Keywords
Pancreas - Endoscopic ultrasonography - Fine-needle aspiration/biopsy
Introduction
Endoscopic ultrasound-guided tissue acquisition (EUS-TA) is the recommended technique
for the sampling of solid pancreatic lesions. In recent decades, EUS-TA has evolved
owing to improvements in diagnostic sensitivity, such as needle size [1], sampling technique [2], use of different types of suction [3], and the employment of rapid on-site evaluation (ROSE) [4]. However, one of the major breakthroughs has been reached with the availability
of third-generation needles, which carry the design of end-cutting tips (e.g., Franseen
or fork-tip needles). The excellent diagnostic and histological yields over standard
fine-needle aspiration (FNA) [5]
[6] have shifted clinical practice from FNA to fine-needle biopsy (FNB).
Furthermore, the role of ROSE has been weighed [4] in favor of macroscopic on-site evaluation (MOSE). The MOSE of acquired tissue by
the endoscopist was first proposed by Iwashita et al, using an 19G FNA needle [7]. More recently, MOSE using end-cutting needles has been associated with high sample
adequacy, suggesting the possibility of replacing ROSE [8]
[9]. Finally, in the absence of ROSE, guidelines have recommended three to four needle
passes using an FNA needle and two to three passes using a reverse-bevel FNB needle.
However, the optimal number of needle passes performed using end-cutting needles for
the sampling of pancreatic solid lesions has not yet been established. In addition,
specifically designed studies aimed at determining the optimal number of needle passes
are lacking. A recent randomized study demonstrated that the adequacy (based on MOSE)
of samples collected with a Franseen needle was associated with a lower number of
needle passes compared with the conventional three passes [8]. Moreover, in a recent randomized study in which fork-tip needles were used, a minimal
incremental value of accuracy was observed with the second pass [6]. However, the study reported no further gain after adding a third pass. In contrast,
no data about the number of passes to be performed using a Franseen needle have been
published.
To fill this gap, we performed a prospective, multicenter study with the primary aim
of evaluating the diagnostic accuracy of FNB performed using a 22G Franseen needle
with one, two, and three needle passes. Secondary aims were specimen adequacy with
one, two, and three needle passes, reliability of MOSE to establish sample adequacy
at histology, factors impacting diagnostic accuracy, and the procedure-related adverse
events (AE) rate.
Patients and methods
Study design and patient population
This was a multicenter, prospective study conducted at 11 Italian centers. After local
ethics committee approval (protocol number HMD 487/22, June 14, 2022), the protocol
was registered on ClinicalTrials.gov (NCT05436704). Consecutive adult patients referred
for EUS-FNB for the diagnosis of solid pancreatic lesions were assessed for eligibility.
Exclusion criteria were: 1) previous biopsy of the lesion with a diagnosis of malignancy;
2) cystic component larger than 25% of volume; 3) uncorrectable coagulopathy or use
of anticoagulant that cannot be discontinued; 4) pregnancy or breast-feeding; and
5) lack of informed consent.
Procedures and specimens processing
All the procedures were performed after obtaining informed consent under deep sedation
or conscious sedation according to institutional policy. Only experienced endosonographers
with >400 EUS performed and not trained in cytopathology were involved. The needle
used for the study was the 22G Franseen needle (Acquire Boston Scientific; Natick,
Massachusetts, United States). The slow-pull technique was used in all cases: After
the needle tip was inserted into the target lesion, the stylet was slowly withdrawn
while several to-and-fro movements of the needle were performed [3]. The fanning technique was also used whenever possible [2]. As suggested by European Society of Gastrointestinal Endoscopy (ESGE) guidelines
[1], up to three needle passes were performed for each lesion.
The specimen collected after each needle pass was handled and inspected by the endosonographer
for MOSE evaluation. The worm-like whitish or yellowish material was aligned on a
slide using a syringe needle and the length was assessed using a ruler [8]. After MOSE, the whole sample (including bloody material and clots) was placed in
a labeled formalin-filled vial and processed independently as standard histology.
A dedicated pathologist with at least 5 years of experience in gastrointestinal pathology
at each participating site provided a diagnosis for each container and was not blinded
from the results of the previous sample.
Technical failure was defined when biopsy was not performed at all. Incomplete procedure
was defined when less than three passes were performed.
