Introduction
The introduction of endoscopic ultrasound (EUS)-guided tissue acquisition represents
an important breakthrough in the field of endoscopy and has become an integral part
of the diagnostic and staging algorithms of various diseases of gastrointestinal tract
[1]. Traditionally, EUS-guided tissue sampling was performed with a fine-needle aspiration
(FNA) needle. However, the efficacy of EUS-FNA depends on multiple factors including
the characteristics of the target tissue [2] and the availability of an on-site cytopathologist [3]. To overcome these limitations of FNA needles, fine-needle biopsy (FNB) needles
were designed that allow sampling of core tissue from the target lesion.
Apart from needle type, the proper suction techniques may impact outcomes of EUS-guided
tissue acquisition. Various suction techniques used in tissue acquisition during EUS
include no suction (NS), dry suction (DS), stylet slow-pull (SSP), and wet suction
(WS). In the DS technique, a 10 ml pre-vacuum syringe is used after removal of stylet,
to generate a negative pressure for tissue acquisition. This improves the cellularity
of the sample but at the cost of blood contamination [4]. The SSP technique involves slow removal of the stylet during sampling to generate
negative pressure within needle, which is usually 5% of the force generated with standard
suction [5]. Lastly, the WS technique involves preflushing the needle with saline or heparin
prior to aspiration. Once the lesion has been punctured, a syringe prefilled with
saline is left attached to the proximal port and used later for aspiration [6].
In a recent meta-analysis [7], WS technique has been reported to have a higher cellularity compared to DS technique,
but comparable blood contamination and histological accuracy. With respect to DS versus
SSP, two meta-analyses have shown conflicting results [8]
[9]. In lieu of the heterogeneity of outcome from studies comparing the various methods
and dilemma regarding the optimal method of tissue acquisition during EUS, we conducted
a systemic review, pairwise meta-analysis and network meta-analysis (NMA) to compare
the various suction methods (NS, DS, WS, SSP) for EUS-guided tissue acquisition.
Methods
The present systematic review and network meta-analysis is reported as per the Preferred
Reporting Items for Systematic Reviews and Meta Analyses for Network Meta Analyses
(PRISMA NMA) guidelines [10] and registered with PROSPERO (CRD42022321181).
Information sources and search strategy
MEDLINE, Cochrane Central Register of Controlled Trials (CENTRAL), and Science Direct
were searched from 2010 to March 2022 for all relevant studies. A search was made
using the keywords: (EUS OR FNA OR FNB OR "Endoscopic ultrasound" OR "Fine needle
aspiration" OR "Fine needle biopsy") AND (Suction OR Stylet OR Wet OR "Slow-pull"
OR "Heparin"). In addition, the reference lists of all identified trials, guidelines,
and reviews on the topic were searched for relevant trials.
Study selection
The titles and abstracts of the retrieved search records were independently screened
by
two reviewers for inclusion and exclusion criteria, followed by full text examination
of
potential eligible citations. Any disagreement was resolved through discussion. Studies
included in this NMA were randomized controlled trials (RCTs) fulfilling the following
PICO
criteria: 1) Patients-EUS-guided tissue acquisition of solid lesions including pancreatic
lesion, lymph nodes and submucosal lesions; 2) Intervention-four suction techniques
which
include DS, WS, SSP and NS; 3) Comparison-Other suction techniques; and 3) Outcomes-adequacy
of sample, moderate to high cellularity, gross bloodiness and diagnostic accuracy.
Due to
non-standardization of evaluation of blood contamination and cellularity, outcome
variables
were defined according to the original protocol of each study. Single-arm studies,
studies
with sample size <10, conference abstracts and studies involving persons <18 years
of
age were excluded from the analysis.
Data extraction
Data extraction was performed independently by two investigators, and discrepancies
were resolved by a third reviewer. Data collection was done under the following headings:
study author and year, country, type of study, number of patients, types of intervention,
outcomes, and adverse events.
Risk of bias in individual studies and confidence in cumulative evidence
The risk of bias was assessed by two independent reviewers using the Cochrane risk-of-bias
tool for randomized trials (RoB 2). The assessment of the certainty of the evidence
for all evaluable outcomes, was done using the Confidence in Network Meta Analysis
(CINeMA) web application and the Grading of Recommendations Assessment, Development
and Evaluation (GRADE) approach for NMA.
