aim of this study was to investigate whether the new
V-flow mode contributes to a more precise preoperative differentiation of thyroid
lesions, thereby reducing unnecessary thyroid surgery and fine needle aspiration (FNA)
procedures. We reviewed various qualitative and quantitative V-flow findings based
on their ability to predict thyroid lesions as benign or malignant.
By combining V-flow with existing ultrasound modes, our aim was to enhance the sensitivity
of ACR and EU-TI-RADS from 78–88% to the level of cytology, which typically ranges
from 76–98% [13 ]
[14 ]
[15 ].
Materials and Methods
The retrospective study was approved by the local ethics committee.
The inclusion criteria of this study were the same as those used for operative (hemi-)thyroidectomy,
which were defined in-house. These criteria comprised lymph node metastases potentially
originating from the thyroid gland, symptoms such as breathing and swallowing difficulties,
elevated levels of calcitonin tumor marker in the blood count, suspicious preliminary
sonographic examinations resulting in a TI-RADS IV or V rating, or lesions appearing
as a cold node on scintigraphy. The frequency of these inclusion findings among the
101 patients is displayed in [Table 1 ].
Table 1 Absolute and percentage study inclusion criteria.
Inclusion criteria
Absolute number
Percentage
Notes
Lymph node metastases possibly originating from thyroid
4
4.0%
3 derived from thyroid cancer
Elevated calcitonin levels in blood count
2
2.0%
Allowed for the detection of the 3mm medullary microcarcinoma
TI-RADS IV or V
61
60.4%
Most frequent inclusion criterion
Cold node on scintigraphy
27
26.7%
Scintigraphy was only performed on lesions ≥ TI-RADS III
Breathing/swallowing difficulties
12
11.9%
A total of 101 patients with suspicious non-cystic and solid thyroid lesions were
consecutively enrolled from Jan. 1, 2023 to Aug. 31, 2023 in this retrospective study.
The examinations were conducted using a high-performance ultrasound device (Resona
7/R9; Mindray, Shenzen, China) equipped with a multifrequency matrix linear probe
(Mindray L9–3U Linear Array transducer, 3 to 7.0 MHz). The examinations were documented
as single pictures or cine-loops, which were saved as digital DICOM files.
The size of each thyroid gland and its nodules was measured in three dimensions. The
morphology of the lesion on B-mode was assessed using EU-TI-RADS criteria [3 ].
V-flow examination technique
V-flow visualizes blood flow patterns with a frequency of 6 to 8MHz by featuring arrows
that differ in number, direction, length, location, and color. Additionally, it provides
quantitative data on the degree of turbulence. In V-flow, three main types of arrows
or vectors are observed: short green arrows as well as yellow and red vectors indicating
flow moves forward from the dotted green arrows in the frame [9 ]. For each V-flow examination an adjustable window was set on the respective thyroid
nodule. The sonomorphological hemodynamics of the lesion in V-flow were assessed by
the following predicted malignancy criteria: turbulence (vectors running in opposite
directions) both inside and outside the adjustable window as well as lack of red vectors
within the V-flow window.
In terms of quantitative data, the study focused on the maximum and mean velocity
[cm/s] of blood flow as well as the degree of turbulence [%] at the point of maximum
velocity. Both qualitative and quantitative data were reproducible by two separate
investigators. Since no prior experience with the application of V-flow for a thyroid
gland has been reported, the technical preset of this mode had to be modified for
both high-flow arteries and low-flow veins [10 ]
[12 ]. 23 cm/s was the lowest velocity V-flow was able to measure. Considering that carcinomas
tend to exhibit inhomogeneous blood vessels with a chaotic slow flow, we anticipated
that the V-flow mode would show more non-directional green and yellow arrows in malignant
tumors compared to benign tumors and healthy thyroid tissue [16 ].
It is important to note that V-flow was always part of a comprehensive multimodal
sonographic examination that also included B-mode, CCDS, shear-wave elastography,
and CEUS [7 ]. By combining the new V-flow mode with established sonographic techniques, morphological
and hemodynamic alterations of blood vessels can be analyzed more extensively.
Statistical analysis
Statistical analyses were conducted using SPSS 28.0 (SPSS Inc., Chicago, IL, USA).
