Cardiac vector flow imaging

 

Kristoffer Lindskov Hansen1, 2

1 Department of Diagnostic Radiology, Copenhagen University Hospital, Copenhagen, Denmark
2 Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark

Imaging of the cardiovascular flow is an integrated part of the cardiac exam in patients with congenital and acquired cardiac conditions. The conventional imaging methods are ultrasound, computed tomography, angiography, and magnetic resonance imaging. While ultrasound is cheap, mobile, real-time, and safe, the ultrasound mode used for flow assessment, Doppler ultrasound, is limited by angle dependency [1]. This implies that only flow in the direction of the ultrasound beam is evaluated. Vector flow imaging is a new real-time ultrasound method for angle independent flow assessment introduced by Jensen et al. [2]. The first studies of cardiac vector flow imaging have been conducted using a commercial ultrasound platform with a linear array transducer ([Fig. 1]), and the studies revealed that cardiac vector flow imaging is possible and useful [3].

Zoom Image
Fig. 1 Vector flow imaging of the ascending aorta in longitudinal (left image) and transverse scan plane (right image) acquired intraoperatively. The real-time vector velocities are displayed as colored pixels on the B-mode image. The colors given by a 2D color bar define flow direction and velocity magnitude, and the superimposed vector arrows facilitate the flow interpretation.

The initial studies concerned feasibility of the method when applied intraoperatively in patients with normal and diseased aortic valve [4] [5], while the following studies explored advantages, limitations and possible applications of the method when applied intraoperatively on patients scheduled for cardiac by-pass surgery and aortic valve implantation [6] [7] [8] [9] [10]. Examples of vector flow imaging have been reported of blood flow in the normal and the congenital diseased pediatric heart using transthoracic ultrasound [11].

Among the findings were shown that the aortic secondary flow consists of a systolic and diastolic component both related to the primary antegrade flow and aortic valve stenosis [6] [7], that atherosclerotic plaques have a predilection for vessel locations with altered flow [7], that flow complexity of the primary antegrade flow of the ascending aorta is related to aortic valve stenosis [6], and that congenital heart defects alter the flow direction in the ventricles [11].

It is indicated that cardiac vector flow imaging can provide visualization of the complex flow patterns within the heart and great vessels, that conventional as well as new flow measures can be obtained with vector flow imaging, and that new information of normal and altered flow can be gained with vector flow imaging in healthy persons, in patients with congenital heart defects, and in patients with acquired cardiovascular diseases. Cardiac vector flow imaging may become a powerful tool for cardiovascular flow assessment.


#

Publication History

Publication Date:
05 October 2020 (online)

© 2020. Thieme. All rights reserved.

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany


Zoom Image
Fig. 1 Vector flow imaging of the ascending aorta in longitudinal (left image) and transverse scan plane (right image) acquired intraoperatively. The real-time vector velocities are displayed as colored pixels on the B-mode image. The colors given by a 2D color bar define flow direction and velocity magnitude, and the superimposed vector arrows facilitate the flow interpretation.