Statistical analysis
Pairwise meta-analysis was performed using a random effect model in RevMan software
(version 5.4.1, Cochrane Collaboration). Dichotomous variables were analyzed using
the risk ratio and Mantel-Haenszel test. Network meta-analysis was performed using
Stata 17.0 software package (Stata Corp LP, College Station, Texas, United States)
and MetaInsight [Complex Review Support Unit (CRSU) network meta-analysis (NMA) web-based
app] using a Bayesian random effect model. The comparative efficacy of any two treatments
was modeled as a function of each treatment relative to the reference treatment (DS
in this study, as it is the most common method used). Treatment estimates were calculated
as odds ratios (ORs) for binary outcomes, along with their 95% confidence interval
(CI). The pooled ORs from the NMA were compared with corresponding ORs from a pairwise
meta-analysis of direct comparisons to assess the inconsistency between direct and
indirect comparisons. Wald test was performed to assess for global inconsistency.
Relative ranking of interventions for various outcomes was calculated as their surface
under the cumulative ranking (SUCRA). Publication bias was assessed by examining the
funnel plot asymmetry. The certainty or quality of evidence was evaluated based on
the GRADE (Grading of Recommendations, Assessment, Development and Evaluations) framework,
which is the most widely adopted tool for grading the quality of evidence and for
making recommendations.
Results
Study characteristics and risk of bias within studies
A total of 511 studies were identified from various databases and manual reference
searching. After removal of duplicate studies, 310 studies were screened out of which
27 were assessed for eligibility. Finally, 16 RCTs [11]
[12]
[13]
[14]
[15]
[16]
[17]
[18]
[19]
[20]
[21]
[22]
[23]
[24]
[25]
[26] with 2048 patients were included in the meta-analysis. [Fig. 1] shows the PRISMA diagram for study selection. [Table 1] summarizes the characteristics of the included studies. Eight studies were crossover
studies [11]
[15]
[17]
[19]
[20]
[21]
[22]
[23] while the rest eight were parallel studies [12]
[13]
[14]
[16]
[18]
[24]
[25]
[26]. Majority of the studies [13]
[14]
[15]
[16]
[17]
[18]
[19]
[20]
[22]
[24]
[25]
[26] included pancreatic lesions only, while 4 studies included extrapancreatic lesion
including lymph nodes and subepithelial lesions [11]
[12]
[21]
[23]. FNA needle was used in nine studies [11]
[12]
[13]
[14]
[16]
[17]
[21]
[23]
[26] among which seven studies used 22G needles [11]
[13]
[16]
[17]
[21]
[23]
[26] and two studies used other size needles [12]
[14]. Seven studies used FNB needle [15]
[18]
[19]
[20]
[22]
[24]
[25], among which only one study used 20G needles [18] and the rest used 22G needles. ROSE was available in only four studies [11]
[14]
[16]
[24]. The number of needle passes was two in the majority of the studies [11]
[12]
[15]
[17]
[19]
[20]
[21]
[23]. Six studies [15]
[16]
[20]
[23]
[24]
[25] had moderate risk of bias while 10 studies had low risk of bias [11]
[12]
[13]
[14]
[17]
[18]
[19]
[21]
[22]
[26] (Supplementary Fig. 1). The definitions of various outcomes used in the included studies in shown in Supplementary Table 1.
Fig. 1 PRISMA flowchart for study selection and inclusion process. From: Hutton B, Salanti G, Caldwell DM et al. The PRISMA extension statement for reporting of systematic reviews incorporating
network meta-analyses of health care interventions: checklist and explanations. Ann
Intern Med 2015; 162: 777–784.
Table 1 Characteristics of included randomized controlled trials.