The Kruskal–Wallis test was utilized to compare the measured values between the benign
and malignant nodules and to determine statistical significance. Probabilities less
than 0.05 were considered to be statistically significant. The ROC curve and the Youden’s
J statistic were employed to calculate cut-off values with a high sensitivity and
specificity for the quantitative V-flow data including: maximum velocity [cm/s], mean
velocity [cm/s], and turbulence [%] at the point of maximum velocity. Binary logistic
regression was used to determine the diagnostic odds ratio (DOR).
Results
101 patients (38 males, 63 females) with an age range of 27 to 85 years and a mean
age of 58 ± 16 years were included in this study. Inter- or postoperative histopathological
analysis showed 93 benign thyroid nodules and 8 carcinomas. Among the carcinomas,
6 were identified as papillary and 2 as medullary thyroid carcinomas. All carcinomas
were surgically removed via thyroidectomy. The diameters of the benign regressive
thyroid nodules ranged from 4 to 104 mm, with a mean diameter of 22 ± 15 mm. On the
other hand, the diameter of the carcinomas ranged from 3 to 16 mm, with a mean diameter
of 9 ± 4 mm.
Hemodynamic V-flow findings
Turbulence occurred five times more often in carcinomas (87.5%) than in benign nodules
(17.2%), as shown in [Table 2 ]. Furthermore, the carcinomas exhibited a lack of red fast arrows nearly twice as
often and turbulence close to them occurred more than twice as frequently when compared
to benign nodules. Examples illustrating these findings can be seen in [Fig. 1 ], [Fig. 2 ] and [Fig. 3 ].
Table 2 Frequency of malignant V-flow findings in benign and malignant thyroid nodules.
V-flow findings
Benign
Malignant
Turbulence within the lesion
17.2%
87.5%
Turbulence near the lesion
29.0%
75%
No red arrows within the lesion
39.8%
75%
Fig. 1 V-flow examination of a left thyroid lobe with a TI-RADS V thyroid tumor (papillary
thyroid carcinoma): Green and yellow but no red arrows within the lesion. Turbulences
in and around the lesion (white arrows) in V-low a . The lesion (white circle) shows mixed echogenicity, microcalcifications, and a diffuse
edge demarcation in B-mode b.
Fig. 2 V-flow examination of a left thyroid lobe with a TI-RADS III benign thyroid nodule:
Green, yellow, and red arrows streaming linearly in the same direction (white arrow).
No turbulence inside or outside the examination window in V-flow a . The lesion (white circle) presents with hyperechoic edge demarcation but without
microcalcifications in B-mode b.
Fig. 3 V-flow examination of a right thyroid lobe without any lesion or nodule: Vectors only
appear along the edges of the thyroid gland or in nearby blood vessels but not within
the thyroid gland.
[Fig. 1 ] depicts the V-flow and B-mode image of a histopathologically proven thyroid carcinoma.
The malignant lesion exhibits characteristic malignant features, including the presence
of turbulence. This turbulence is represented by vectors positioned close together,
running in different directions both within and outside of the lesion. Furthermore,
within the examination window covering the lesion, green and yellow arrows are observed,
while red arrows are absent.
[Fig. 2 ] shows the V-flow and B-mode examination of a histopathologically proven benign regressive
thyroid nodule. The blood stream within the benign lesion appears homogeneous, without
any significant turbulence within or outside the examination window. All vectors are
observed to flow in the same direction. Notably, fast red vectors were observed within
the benign nodule.
[Fig. 3 ] pictures the V-flow examination of a right thyroid lobe without any lesions. No
vectors appear within the healthy thyroid tissue.
Maximum velocity, mean velocity, and turbulence measurements
[Table 3 ] summarizes the results of the quantitative V-flow measurements including maximum
velocity [cm/s], mean velocity [cm/s] of blood flow, and the degree of turbulence
[%] at the point of maximum velocity. Benign regressive thyroid nodules exhibit higher
maximum and mean velocity, along with lower standard deviations, indicating a faster
and more homogeneous blood stream in benign lesions. On the other hand, carcinomas
display a higher mean degree of turbulence compared to benign lesions. The highest
turbulence value of 94.4% at the point of maximum velocity was also measured in a
thyroid carcinoma. Therefore, carcinomas usually show a slow, inhomogeneous, and turbulent
blood flow. Statistical analysis reveals significant differences between the two groups
in terms of mean velocity (p = 0.039) and turbulence (p = 0.016), while the difference in maximum velocity is not statistically significant
(p = 0.062).
Table 3 Average absolute velocity [cm/s] and turbulence [%] measurements in benign and malignant
thyroid nodules and their p -value.