Definition and study endpoints
The primary endpoint was diagnostic accuracy of each sequential pass. Diagnostic accuracy
was defined as the percentage of lesion corresponding to the final diagnosis [10] that was assessed on surgical specimen. In non-resected patients, final diagnosis
was based on the evolution of the disease assessed for at least 6 months by a combination
of clinical course, imaging studies, and/or additional tissue sampling demonstrating
progression in cancer-related lesions or disease stability in the benign lesions [10]. Histologic evaluations followed the Papanicolaou classification [11]. EUS samples reported as suspicious for malignancy were considered as malignant
whereas those that contained inadequate material were included in the analysis and
considered as negative for malignancy. In addition, other performance measures (i.e.,
sensitivity and specificity) were evaluated for each needle pass.
Specimen adequacy was defined as the percentage of lesions sampled in which the obtained
material is representative of the target site and sufficient for diagnosis [10].
MOSE reliability was defined as the concordance rate between MOSE adequacy and presence
of histologic core (i.e., presence of a tissue sample that allows for histologic and
tissue architectural assessment) [10]. MOSE was defined as adequate if a macroscopic visible core (MVC) was obtained.
MVC was defined as worm-like whitish or yellowish material, not including fluid-like
specimens, measuring at least 10 mm in the major axis [8].
Potential factors impacting diagnostic accuracy, such as age, sex, lesion location
and size, biopsy route and number of needle passes, were evaluated.
AEs were evaluated according to the American Society for Gastrointestinal Endoscopy
workshop report [12].
Follow-up
After EUS-FNB, patients were observed in the recovery room for at least 2 hours and
were contacted at 24 hours and 14 and 30 days after the procedure to record any AEs.
Follow-up was performed by the study investigator at each participating center by
electronic chart review, outpatient visits, and telephone contacts. Follow-up was
terminated in case of surgical resection or death.
Statistical analysis
Sample size was calculated based on evaluation of the primary outcome of diagnostic
accuracy for evaluation of solid pancreatic lesions. The study hypothesis was that
the first needle pass was equivalent to the conventional three passes. A sample size
of 140 patients was required, based on the expected diagnostic accuracy of 96.7% after
three passes and 93.4% after one needle pass with a 22G FNB needle [6], an equivalence margin of ± 5%, power of 90%, and an alpha level of 5% (1-sided).
Considering an expected drop-out rate of 20%, we decided to enroll 170 patients.
Equivalence was met for the primary endpoint if the limits of a two-sided 90% confidence
interval (CI) excluded a difference between the two groups of more than 10%.
Continuous data were presented as mean and standard deviation whereas categorical
data were presented as numbers (percentages).
Normal distribution of variables was checked through Kolmogorov-Smirnov test.
Comparisons between paired groups were performed through McNemar’s test and P values were corrected through Bonferroni’s correction for multiple comparisons. Correlation
between adequacy rates of samples evaluated on MOSE and adequacy evaluated by means
of histology was performed by means of Cramer’s Φ test, where a Φ test between 0 and
0.3 represents weak correlation, between 0.3 and 0.6 moderate correlation, and between
0.6 and 1 strong correlation [13].
Correlation between baseline parameters and diagnostic accuracy was tested through
univariate logistic regression analysis and the results were expressed in terms of
odds ratio (OR) and 95% CIs.
All analyses were performed with rms package in R (R Foundation for Statistical Computing, Vienna, Austria).
Results
Patients
From July 2022 to October 2022, 170 consecutive patients (75 males, mean age 67.1
years) were enrolled and two were lost to follow-up. All patients underwent EUS-FNB
with three passes. Therefore, 168 patients were analyzed, and the per-protocol population
completely reflected an intention-to-treat analysis. The flow chart of the patients
recruited in this study is shown in [Fig. 1]. [Table 1] summarizes baseline features of the patient population.
Fig. 1 Study flow chart. EUS, endoscopic ultrasound.