Authors
|
Country
|
Study design
|
Total no. patients
|
Male/female
|
Mean age
|
Location of lesion
|
Needle used
|
ROSE
|
No. passes
|
Suction technique
|
No. patients in each arm
|
L/LN/P//O/SM, liver/lymph node/pancreatic mass/others/submucosal lesion; FNA, fine-needle
aspiration; FNB, fine-needle biopsy; DS/NS/SSP/WS, dry suction/no suction/slow stylet
pull/wet suction
|
Attam 2015 [11]
|
USA, Multicentric
|
Crossover
|
117
|
66/51
|
60.5±11.9
|
P63/LN35/L10/O9
|
22-G FNA
|
Yes
|
2
|
WS
|
117
|
DS
|
117
|
Bansal 2017 [12]
|
India, Single-center
|
Parallel
|
300
|
195/105
|
52±14
|
P65/LN235
|
19-G/22-G/25-G FNA
|
No
|
2
|
WS
|
100
|
DS
|
100
|
NS
|
100
|
Weston 2017 [13]
|
USA, Multicentric
|
Parallel
|
60
|
35/25
|
-
|
P60
|
22-G FNA
|
No
|
3
|
SSP
|
30
|
DS
|
30
|
Bang 2018 [14]
|
USA, Single-center
|
Parallel
|
352
|
191/161
|
68.3±12.4
|
P352
|
22-G/25-G FNA
|
Yes
|
2–8
|
DS
|
176
|
NS
|
176
|
Lee 2018 [15]
|
Korea, Multicentric
|
Crossover
|
50
|
27/23
|
66.8±12.6
|
P50
|
22-G FNB
|
No
|
2
|
SSP
|
50
|
DS
|
50
|
NS
|
50
|
Saxena 2018 [16]
|
USA, Multicentric
|
Parallel
|
121
|
70/51
|
64±13.8
|
P121
|
22-G FNA
|
Yes
|
1
|
SSP
|
61
|
DS
|
60
|
Cheng 2019 [17]
|
Brazil, Multicentric
|
Crossover
|
50
|
29/21
|
63.9±10.4
|
P50
|
22-G FNA
|
No
|
2
|
DS
|
50
|
SSP
|
50
|
Di Mitri 2019 [18]
|
Italy, Multicentric
|
Parallel
|
110
|
49/61
|
70.8±10.4
|
P110
|
20-G FNB
|
No
|
2–3
|
DS
|
55
|
SSP
|
55
|
Moreira 2020 [19]
|
Portugal, Single-center
|
Crossover
|
50
|
23/27
|
65.5±11.8
|
P50
|
22-G FNB
|
No
|
2
|
DS
|
50
|
NS
|
50
|
Tong 2020 [20]
|
China, Multicentric
|
Crossover
|
50
|
34/16
|
58.6±13.7
|
P50
|
22-G FNB
|
No
|
2
|
WS
|
50
|
DS
|
50
|
Wang 2020 [21]
|
China, Multicentric
|
Crossover
|
269
|
161/108
|
57.5±11.1
|
P161/LN108
|
22-G FNA
|
No
|
2
|
DS
|
269
|
WS
|
269
|
Bang 2020 [22]
|
USA, Single-center
|
Crossover
|
129
|
68/61
|
68.4±12.4
|
P129
|
22-G FNB
|
No
|
1
|
NS
|
129
|
SSP
|
129
|
DS
|
129
|
Takasumi 2021 [23]
|
Japan, Single-center
|
Crossover
|
26
|
16/10
|
63.6±16.1
|
SM26
|
22-G FNA
|
No
|
2
|
DS
|
26
|
WS
|
26
|
Ladd 2021 [24]
|
USA, Multicentric
|
Parallel
|
55
|
32/23
|
66.1±12.6
|
P55
|
22-G FNB
|
Yes
|
2–3
|
DS
|
20
|
WS
|
17
|
SSP
|
18
|
Zhou 2021 [25]
|
China
|
Parallel
|
116
|
78/38
|
58.9±9.7
|
P116
|
22-G FNB
|
No
|
1–5
|
DS
|
60
|
SSP
|
56
|
Paik 2021 [26]
|
Korea, Multicentric
|
Parallel
|
193
|
–
|
59.8±12.7
|
P193
|
22-G FNA
|
No
|
3
|
DS
|
94
|
NS
|
99
|
Direct meta-analysis
Dry suction vs. no suction
Five studies [12]
[14]
[15]
[19]
[26] reported data on DS vs. NS. DS was associated with better cellularity (4 RCTs;
OR=1.42, 95%CI [1.02–2.00]; I2=0.0%, P=0.81), but at
the cost of higher risk of gross bloodiness (4 RCTs; OR=1.92, 95%CI [1.31–2.81];
I2=0.0%, P=0.82). There was no difference between
DS and NS with respect to sample adequacy (4 RCTs; OR=1.49, 95%CI [0.53–4.18[;
I2=87%, P=0.000) or diagnostic accuracy (2 RCTs;
OR=0.96, 95%CI [0.63–1.45]; I2 =0.0%, P=0.37). There
was no difference in subgroups based on the location of lesion (Supplementary Fig. 2a), but on subgroup analysis based on needle type, DS was
associated with a higher sample adequacy with the use of FNB needle (Supplementary Fig. 2b).