V-flow measurements
Malignant (n ± STD)
Benign (n ± STD)
p
Maximum velocity [cm/s]
48.9 ± 46.2
74.9 ± 40.3
0.062
Mean velocity [cm/s]
10.7 ± 3.7
19.5 ± 14.0
0.039
Turbulence [%]
46.7 ± 20.9
26.1 ± 21.7
0.016
Examples illustrating these findings are provided in [Fig. 4 ] and [Fig. 5 ].
Fig. 4 V-flow examination of a right thyroid lobe with a TI-RADS V tumor, later identified
as medullary thyroid carcinoma: Results of the quantitative measurements, including
maximum velocity [cm/s] (white box), mean velocity [cm/s] (grey box), and turbulence
[%] (yellow box) displayed above the ultrasound examination window. Mean velocity
measurement value: 5.7 cm/s. Maximum velocity measurement: 15.9 cm/s. Degree of turbulence:
76.2% at the point of maximum velocity.
Fig. 5 V-flow examination of a right thyroid lobe with a benign TI-RADS III thyroid nodule.
Results of the quantitative measurements, including maximum velocity [cm/s] (white
box), mean velocity [cm/s] (grey box) and turbulence [%] (yellow box) depicted above
the ultrasound examination window. Mean velocity value: 24.1 cm/s. Maximum velocity
value: 103.8 cm/s. Degree of turbulence: 13.1% at the point of maximum velocity.
[Fig. 4 ] depicts the V-flow examination of a histopathologically proven medullary thyroid
carcinoma. The mean velocity measurement value was found to be 5.7 cm/s, which is
below our calculated cut-off value of 12.3 cm/s. However, the carcinoma displays a
high degree of turbulence, specifically 76.2% at the point of maximum velocity, significantly
surpassing our calculated cut-off value of 25.9%.
[Fig. 5 ] shows the V-flow examination of a histopathologically proven benign regressive thyroid
nodule. The nodule reaches a high mean velocity value of 24.1 cm/s which surpasses
our calculated cut-off value of 12.3 cm/s. The benign lesion displayed a low degree
of turbulence, measuring 13.1% at the point of maximum velocity, which is below our
calculated cut-off value of 25.9%.
Cut-off values, sensitivity, specificity, diagnostic accuracy, and diagnostic odds
ratio
In order to find a more precise demarcation between benign and malignant thyroid nodules
in V-flow, cut-off values for mean velocity as well as for turbulence were calculated.
Since there was no statistically significant difference in maximum velocity, a cut-off
value for this category was not calculated. It is important to note that as the percentage
of turbulence increases and the mean velocity decreases, the likelihood of the lesion
being classified as malignant also increases.
The diagnostic accuracy, DOR, sensitivity, and specificity for each mentioned V-flow
finding and measurement are listed in [Table 4 ]. Turbulence within the lesion achieved the highest diagnostic accuracy and DOR.
The highest sensitivity value of 87.5% was achieved by the mean velocity and turbulence
cut-off values, as well as the presence of turbulence within the lesion. On the other
hand, the presence of turbulence within the lesion exhibited the highest specificity
value of 82.8%.
Table 4 Nominal V-flow findings and cut-off values with their diagnostic accuracy, DOR, sensitivity,
and specificity.
V-flow findings
Diagnostic accuracy (%)
Diagnostic Odds Ratio
Sens. (%)
Spec. (%)
Turbulence within the lesion
83.2
33.69
87.5
82.8
Turbulence near the lesion
71.3
17.11
75.0
70.1
Lack of red arrows within the lesion
61.4
4.75
75.0
60.2
Mean velocity [cm/s]
Cut-off: 12.3 cm/s
73.3
0.88
87.5
64.8
Turbulence [%]
Cut-off: 25.9 %
69.3
1.1
87.5
59.2
Representative cases in V-flow and multimodal sonographic imaging
We selected three cases to illustrate representative findings in V-flow imaging: one
case depicting a malignant lesion ([Fig. 6 ]), another demonstrating a benign lesion ([Fig. 7 ]), and a third presenting an ambiguous lesion ([Fig. 8 ]). For the final lesion status decision, we considered malignancy criteria of different
ultrasound modes: B-mode, CCDS, or high-resolution flow, strain or shear-wave elastography,
and CEUS.