Table 1 Baseline features of 168 patients analyzed.
|
Age, yr
Mean (SD)
|
67.1 (11.5)
|
|
*Other includes: Neuroendocrine carcinoma (2), autoimmune pancreatitis (1), intrapancreatic
spleen (1), lymphoid tissue (1), schwannoma (1)
SD, standard deviation; PDAC, pancreatic ductal adenocarcinoma; NET, neuroendocrine
tumor; CI, confidence interval.
|
|
Sex, N (%)
Male
Female
|
75 (44.7%)
93 (55.3%)
|
|
Tumor site, N (%)
Uncinate process
Head
Neck
Body
Tail
|
16 (9.5%)
75 (44.6%)
10 (6%)
40 (23.8%)
27 (16.1%)
|
|
Tumor size, mm
Mean (SD)
|
31.9 (12.2)
|
|
Biopsy route, N (%)
Transgastric
Transduodenal
|
84 (50.0%)
84 (50.0%)
|
|
Final diagnosis, N (%)
PDAC
NET
Metastasis
Inflammatory
Other*
|
127 (75.5%)
18 (10.7%)
12 (7.1%)
5 (3.2%)
6 (3.5%)
|
|
Follow-up
Median time, days (95% CI)
Surgical resection, N (%)
|
212 (168–254)
39 (23.2%)
|
Diagnostic accuracy
Diagnostic accuracy was 90.5% (95% CI 85.0%-94.1%) after one needle pass, 97.6% (95%
CI 94.1%-99.3%) after two passes, and 97.6% (95% CI 94.1%-99.3%) after three needle
passes, with 90.2% (95% CI 84.6%-94.3%), 97.5% (95% CI 93.8%-99.3%), and 97.5% (95%
CI 93.8%-99.3%) diagnostic sensitivity after one, two, and three needle passes, respectively.
Specificity was 100% in all study groups. No statistically significant difference
in terms of diagnostic accuracy was found between two and three passes (P=1.0), whereas both two and three passes significantly outperformed a single pass
(P=0.01). Per-pass analysis of diagnostic measures is reported in [Table 2].
Table 2 Diagnostic measures after one, two, and three needle passes observed in 168 patients
who underwent endoscopic ultrasound-guided fine-needle biopsy of solid pancreatic
lesions.
|
One pass
|
Two passes
|
Three passes
|
Two passes vs one pass
|
Three passes vs one pass
|
Three passes vs two passes
|
|
CI, confidence interval.
|
|
Sensitivity, % (95% CI)
|
90.2
(84.6–94.3)
|
97.5
(93.8–99.3)
|
97.5
(93.8–99.3)
|
P=0.009
|
P=0.009
|
p=1
|
|
Specificity, % (95% CI)
|
100
(94.3–100)
|
100
(93.4–100)
|
100
(93.4–100)
|
/
|
/
|
/
|
|
Accuracy, % (95% CI)
|
90.5
(85.0–94.1)
|
97.6
(94.1–99.3)
|
97.6
(94.1–99.3)
|
P=0.01
|
P=0.01
|
P=1
|
|
Adequacy, % (95% CI)
|
91.1
(85.7–94.9)
|
98.2
(95.8–99.3)
|
98.2
(95.8–99.3)
|
P=0.009
|
P=0.009
|
P=1
|
The difference in the accuracy between two or three passes and one pass was 7.1% (5%
to 9.2%). The lower limit of the CI for the difference in diagnostic accuracy exceeded
the equivalence margin of ±5%, therefore, equivalence was not shown for the primary
outcome.
Univariate regression analysis showed that only the number of passes was a significant
predictor of diagnostic accuracy (OR 4.3, 95% CI 1.4–13.2; P=0.01) ([Table 3]).
Table 3 Univariate analysis investigating factors associated with diagnostic accuracy.
|
Variable
|
Odds ratio
|
95% CI
|
P value
|
|
CI, confidence interval.
|
|
Age (ref. ≤67 years)
|
2.7
|
0.3–26.7
|
0.39
|
|
Sex (ref. female)
|
1.8
|
0.7–5.4
|
0.76
|
|
Location (ref. head/uncinate)
|
0.4
|
0.03–3.8
|
0.41
|
|
Size (ref. ≤30mm)
|
2.5
|
0.3–24.8
|
0.45
|
|
Biopsy route (ref. transgastric)
|
3.1
|
0.3–30.2
|
0.33
|
|
Number of passes (ref. one pass)
|
4.3
|
1.4–13.2
|
0.01
|
Secondary outcomes
Specimen adequacy rates were 91.1% (95% CI 85.7%-94.9%) after one needle pass, 98.2%
(95% CI 95.8%-99.3%) after two passes, and 98.2% (95% CI 95.8%-99.3%) after three
needle passes. Again, a significant difference was observed in the comparison between
three passes and one pass (P=0.009) and between two passes and one pass (P=0.009), whereas no difference was observed when comparing two vs three passes (P=1.0).