Dry suction vs. wet suction
Six studies [11]
[12]
[20]
[21]
[23]
[24] compared the outcomes of DS vs. WS. There was no difference between DS and WS for
sample adequacy (6 RCTs; OR=0.60, 95%CI [0.27–1.34]; I2=72%, P=0.003), gross bloodiness (5 RCTs; OR=1.93, 95%CI [0.85–4.36];
I2=69%, P=0.01), moderate to highly cellular
sample (6 RCTs; OR=0.67, 95%CI [0.28–1.58]; I2=81%, P=0.000), and diagnostic accuracy (3 RCTs; OR=0.76, 95%CI [0.50–1.16];
I2=0.0%, P=0.92). There was no difference in
subgroups based on either the location of lesion (Supplementary Fig.
3a) or the type of the needle used (Supplementary Fig.
3b).
Dry suction vs. stylet slow-pull
Seven studies [13]
[15]
[16]
[17]
[22]
[24]
[25] reported data comparing DS vs. SSP. No significant difference was observed between
the two groups with respect to sample adequacy (5 RCTs; OR=0.95, 95%CI [0.45–1.99];
I2=44%, P=0.13), gross bloodiness (2 RCTs;
OR=1.19, 95%CI [0.32–4.45]; I2=0.0%, P=0.56),
moderate to highly cellular sample (5 RCTs; OR=0.88, 95%CI [0.38–2.05]; I2=70%,
P=0.009), and diagnostic accuracy (4 RCTs; OR=1.11, 95%CI
[0.57–2.16]; I2=21%, P=0.28) (Supplementary Fig. 4). There was no difference in subgroups based on the type of
the needle used.
Network meta-analysis
Adequacy of sample
Thirteen studies [11]
[12]
[13]
[14]
[15]
[16]
[19]
[20]
[21]
[23]
[24]
[25]
[26] reported data on sample adequacy from four interventions. There was no difference
between the various modalities on network estimate (Supplementary Table 2). Meta-regression was conducted taking the needle type into account as there was
significant difference between FNA and FNB on pairwise meta-analysis. On meta-regression,
there was no significant difference in ORs of adequacy when adjusted for either of
the needle types (Supplementary Fig. 5). As the direct meta-analysis did not show any significant difference based on location
of the lesion on subgroup analysis, meta-regression was not performed taking lesion
location into consideration.
A SUCRA plot was generated from the ranking plot. Ranking based on SUCRAs accounts
better for the uncertainty in the estimated treatment effects. WS was ranked first
(SUCRA 85.4) with the maximum probability of obtaining an adequate sample followed
by SSP (SUCRA 51.9), DS (SUCRA 46.4) and NS (SUCRA 16.3) ([Fig. 2]
a). The certainty of evidence for the SUCRA ranking was moderate.
Fig. 2 Radial surface under the cumulative ranking analysis (SUCRA) and network plot for
all the outcomes. a Sample adequacy. b Moderate to high cellularity. c Gross blood contamination. d Diagnostic accuracy. The number beside the suction techniques
indicate SUCRA values. DS, dry suction; NS, no suction; SSP, slow stylet pull; WS,
wet suction.
Moderate to high cellularity
Eleven studies [11]
[12]
[13]
[15]
[17]
[19]
[21]
[22]
[23]
[24]
[25] reported on the outcome of moderate to high cellularity. On network estimate, there
was no significant difference between the studies with respect to moderate to high
cellularity of sample (Supplementary Table 3). On meta-regression, there was no significant difference in ORs of cellularity when
adjusted for either of the needle types (Supplementary Fig. 6).
On SUCRA analysis, WS was ranked first (SUCRA 77.2) with the maximum probability of
obtaining a moderate to highly cellular sample followed by SSP (SUCRA 75.0), DS (SUCRA
37.8) and NS (SUCRA 10.1) ([Fig. 2]b). The certainty of evidence for the SUCRA ranking was moderate.