Fig. 6 Multimodal sonographic examination of a right thyroid lobe with a suspicious TI-RADS
V thyroid tumor (papillary thyroid carcinoma): Turbulence and a lack of red arrows
in V-flow a . Microcalcifications and low echogenicity on B-mode b . Inhomogeneous marginal hypervascularization on color-coded Doppler sonography c . Central and marginal hard areas on strain elastography d . Early marginal wash-in (white arrows) 12 seconds after injection of 20 ml of SonoVue
as contrast agent e as well as wash-out (white arrows) on contrast-enhanced ultrasound 1 minute and one
second after starting the examination f.
Fig. 7 Multimodal sonographic examination of a right thyroid lobe with a benign TI-RADS III
thyroid tumor: Homogeneous linear flow without turbulence but with red arrows in V-flow
a . Clear edge demarcation and no microcalcifications on B-mode b . Moderate vascularization across the entire lesion in on color-coded Doppler sonography
c . Rather soft structure on shear-wave elastography d . Delayed homogeneous wash-in across the whole lesion e 18 seconds after contrast agent injection as well as no wash-out on contrast-enhanced
ultrasound.
Fig. 8 Multimodal sonographic examination of a right thyroid lobe with an ambiguous TI-RADS
IVa thyroid tumor: Linear blood stream with a turbulence measurement of 23.34% in
V-flow a . Diffuse edge demarcation and an inhomogeneous sonomorphological structure on B-mode
b . Moderate vascularization across the whole lesion on color-coded Doppler sonography
c . Diffuse hard areas across the whole nodule on strain elastography d . Early marginal wash-in 12 seconds after contrast agent injection e as well as marginal wash-out 1 minute and 9 seconds after the start of the examination
f on contrast-enhanced ultrasound. Histopathology identified a papillary thyroid carcinoma.
Every ultrasound mode in [Fig. 6 ] reveals different malignant findings associated with the suspicious lesion, which
was rated as TI-RADS V: Turbulence and a lack of red arrows in V-flow; microcalcifications
and low echogenicity on B-mode; inhomogeneous marginal hypervascularization on CCDS;
central and marginal hard areas on strain elastography; early marginal wash-in as
well as a wash-out phenomenon one minute after the injection of the contrast agent
on CEUS.
Collectively, these findings strongly indicate the presence of a malignant thyroid
tumor. Histopathology confirmed this tumor to be a papillary thyroid carcinoma.
The different ultrasound modes in [Fig. 7 ] show several benign findings associated with the suspicious lesion, which was rated
as TI-RADS III: Homogenous linear flow with red arrows but without turbulence in V-flow;
clear edge demarcation and no microcalcifications on B-mode; moderate vascularization
across the entire lesion on CCDS; a rather soft structure on shear-wave elastography;
delayed homogeneous wash-in across the whole lesion as well as no wash-out on CEUS.
Taking all of these findings into account, they collectively suggest that the thyroid
nodule is benign in nature. Histopathology confirmed this tumor as a benign regressive
thyroid nodule.
[Fig. 8 ] depicts an ambiguous TI-RADS IVa thyroid tumor. Notably, the V-flow and CDDS examination
results differ from several other ultrasound modes: V-flow shows a rather linear blood
stream with a turbulence measurement of 23.34%, which is below our calculated cut-off
value of 25.0%. CCDS visualizes vascularization across the whole lesion. These findings
would indicate a benign lesion. However, the other ultrasound modes reveal several
malignant findings: diffuse edge demarcation and an inhomogeneous sonomorphological
structure on B-mode; diffuse hard areas across the whole nodule on strain elastography;
early marginal wash-in as well as a marginal wash-out phenomenon one minute and ten
seconds after the injection of the contrast agent on CEUS. V-flow and CCDS suggest
a benign tumor, whereas B-mode, elastography, and CEUS indicate a malignant thyroid
nodule. Histopathology confirmed this tumor as papillary thyroid carcinoma. This case
underscores the importance of considering multiple ultrasound modes in the evaluation
of suspicious thyroid lesions. In this specific case, CEUS and elastography proved
to be more effective in identifying malignancy, despite other modes suggesting a benign
lesion. Adopting a comprehensive approach that incorporates various ultrasound modes
can significantly improve the accuracy of thyroid nodule assessment and play a pivotal
role in guiding appropriate clinical management and treatment decisions.
