Endoscopic ultrasound (EUS)-guided therapy of gastric varices, first reported as the
use of a cyanoacrylate (CYA) injection [1 ], now includes the deployment of coils without CYA [2 ] and the combined method, involving deployment of one to two coils followed by an
injection of CYA [3 ]. Regardless of the method used, EUS-guided therapy of gastric varices is increasingly
performed because of its safety profile and accuracy. EUS-guided angiography can be
used to assess fluidodynamics, the anatomy of gastric varices, and gastrorenal shunt
(GRS) patency.
We present some of our findings after EUS-guided angiography, injecting hydrosoluble
or liposoluble contrast through 19-gauge needles in the perforating feeding vein,
during EUS-guided therapy of gastric varices with coil deployment only ([Fig. 1 ]). [Video 1 ] shows four examples of our findings. Case A shows high blood flow clearing the contrast
immediately. Case B shows the contrast flowing through five coils towards the GRS
and the inferior vena cava (IVC). Case C shows the liposoluble contrast (Lipiodol)
seeming to be retained after deploying sixteen coils but some droplets passing to
the GRS and the IVC. Case D shows the passage of contrast through five coils towards
the GRS and IVC.
Fig. 1 Angiographic images showing: a hydrosoluble contrast media passing through five coils and displaying a huge gastrorenal
shunt (GRS; arrows); b the fluidodynamic behavior of the hydrosoluble contrast media flowing through the
five coils towards the GRS and the inferior vena cava (arrows).
Video 1 Anatomic and hemodynamic findings during endoscopic ultrasound-guided angiography
of gastric varices.
In all of these cases, gastric variceal obliteration was achieved. These findings
could explain the results of two studies that used CYA mixed with Lipiodol and performed
a chest computed tomography scan after the EUS-guided procedure [4 ]
[5 ]. One study found a 47 % rate of asymptomatic pulmonary glue embolism after EUS-guided
injection of CYA [4 ]. The other study, which compared endoscopic injection of CYA with the EUS-guided
combined technique (coil + CYA), found asymptomatic pulmonary glue embolism in 50 %
and 25 % of patients, respectively [5 ].
The rationale for the use of CYA after deploying coils is that the glue is trapped
by the coils. However, some studies [4 ]
[5 ] and the cases shown in [Video 1 ] raise a note of caution on the use of CYA. EUS-guided angiography evaluates fluidodynamic
behavior of hydrosoluble/liposoluble contrasts, providing an insight into the behavior
of any substance injected in such large, high flow blood vessels, even when multiple
coils have previously been deployed, and would be helpful if EUS-guided therapy is
considered. Therefore, we prefer to deploy as many coils as needed to obtain a thick
mesh and leave them time to obstruct the blood flow, so avoiding any potential adverse
events associated with the use of CYA.
Endoscopy_UCTN_Code_TTT_1AS_2AC
Endoscopy E-Videos is an open access online section, reporting on interesting cases and new techniques
in gastroenterological endoscopy. All papers include a high quality video and all
contributions are freely accessible online. Processing charges apply (currently EUR
375), discounts and wavers acc. to HINARI are available.
This section has its own submission website at
https://mc.manuscriptcentral.com/e-videos