Although self-expandable metallic stent (SEMS) deployment is a treatment option for
proximal malignant colonic obstructions, it remains a challenging procedure [1]
[2]
[3]. When the malignant colonic obstruction is close to the ileocecal valve, it is impossible
to maintain a 2.0 cm safety margin on the oral end of the SEMS [1]
[2]
[3]. This article describes the deployment of SEMS across the ileocecal valve in a patient
with acute malignant colonic obstruction.
A 71-year-old man with abdominal distension and pain was referred to our department.
Abdominal computed tomography revealed dilatation of the small intestine caused by
a tumor close to the ileocecal valve. Urgent SEMS deployment was carried out to decompress
the small intestine ([Video 1]), but maintaining the 2.0 cm safety margin at the oral end of the SEMS was impossible
([Fig. 1]). We then attempted to advance the guidewire across the ileocecal valve. In such
cases, the guidewire trajectory must be bent at 90° to pass through the ileocecal
valve. Therefore, we first advanced a bendable catheter (SwingTip; Olympus, Tokyo,
Japan) [4] with a long flexible-tip guidewire (0.025-inch, VisiGlide 2; Olympus, Tokyo, Japan).
However, the guidewire became coiled in the cecum [5]. We then used an ultra-hydrophilic coated guidewire (0.032-inch, Radifocus Guide
Wire M; Terumo, Tokyo, Japan), which was able to pass through the ileocecal valve
([Fig. 1 a]). Finally, we deployed two SEMSs (each 12 cm, Niti-S Enteral Colonic Uncovered Stent;
Taewoong Medical, Gimpo-si, South Korea) across the ileocecal valve under the guidewire
without any complication ([Fig. 1 b, c], [Fig. 2]). The patient underwent primary laparoscopic surgery 2 weeks after the intestinal
decompression.
Video 1 Deployment of self-expandable metallic stent across the ileocecal valve (ICV) in
a patient with acute malignant colonic obstruction (MCO).
Fig. 1 Self-expandable metallic stent (SEMS) deployment across the ileocecal valve. a Guidewire negotiation using a bendable catheter plus ultrahydrophilic coated guidewire.
The guidewire successfully passes the ileocecal valve and advances into the small
intestine. b Malignant colonic obstruction is close to the ileocecal valve and also appears to
invade the area around the ileocecal valve. As a result, the small intestine is distended.
c Colonic uncovered stents are successfully deployed across the ileocecal valve.
Fig. 2 Abdominal computed tomography (CT) following the day of the procedure. A CT scan
reveals self-expandable metallic stents deployed across the malignant colonic obstruction
and ileocecal valve. The edematous ileum/cecum and fluid collection indicates ischemic
changes due to acute malignant colonic obstruction.
A bendable catheter with an ultrahydrophilic coated guidewire facilitates the deployment
of SEMS across the ileocecal valve in patients when the malignant colonic obstruction
is close to the valve. This procedure enables primary laparoscopic surgery and prevents
the need for transnasal long intestinal tube insertion and secondary surgery after
decompression of the stoma.
Endoscopy_UCTN_Code_CCL_1AC_2AD
Endoscopy E-Videos is an open access online section, reporting on interesting cases and new techniques
in gastroenterological endoscopy. All papers include a high quality video and all
contributions are freely accessible online. Processing charges apply (currently EUR
375), discounts and wavers acc. to HINARI are available.
This section has its own submission website at https://mc.manuscriptcentral.com/e-videos