For MOSE reliability, 504 samples were evaluated and compared with histological assessment.
MOSE was deemed adequate in 473 of 504 cases (93.8%) with a concordance rate with
histology of 89.9% (453/504). Discordancy was observed in 25 of 31 cases deemed inadequate
and 26 of 473 cases recorded as adequate at MOSE and eventually resulted adequate
and inadequate at histology, respectively ([Table 4]). There was strong correlation between MOSE adequacy and adequacy assessed on histology
(Cramer’s Φ=0.63, P=0.007). The concordance between MOSE and histologic adequacy was 85.7%, 90.5%, and
93.5% after the first, second, and third passes, respectively.
Table 4 Concordance between macroscopic on-site evaluation adequacy and presence of histologic
core on 504 specimens collected during endoscopic ultrasound-guided fine-needle biopsy
of solid pancreatic lesions.
|
Histological evaluation
|
|
Adequate
|
Inadequate
|
Total
|
Concordance
|
Cramer’s Φ
|
P value
|
|
MOSE, macroscopic on-site evaluation
|
|
MOSE evaluation
|
Adequate
|
447
|
26
|
473
|
89.9%
|
0.63
|
0.007
|
|
Inadequate
|
25
|
6
|
31
|
|
Total
|
472
|
32
|
|
One case of mild acute pancreatitis (0.6%) was registered and managed conservatively
with 2 days of hospitalization. Moreover, 16 intraprocedural bleeding cases (9.5%)
were registered and considered as “incidents” for not requiring any medical intervention
nor prolongation of hospitalization. No cases of procedure-related death were observed.
Discussion
In recent years, EUS-FNB with end-cutting needles has revolutionized the practice
of EUS-TA of solid lesions. Major changes included the possibility of abandoning ROSE,
the retrieval of histological specimens for the diagnosis of rare conditions [14]
[15]
[16]
[17], and the reduction in needle passes. To this end, most endoscopists hold that, in
most cases, a sufficient sample for diagnosis is retrieved after the first pass using
an end-cutting needle. Indeed, a recent study by Bang et al reported that a single
pass of FNB with the Franseen needle could achieve a sensitivity of more than 90%
for diagnosis of pancreatic cancer [18]. However, ESGE guidelines suggest two to three passes with a reverse-bevel needle
[1] and a recent prospective study comparing two different end-cutting needles demonstrated
that at least two passes of FNB are required to achieve a diagnostic sensitivity of
90% in pancreatobiliary cancers [19]. Therefore, the number of passes is not yet standardized when an end-cutting needle
is used for sampling solid pancreatic lesions.
For this reason, we performed a multicenter prospective study assessing the diagnostic
accuracy of EUS-FNB after the first, second, and third needle pass using a Franseen
22G needle. We observed 90% accuracy after the first pass. This result can undoubtedly
be considered (by itself) an amazing achievement compared with the reported performance
of FNA. However, we found that the addition of a second pass significantly increased
the diagnostic accuracy to 97%. In contrast, the accuracy remained the same after
the third pass. The overall rate of accuracy reported in the present study agrees
with recent literature [4]
[5]
[6]
[20]
[21]
[22].
Our results reflect those of two randomized trials. In the first study, fork-tip needles
were compared with reverse-bevel needles; the fork-tip needle was reported having
93%, 97%, and 97% accuracy after one, two, and three needle passes, respectively [6]. In the second RCT, the Franseen needle was compared with a different end-cutting
needle with a three-prong asymmetric tip [19]. The authors found that the second pass improved the diagnostic sensitivity from
85.1% to 91.5% and from 82.4% to 90.2%, for the Franseen needle and the end-cutting
needle with a three-prong asymmetric tip, respectively [19]. Moreover, we tested the equivalence of one pass versus three passes (that in this
study reflect the comparison between one and two passes). Our hypothesis was not confirmed.
Indeed, the difference in accuracy proportion between two or three passes and one
pass was 7.1%, thus exceeding the equivalence margin of 5%.
The robustness of our findings was confirmed using univariate analysis investigating
factors associated with accuracy. We found that the number of passes was the only
variable significantly associated with accuracy with an OR of 4.3. Similar results
were observed when specimen adequacy was evaluated, with a significant improvement
from 91% to 98% by adding a second needle pass. Based on our findings, at least two
needle passes should be performed during EUS-FNB with end-cutting needles.