Gross bloodiness
Ten studies [11]
[12]
[14]
[15]
[17]
[18]
[19]
[20]
[21]
[24] reported data on gross bloodiness of sample from four interventions. On network
estimate, only WS had a significantly lower odds of gross bloodiness compared to DS
(OR=0.50, 95%CI [0.24–0.97]) (Supplementary Table 4).
Meta-regression was performed to study the effect of type of needle on bloodiness
of
sample. When adjusted for the effect of FNB needle, both WS (OR=0.35, 95%CI [0.13–0.85])
and NS (OR=0.38, 95%CI [0.15–0.92]) were better than DS with respect to gross bloodiness.
However, on adjusting for FNA needle, there was no difference between the interventions
on
network estimates ([Fig. 3]).
Fig. 3 Bayesian Forest plot for diagnostic accuracy. a Unadjusted. b Adjusted for the effect of FNB needle. c Adjusted for effect of FNA needle.
On SUCRA analysis, WS was ranked first (SUCRA 80.3) with the maximum probability of
obtaining an adequate sample followed by NS (SUCRA 77.5), SSP (SUCRA 23.6) and DS
(SUCRA 18.5) ([Fig. 2]
c). The certainty of evidence for the SUCRA ranking was moderate.
Diagnostic accuracy
Nine studies [14]
[15]
[17]
[18]
[19]
[20]
[21]
[23]
[25] reported data on diagnostic accuracy of sample from four interventions. On network
estimate, there was no significant difference between the studies with respect to
diagnostic accuracy (Supplementary Table 5). Meta-regression did not show any significant difference in ORs of adequacy when
adjusted for either of the needle types (Supplementary Fig. 7). On SUCRA analysis, WS was ranked first (SUCRA 80.2) with the maximum probability
of diagnostic accuracy followed by NS (SUCRA 45.0), DS (SUCRA 41.6) and SSP (SUCRA
33.1) ([Fig. 2]
d). The certainty of the evidence for the SUCRA ranking was low.
Publication bias, network coherence, sensitivity analysis and quality of evidence
There was no evidence of publication bias, which was assessed qualitatively based
on
the symmetry in the funnel plot for all the studies reporting various outcomes (Supplementary Fig. 8). The global Wald test for diagnostic accuracy
yielded a chi2 (0)=0.00, and the P value could not
be calculated, indicating incoherence or significant heterogeneity. There was no evidence
of network coherence for the other outcomes (Supplementary Table
6). Sensitivity analysis was conducted with exclusion of studies including
non-pancreatic lesions and exclusion of studies with available ROSE ([Table 2]) which did not show any change compared to overall analysis. The summary of
findings for treatment comparisons with quality of evidence based on the GRADE framework
is shown in Supplementary Table 7.
Table 2 Summary of findings with sensitivity analysis.
Techniques and outcomes
|
Odds ratio for overall analysis
|
Analysis of only pancreatic lesion
|
Exclusion of studies with ROSE
|
DS/NS/SSP/WS, dry suction/no suction/slow stylet pull/wet suction.
The table shows odds of an outcome with the first suction technique mentioned in each
row compared to the second technique.
