Endoscopy 2018; 50(09): E254-E255
DOI: 10.1055/a-0624-1609
E-Videos
© Georg Thieme Verlag KG Stuttgart · New York

Endoscopic ultrasound-guided transrectal pelvic abscess drainage using a lumen-apposing metal stent

Shawn L. Shah
1   Division of Gastroenterology and Hepatology, New York-Presbyterian/Weill Cornell Medical Center, New York, New York, USA
,
Salem Karadesh
1   Division of Gastroenterology and Hepatology, New York-Presbyterian/Weill Cornell Medical Center, New York, New York, USA
,
Enad Dawod
1   Division of Gastroenterology and Hepatology, New York-Presbyterian/Weill Cornell Medical Center, New York, New York, USA
,
Monica Saumoy
1   Division of Gastroenterology and Hepatology, New York-Presbyterian/Weill Cornell Medical Center, New York, New York, USA
,
Cheguevara Afaneh
2   Department of Surgery, New York-Presbyterian/Weill Cornell Medical Center, New York, New York, USA
,
Reem Z. Sharaiha
1   Division of Gastroenterology and Hepatology, New York-Presbyterian/Weill Cornell Medical Center, New York, New York, USA
› Author Affiliations
Further Information

Corresponding author

Reem Z. Sharaiha, MD, MSc
1305 York Ave, 4th Floor
New York
NY, 10065
USA   

Publication History

Publication Date:
28 June 2018 (online)

 

A 31-year-old woman with asthma presented with 1 week of lower abdominal pain and fevers after a recent emergency room discharge for appendicitis that had been managed conservatively with antibiotics. Upon presentation, she underwent a computed tomography (CT) scan of the abdomen and pelvis, which revealed a multiloculated pelvic abscess measuring approximately 7.3 × 4.7 × 7.0 cm ([Fig. 1]). The collection was thought to be unamenable to drainage by interventional radiology.

Zoom Image
Fig. 1 Computed tomography scan of the abdomen and pelvis showing a multiloculated pelvic abscess measuring approximately 7.3 × 4.7 × 7.0 cm.

The patient underwent a lower gastrointestinal endoscopic ultrasound (EUS), which identified the pelvic abscess from the rectosigmoid colon. After color flow Doppler had been used to ensure there was no intervening vasculature, a cautery-enhanced delivery system was used to deploy a 10-mm lumen-apposing metal stent (LAMS; Axios; Boston Scientific, Marlborough, Massachusetts, USA) into the collection, with the distal flange in the collection and the proximal end in the sigmoid colon. This process was visualized under fluoroscopic, endosonographic, and endoscopic guidance. Copious amounts of purulent material were seen draining from the stent. The stent was then dilated and two double-pigtail plastic stents (10 Fr × 7 cm) were deployed into the metal stent to prevent migration ([Video 1]).

Video 1 Endoscopic ultrasound-guided transrectal abscess drainage using a lumen-apposing metal stent (LAMS).


Quality:

The patient was discharged on hospital day 4 after an uncomplicated post-operative course. A repeat CT scan of the abdomen and pelvis was performed nearly 3 weeks later and revealed resolution of the multiloculated pelvic abscess; the LAMS was endoscopically removed a few days later. The patient was subsequently seen in follow-up and has continued to remain asymptomatic.

The use of LAMSs has revolutionized EUS as it creates a large conduit for drainage, as well as for passage of both the endoscope and a variety of endoscopic accessories [1]. While surgical resection has been the main approach to drainage of intra-abdominal and pelvic collections, EUS can be a useful modality to aid in the diagnosis and for therapeutic drainage of pelvic collections [2] [3] [4] [5].

Endoscopy_UCTN_Code_TTT_1AS_2AZ

Endoscopy E-Videos
https://eref.thieme.de/e-videos

Endoscopy E-Videos is a free access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high quality video and all contributions are freely accessible online.
This section has its own submission website at https://mc.manuscriptcentral.com/e-videos


#

Competing interests

Reem Z. Sharaiha is a consultant for Boston Scientific and Apollo Endosurgery.

  • References

  • 1 Hammad T, Khan MA, Alastal Y. et al. Efficacy and safety of lumen-apposing metal stents in management of pancreatic fluid collections: are they better than plastic stents? A systematic review and meta-analysis. Dig Dis Sci 2018; 63: 289-301
  • 2 Donatelli G, Dumont JL, Cereatti F. et al. EUS-guided transrectal evacuation of organized pelvic collection following Roux-en-Y gastric bypass after failure of radiological and surgical approach. Obes Surg 2018; 28: 595-596
  • 3 Kawakami H, Kuwatani M, Kawahata S. et al. Endoscopic ultrasound-guided pelvic abscess drainage using a dedicated, wide, flared-end, fully covered self-expandable metal stent. Endoscopy 2015; 47 (Suppl. 01) E265-E266
  • 4 Luigiano C, Togliani T, Cennamo V. et al. Transrectal endoscopic ultrasound-guided drainage of pelvic abscess with placement of a fully covered self-expandable metal stent. Endoscopy 2013; 45 (Suppl. 02) E245-E246
  • 5 Poincloux L, Caillol F, Allimant C. et al. Long-term outcome of endoscopic ultrasound-guided pelvic abscess drainage: a two-center series. Endoscopy 2017; 49: 484-490

Corresponding author

Reem Z. Sharaiha, MD, MSc
1305 York Ave, 4th Floor
New York
NY, 10065
USA   

  • References

  • 1 Hammad T, Khan MA, Alastal Y. et al. Efficacy and safety of lumen-apposing metal stents in management of pancreatic fluid collections: are they better than plastic stents? A systematic review and meta-analysis. Dig Dis Sci 2018; 63: 289-301
  • 2 Donatelli G, Dumont JL, Cereatti F. et al. EUS-guided transrectal evacuation of organized pelvic collection following Roux-en-Y gastric bypass after failure of radiological and surgical approach. Obes Surg 2018; 28: 595-596
  • 3 Kawakami H, Kuwatani M, Kawahata S. et al. Endoscopic ultrasound-guided pelvic abscess drainage using a dedicated, wide, flared-end, fully covered self-expandable metal stent. Endoscopy 2015; 47 (Suppl. 01) E265-E266
  • 4 Luigiano C, Togliani T, Cennamo V. et al. Transrectal endoscopic ultrasound-guided drainage of pelvic abscess with placement of a fully covered self-expandable metal stent. Endoscopy 2013; 45 (Suppl. 02) E245-E246
  • 5 Poincloux L, Caillol F, Allimant C. et al. Long-term outcome of endoscopic ultrasound-guided pelvic abscess drainage: a two-center series. Endoscopy 2017; 49: 484-490

Zoom Image
Fig. 1 Computed tomography scan of the abdomen and pelvis showing a multiloculated pelvic abscess measuring approximately 7.3 × 4.7 × 7.0 cm.