We also assessed the reliability of MOSE for establishing histologic adequacy. Overall,
504 passes were independently evaluated and MOSE results were compared with histological
evaluation. The rate of concordance was close to 90% with a Cramer Φ of 0.63, representing
a strong correlation. Overall, 51 of 504 specimens (10%) not concordant with histopathology
were observed. Interestingly, among 31 cases deemed inadequate with MOSE, 25 (80.6%)
were eventually adequate on histology. On the other hand, only 26 of 473 cases (5.5%)
evaluated as adequate with MOSE were deemed indequate on histology. This finding possibly
suggests that the adequacy cut-off of 10-mm white-yellowish core previously suggested
[23] and used in the study should be reassessed in specifically designed clinical trials.
Similar results were observed in a recent randomized trial comparing EUS-FNB driven
by MOSE and EUS-FNB with three passes [8] where 7% of discordant specimens were observed. Moreover, in the same study, the
addition of a second sample that was collected after MOSE adequacy to reach three
passes, as suggested by guidelines, improved the diagnostic adequacy and accuracy
from 90% to 95% and from 93% to 98%, respectively. However, in the aforementioned
study, both pancreatic and nonpancreatic lesions were included, and the number of
passes was established on MOSE. In contrast, the present study assessed the crude
association between MOSE and histology for each individual pass. Importantly, in the
present study, diagnostic accuracy was evaluated regardless of the MOSE results. MOSE
was compared with histologic adequacy that does not always reflect diagnostic accuracy.
Therefore, even if the concordance of MOSE and histologic adequacy was close to 90%
after the first pass, the present study demonstrated that a second pass should be
performed to increase diagnostic accuracy regardless of the result of MOSE after the
first pass.
Besides accuracy, EUS-FNB represents a tool to provide tissue for molecular tests
in the preoperative setting [24]. In a recent study, after the diagnosis was confirmed at ROSE, patients were randomized
to undergo EUS-FNB with two or three dedicated passes for DNA and RNA extraction from
paraffin blocks. Two passes performed similarly to three, with no significant difference
in the median concentration of DNA and RNA. Future studies should address whether
two passes only are sufficient for both diagnostic and molecular testing purposes.
Finally, our study confirms the excellent accuracy of EUS-FNB for the sampling of
pancreatic solid lesions performed with an end-cutting needle even in the absence
of ROSE. Our results support the data reported in a recent meta-analysis that highlighted
the non-superiority of EUS-FNB + ROSE over EUS-FNB with newer end-cutting needles
[19]. However, ROSE may still have a role when FNA needles are used.
Overall, the current data suggest sampling solid pancreatic lesions by performing
two needle passes. After the collection of samples with two passes, MOSE can be performed
where additional passes can be added in cases of MOSE inadequacy. This could shorten
the procedure time with significant advantages, especially for patients in poor general
condition.
Our study has several limitations. First, the designated pathologist at each center
evaluated all three specimens from each patient. Therefore, the evaluation of the
second sample could potentially be biased by the evaluation of the first specimen.
To overcome this, future studies should be specifically designed to compare samples
containing one pass with those containing two passes together. Second, only the 22G
Franseen needle with the slow-pull technique was used; thus, our result could be different
by using other devices or aspiration techniques. On the other hand, the performance
of Franseen needles was comparable to fork-tip ones, and both ranked the highest-performing
FNB needles in a recent large meta-analysis including 16 randomized controlled trials
[22]. Therefore, it is likely that these needles will become the most used in clinical
practice. Similarly, the slow-pull technique showed equal histologic and accuracy
rates compared with wet-suction for the evaluation of solid pancreatic lesions [3]
[21]. Third, MOSE reliability in terms of agreement with histological adequacy was evaluated
for each single pass; thus, it could be higher when two passes are performed together
and assessed macroscopically. Finally, we limited our study to solid pancreatic lesions
and no information was provided about extra-pancreatic masses.
Conclusions
In conclusion, the rates of accuracy and specimen adequacy with only one pass using
the 22G Franseen needle is remarkably high. Our study showed that the addition of
a second pass significantly increases the performance of EUS-FNB whereas a third pass
could be avoided. MOSE is a reliable tool to assess specimen adequacy and can be used
to evaluate the need for additional passes.