|
Sample adequacy
|
DS vs. NS
|
1.45 (0.60–3.52)
|
1.00 (0.51–2.07)
|
1.65 (0.49–5.33)
|
DS vs. SSP
|
0.94 (0.36–2.51)
|
1.11 (0.56–2.28)
|
1.01 (0.23–4.39)
|
DS vs. WS
|
0.62 (0.26–1.49)
|
0.75 (0.15–3.72)
|
0.65 (0.18–2.36)
|
NS vs. SSP
|
0.64 (0.19–2.24)
|
1.11 (0.42–2.97)
|
1.64 (0.29–9.02)
|
NS vs. WS
|
0.42 (0.13–1.37)
|
0.73 (0.13–4.26)
|
0.39 (0.08–2.00)
|
SSP vs. WS
|
0.66 (0.19–2.25)
|
0.66 (0.12–3.81)
|
0.64 (0.09–4.47)
|
Moderate to high cellularity
|
DS vs. NS
|
1.47 (0.63–3.52)
|
1.68 (0.61–4.56)
|
1.44 (0.58–3.55)
|
DS vs. SSP
|
0.68 (0.33–1.72)
|
0.69 (0.30–1.69)
|
0.67 (0.26–1.79)
|
DS vs. WS
|
0.65 (0.35–1.29)
|
0.76 (0.15–3.68)
|
0.59 (0.22–1.61)
|
NS vs. SSP
|
0.46 (0.17–1.29)
|
0.41 (0.14–1.31)
|
0.47 (0.15–1.45)
|
NS vs. WS
|
0.44 (0.16–1.33)
|
0.45 (0.07–2.86)
|
0.41 (0.12–1.41)
|
SSP vs. WS
|
0.97 (0.33–2.91)
|
1.10 (0.20–5.68)
|
0.89 (0.22–3.37)
|
Gross bloodiness
|
DS vs. NS
|
1.85 (0.95–3.99)
|
1.91 (1.00–4.23)
|
2.06 (0.97–4.83)
|
DS vs. SSP
|
1.04 (0.53–2.03)
|
1.02 (0.50–2.11)
|
0.99 (0.43–2.18)
|
DS vs. WS
|
2.00 (1.03–4.14)
|
3.05 (0.96–9.35)
|
2.88 (1.33–6.13)
|
NS vs. SSP
|
0.56 (0.19–1.61)
|
0.53 (0.19–1.34)
|
0.48 (0.15–1.34)
|
NS vs. WS
|
1.08 (0.42–2.69)
|
1.59 (0.37–5.76)
|
1.39 (0.48–3.56)
|
SSP vs. WS
|
1.92 (0.65–5.77)
|
3.00 (0.77–10.83)
|
2.91 (0.96–8.90)
|
Diagnostic accuracy
|
DS vs. NS
|
0.99 (0.52–1.98)
|
1.00 (0.51–2.07)
|
1.40 (0.45–4.29)
|
DS vs. SSP
|
1.09 (0.57–2.19)
|
1.11 (0.56–2.28)
|
1.75 (0.73–4.23)
|
DS vs. WS
|
0.74 (0.37–1.43)
|
0.75 (0.15–3.72)
|
0.74 (0.38–1.42)
|
NS vs. SSP
|
1.10 (0.43–2.80)
|
1.11 (0.42–2.97)
|
1.24 (0.30–5.36)
|
NS vs. WS
|
0.74 (0.28–1.85)
|
0.73 (0.13–4.26)
|
0.53 (0.15–1.93)
|
SSP vs. WS
|
0.67 (0.25–1.67)
|
0.66 (0.12–3.81)
|
0.43 (0.14–1.26)
|
Discussion
EUS-guided tissue acquisition plays an essential role in diagnosing pathology related
to pancreatic masses and lymph nodes. Multiple suction techniques have been evaluated
to improve diagnostic adequacy and accuracy, which will, in turn, improve patient
outcomes. The present NMA showed no significant difference between the suction methods
concerning sample adequacy, moderate to high cellularity, and diagnostic accuracy.
WS was better compared to DS, with a lower odd of bloodiness. But this difference
was not significant when adjusting for the effect of the FNA needle on the outcome,
thus indicating a similar rate of gross blood contamination with various suction techniques
when using an FNB needle. Based on SUCRA, WS was ranked as the best suction method
for all the study outcomes.
A previous meta-analysis by Nakai et al. [8] reported that SSP was likely to provide lower blood contamination but similar cellularity
and diagnostic accuracy compared to DS. However, randomized trials, studies using
25G needle and studies involving pancreatic lesions showed higher diagnostic accuracy
with SSP than DS on sensitivity analysis. Capurso et al. [9] analyzed only RCTs and showed that SSP had similar adequacy and diagnostic accuracy
but a lower rate of blood contamination compared to DS. The present meta-analysis
did not show any significant difference between SSP and DS in pairwise and NMA. This
indicates the non-superiority of SSP over DS, although SSP may result in reduced blood
contamination. It may be because the force used in the aspiration may have led to
a higher amount of blood contamination with DS.
Ramai et al. [7] conducted a meta-analysis comparing WS and DS and showed higher specimen adequacy
with
WS (OR=3.18, 95%CI: [1.82–5.54]) but similar blood contamination and diagnostic accuracy
between the two methods. This is explained by the fact that a water column enhances
tissue
aspiration due to fluid dynamics and allows greater volumes of tissue to be aspirated
within a
given simulation time compared to a column of air [27]. The current NMA showed a lower risk of blood contamination with WS than with DS.