V-flow scoring system
We developed a comprehensive scoring system based on the evaluation of our results,
which consists of five V-flow malignancy criteria. These criteria include the presence
of turbulence within or next to the lesion; a lack of red arrows in the box set across
the thyroid lesion; mean velocity below 12.3 cm/s as well as turbulence measurements
of the lesion at the point of maximum velocity above 25.9%. Each criterion, when met,
contributes one point to the score. Thyroid nodules are assigned a V-flow score based
on the number of criteria met. If a thyroid nodule achieves a V-flow score of 4 or
5, it is predicted to be malignant.
The score-based V-flow scheme demonstrates a sensitivity of 100.0%, a specificity
of 84.9%, a positive predictive value (PPV) of 0.36, and a negative predictive value
(NPV) of 1.0 as presented in [Table 5 ]. These values change to 87.5%, 94.6%, 0.58, and 0.99 respectively, if 5 points are
required to indicate a high risk of malignancy.
Table 5 Sensitivity, specificity, PPV, and NGV of V-flow scoring system for the prediction
of malignancy.
V-flow scoring system
Sensitivity
Specificity
PPV
NPV
If ≥ 4 points are required for predicting malignancy
100.0%
84.9%
0.362
1.0
If 5 points are required for predicting malignancy
87.5%
94.6%
0.582
0.989
Conclusions
Up to this point the novel ultrasound technique V-flow has only been used for large
brain-supplying arteries and veins [10 ]
[12 ]. However, this study represents the first reported findings on the utilization of
V-flow for solid thyroid tumors. Our results demonstrate that V-flow shows promise
in distinguishing between benign and malignant thyroid nodules, particularly when
used in conjunction with CEUS to assess microvascularization. Malignant lesions exhibit
a turbulent and slow flow profile in V-flow, which matches the documented chaotic
and turbulent perfusion seen in carcinomas [7 ]
[17 ]
[18 ]. Moreover, integrating V-flow with established ultrasound modes such as B-mode,
elastography, CCDS, and CEUS could enhance their diagnostic capabilities. Consequently,
the number of unnecessary thyroid surgeries for benign lesions could potentially be
reduced by up to 70%. Furthermore, V-flow could serve as a valuable addition to the
TI-RADS classification, which currently relies solely on B-mode. However, it is important
to note that further multicenter studies are needed to further validate its efficacy
and establish standardized qualitative and quantitative techniques for V-flow examination.
Discussion
The findings of our study demonstrate that malignant thyroid tumors often exhibit
turbulent blood flow with reduced blood stream velocity in V-flow. Carcinomas exhibit
inhomogeneous microvascularization and chaotic blood vessels especially along their
margins as well as shunts where blood cannot flow linearly. Consequently, blood flow
becomes turbulent and fails to reach the higher velocity values typically observed
in linear directed blood vessels found in benign thyroid nodules [7 ]
[18 ]. Detecting these perfusion patterns requires the application of dynamic imaging
techniques.
If the decision for a (hemi-)thyroidectomy had depended on our newly developed scoring
system, the number of patients with benign nodules undergoing surgery would have decreased
from 71 out of 93 patients to only 5. This represents a remarkable reduction of 70%.
After all, V-flow did not allow for a definitive differentiation between benign and
malignant thyroid lesions in all cases. Further sonographic examinations were required
to enhance the informative value of V-flow in these cases.
In 5 cases, benign lesions received a V-flow score of 4 or higher, leading to an incorrect
classification as malignant. To address this, multimodal sonographic imaging consisting
of B-mode, CCDS, elastography, and CEUS was applied to those 5 nodules, which were
initially classified as malignant based on the V-flow score. The 5 nodules showed
several benignity criteria in multimodal sonographic imaging: 4 of them exhibited
well-defined edges and lacked microcalcifications in B-mode, 3 were depicted as rather
soft on elastography, 3 displayed homogeneous vascularization throughout the entire
nodule and none of them exhibited a fast wash-in or a wash-out phenomenon on CEUS
[7 ]. On the other hand, some of the carcinomas also showed signs of benignity on multimodal
sonographic imaging: 2 did not have microcalcifications, 1 had clear edge demarcation,
1 was soft, and 2 did not show any sign of wash-out on CEUS. Consequently, we can
draw the following conclusion: Neither V-flow nor any other single sonographic technique
should be the sole determining factor in deciding whether a thyroid lesion is benign
or malignant. However, V-flow enhances the evaluation of microvascular hemodynamics
in thyroid tumors, making it a valuable addition to established ultrasound modes for
clarifying thyroid pathologies prior to surgical histopathological examination. To
comprehensively assess sonomorphology, density, macro- and microvascularization of
a thyroid node, we recommend following our own published study protocol: starting
sonography with B-mode considering TI-RADS, followed by strain- and shear-wave elastography
as well as CCDS. Subsequently, a dynamic evaluation using a 4-minute CEUS examination
should be performed [4 ]
[5 ]
[6 ]. Based on our own results and the TI-RADS classification, multimodal sonographic
imaging is essential for detecting and characterizing thyroid tumors [3 ]
[6 ]. Particularly, CEUS facilitates further analyzation of TI-RADS IVa and IVb nodules.
