Endoscopy 2020; 52(12): E454-E455
DOI: 10.1055/a-1164-7972
E-Videos

The screw tip stent retriever for biliary drainage in a severe living donor liver transplant anastomotic stricture

Abdul Kouanda
Department of Medicine, University of California, San Francisco, California, United States
,
Patrick Avila
Department of Medicine, University of California, San Francisco, California, United States
,
Mustafa Arain
Department of Medicine, University of California, San Francisco, California, United States
› Author Affiliations
 

The screw tip stent retriever (STSR) is an endoscopic device that allows for removal of biliary and pancreatic duct stents while maintaining guidewire placement. A few case reports of patients with biliary strictures in whom standard dilation techniques have failed have described success of the STSR for dilating and traversing high grade benign and malignant strictures [1] [2] [3]. In this video case report ([Video 1]), we show that it can also be used in living donor liver transplant (LDLT) recipients with high grade strictures and relatively small upstream intrahepatic bile ducts.

Video 1 Use of the screw tip stent retriever to traverse a high grade biliary anastomotic stricture in a living donor liver transplant recipient.


Quality:

The patient was a 62-year-old woman who presented with elevated liver tests 3 years after left lobe LDLT. Subsequent magnetic resonance cholangiopancreatography showed a biliary anastomotic stricture and mild intrahepatic biliary dilatation ([Fig. 1 a]). A cholangiogram obtained through endoscopic retrograde cholangiopancreatography (ERCP) revealed near complete obstruction at the level of the surgical anastomosis ([Fig. 1 b]). A 0.018-inch guidewire was able to traverse the stricture; however, neither the CannulaTome (Cook Medical, Bloomington, Indiana, USA) nor a tapered tip cannula could pass. An 8.5-Fr STSR was then used to advance across the stricture by applying gentle pressure and clockwise torque ([Video 1]), which then allowed for balloon dilation and placement of a 10 mm × 6 cm fully covered metal stent. A 10 Fr × 20 cm plastic stent was deployed within the metal stent to reduce migration risk ([Fig. 2 a]). No adverse events occurred.

Zoom Image
Fig. 1 Imaging studies of anastomotic stricture. a Magnetic resonance cholangiopancreatography demonstrating high grade stricture (arrow). b Fluoroscopic appearance of the stricture on endoscopic retrograde cholangiopancreatography.
Zoom Image
Fig. 2 Endoscopic retrograde cholangiopancreatography (ERCP) images. a A 10 mm × 6 cm fully covered metal stent was deployed across the anastomosis with the distal end within the native bile duct. A 10 Fr × 20 cm plastic stent was subsequently placed through the metal stent to reduce migration risk. b Follow-up ERCP 3 months later showed resolution of the biliary stricture after removal of the previously placed stents.

Liver tests returned to normal and follow-up ERCP 3 months later showed stricture resolution ([Fig. 2 b]). The patient is now at 2.5 years of follow-up and continues to have normal liver tests.

In conclusion, the STSR can be an effective tool for traversing and dilating high grade anastomotic strictures in LDLT recipients, thereby avoiding percutaneous drainage or surgical revision.

Endoscopy_UCTN_Code_TTT_1AR_2AG

Endoscopy E-Videos
https://eref.thieme.de/e-videos

Endoscopy E-Videos is a free access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high
quality video and all contributions are
freely accessible online.

This section has its own submission
website at
https://mc.manuscriptcentral.com/e-videos


#

Competing interests

Dr. Arain is a consultant for Olympus, Boston Scientific, and Medtronic. Drs. Kouanda and Avila declare that they have no conflict of interest.

  • References

  • 1 Mohamed E, Kröner PT, Kumar U. et al. Use of a Soehendra stent retriever in dilation of an anastomotic biliary stricture in a post-liver transplant patient. Endoscopy 2016; 8 (Suppl. 01) E35-E36
  • 2 Faigel DO, Ginsberg GG, Kochman ML. Innovative use of the Soehendra stent retriever for biliary stricture recannalization. Gastrointest Endosc 1996; 44: 635
  • 3 Vida F, Ball TJ, Kozarek RA. et al. New application for the Soehendra stent retriever. Gastrointest Endosc 1998; 47: 9-10

Corresponding author

Abdul Kouanda, MD
Department of Gastroenterology and Hepatology
University of California
513 Parnassus Avenue
San Francisco, CA 94143
United States   
Fax: +1-415-476-0659   

Publication History

Article published online:
12 May 2020

© 2020. Thieme. All rights reserved.

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany

  • References

  • 1 Mohamed E, Kröner PT, Kumar U. et al. Use of a Soehendra stent retriever in dilation of an anastomotic biliary stricture in a post-liver transplant patient. Endoscopy 2016; 8 (Suppl. 01) E35-E36
  • 2 Faigel DO, Ginsberg GG, Kochman ML. Innovative use of the Soehendra stent retriever for biliary stricture recannalization. Gastrointest Endosc 1996; 44: 635
  • 3 Vida F, Ball TJ, Kozarek RA. et al. New application for the Soehendra stent retriever. Gastrointest Endosc 1998; 47: 9-10

Zoom Image
Fig. 1 Imaging studies of anastomotic stricture. a Magnetic resonance cholangiopancreatography demonstrating high grade stricture (arrow). b Fluoroscopic appearance of the stricture on endoscopic retrograde cholangiopancreatography.
Zoom Image
Fig. 2 Endoscopic retrograde cholangiopancreatography (ERCP) images. a A 10 mm × 6 cm fully covered metal stent was deployed across the anastomosis with the distal end within the native bile duct. A 10 Fr × 20 cm plastic stent was subsequently placed through the metal stent to reduce migration risk. b Follow-up ERCP 3 months later showed resolution of the biliary stricture after removal of the previously placed stents.