It
is possible that the presence of the saline solution eliminates the “empty space”
in the
needle lumen for the red blood cells to flow into, and thereby reduces the degree
of
bloodiness [11]. However, this superiority of WS is not seen on adjusting for the impact of the
FNA
needle. Thus, using either of the techniques with an FNB needle may not lead to a
difference
in the rate of blood contamination.
While WS was ranked first for accuracy based on SUCRA, a statistically significant
difference was not seen in different suction techniques. A variation in the definition
of outcomes and needle gauge could explain this finding. Compared to the 19G or 22G
needle, the 25G needle has high flexibility and a smaller diameter, making it easier
to handle [28]. Other studies have reported that a 20G ProCore needle has better diagnostic accuracy
and histological yield than a 25G needle [29]
[30]. European society of gastrointestinal endoscopy recommends using a 22-G or 25-G
needle due to unreliable results with other needles [31]. In their recent NMA, Han et al. concluded that FNB needles, particularly 22-G,
offer the highest diagnostic performance compared to FNA needles in sampling pancreatic
masses [32]. However, in another NMA, Facciorusso et al. [33] showed no difference in the diagnostic performance based on needle type (FNA vs.
FNB) or gauge (19G vs. 22G vs. 25G) for solid pancreatic lesions. Findings remained
similar in sensitivity analysis based on the availability of ROSE and the use of the
fanning technique.
In a recent NMA on the diagnostic performance of end-cutting FNB needles [34], Franseen needles and fork-tip needles outperformed reverse-bevel needles and FNA
needle for both sample adequacy and diagnostic accuracy. However, comparing FNB needle
size, 25G Franseen and 25G Fork-tip needles were not superior to 22G reverse-bevel
needles. Also, none of the FNB needles were superior when ROSE was available. Thus,
multiple factors can affect the final adequacy and accuracy of a sample obtained via
EUS-guided sampling.
The study's main strength is that we used NMA with rigorous methodology to analyze
various RCTs and previous meta-analyses, which included all types of suction methods
used during EUS tissue acquisition. Because we included only RCTs, we are able to
satisfy the condition of transitivity needed for NMA. Also, considering the various
sampling techniques practiced and two previous meta-analyses have shown conflicting
results with respect to DS versus SSP, this NMA helps clarify the choice for endoscopists.
There were a few limitations to the study, most of them inherent in any meta-analysis
and that warrant further discussion. First, the definitions of "blood contamination"
and "cellularity" were not uniform in all the studies. Hence, the results need to
be interpreted with caution. Second, the effect of the number of passes used during
EUS-guided tissue acquisition could not be analyzed, which may affect the sensitivity
of the tissue acquisition. Zhou et al. [25] demonstrated a significant increase in diagnostic accuracy with an increase in the
number of passes. After three passes with DS and four passes with SSP, there was no
further increase in diagnostic accuracy. However, most of the included studies in
this analysis used two passes which may have led to a suboptimal outcome. Third, there
was variation in the study design with half being crossover and half being parallel.
While the type of estimates was the same, they were derived using different techniques,
and especially the estimates of standard error were different. Fourth, there was a
slight difference in the size and type of the needle used. Among FNB needles, Franseen
needles and Fork-tip needles have been shown to be superior to reverse-bevel needles
and FNA needles for both sample adequacy and diagnostic accuracy [34]. This difference in needle type may contribute to the heterogeneity of outcomes.
Fifth, all studies did not describe whether they used the fanning technique or not.
Sixth, the location of lesions (solid pancreatic lesions, submucosal lesions, or lymph
nodes) may dictate the type of suction needed. Lastly, there was significant heterogeneity
in the NMA for the outcome of diagnostic accuracy.
Conclusions
To conclude, WS was associated with lower odds of bloodiness than DS and was ranked
as the best method for all the outcomes. However, there was a lack of sufficient literature
evidence to prove the unequivocal superiority of one suction technique over the other
during EUS-guided tissue acquisition. There is a need for development of standard
reporting guidelines for samples obtained using EUS. As the practice of EUS-guided
tissue acquisition has shifted toward increasing the use of FNB needles, there is
a need to study the effect of various suction techniques on tissue adequacy and diagnostic
accuracy using newer generation end-cutting needles.