Strain and shear-wave elastography enable a more detailed differentiation of benign
and malignant TI-RADS III and IV lesions, which show mixed echogenicity on B-mode.
V-flow offers new possibilities for visualizing irregular turbulent neovascularization
in carcinomas or homogeneous marginal vascularization in benign lesions. Therefore,
it contributes to a more precise examination of vascularized nodules, which are classified
as TI-RADS III and up. The volume of thyroid lesions could be a relevant factor for
malignancy, with carcinomas having a slightly higher average value, which is consistent
with small benign lesions showing no signs of neovascularization.
We compared the malignancy and benignity prediction of the V-flow scoring system to
TI-RADS, elastography, and CEUS. Our V-flow scoring system reaches a sensitivity of
100.0% and a specificity of 84.9%. In our group of patients, elastography shows a
sensitivity of 75.2% and a specificity of 81.2% and CEUS a sensitivity of 67.4% and
a specificity of 95.0%. According to multi-center studies, EU-TIRADS achieves values
of 75.0% and 94.1% [19 ], elastography 74.2% and 91.1% [20 ], and CEUS 87.0% and 83.0% [21 ]. However, our data was acquired on a preliminary examined group of 101 patients,
whereas the values of EU-TIRADS are derived from multicenter studies with more than
1000 patients. Therefore, a direct comparison should not be made yet, as V-flow has
to be proven in larger samples in the future.
This study has several potential limitations that should be taken into consideration.
Firstly, it employs a retrospective approach which may have inherent biases and limitations
in data collection. Additionally, the examination process itself was time-consuming,
which could impact the feasibility of implementing it in a clinical setting. Moreover,
it is important to note that V-flow is currently only available on high-end devices
(such as Mindray Resona 7 and Resona R9) equipped with special probe technology. Furthermore,
there is a lack of officially standardized protocols for V-flow procedures [9 ]. There is also no comparable literature addressing V-flow performed on thyroid nodules.
Another constraint is that the V-flow examination box or window can only be adjusted
horizontally and vertically but not diagonally. In addition, the examinations conducted
in this study were performed by just two experienced sonographers on a preliminary
examined group of patients. The number of 101 patients is adequate for a first trial.
However, the 8 included carcinomas do not cover the entire range of thyroid carcinomas
as follicular, anaplastic, poorly differentiated carcinomas, and metastases are missing.
Moreover, one in two medullary carcinomas was only detected because of high calcitonin
levels and turned out to be a 3mm microcarcinoma. In future iterations of V-flow technology,
the mode should also be improved to allow tracking of even very low velocity streams,
as the current minimal detectable velocity of V-flow is 23cm/s.
While some studies performed histological diagnostic workup with FNA or ultrasound-guided
biopsy [22 ]
[23 ], our study employed intra- or postoperative histopathological examinations, which
are considered equally accurate. It is important to emphasize that while V-flow and
multimodal sonographic imaging demonstrate high combined sensitivity and specificity,
only postoperative histopathology can consistently and accurately differentiate between
benign and malignant thyroid nodules [14 ]
[15 ].
Clinical relevance
V-flow visualizes microvascular perfusion, which indicates the status of a tumor
Malignant tumors are associated with slower and more turbulent microvascular hemodynamics
By including V-flow in the clinical ultrasound routine, the number of unnecessary
thyroid surgeries in cases of benign nodules can be reduced significantly
Always consider multiple ultrasound modes in the evaluation of suspicious thyroid
lesions and never rely on the findings of one sonographic technique
Adopting a comprehensive approach that incorporates various ultrasound modes can significantly
improve the accuracy of thyroid nodule assessment and play a pivotal role in guiding
appropriate clinical management and treatment decisions