Summary
Introduction: Otoacoustic emissions can be an alternative for cochlear evaluation in noise induced hearing loss (NIHL).
Objective: To investigate the correlation between the findings of audiometry results and distortion product otoacoustic emissions (DPOAE) in the military police.
Method: from cross-sectional and retrospective study, 200 military police officers were submitted to audiological evaluation - pure tone audiometry and DPOAE.
Results: considering the provisions of Ordinance 19 of the Labour Department, the results were suggestive of induced hearing loss by high sound pressure levels in 58 individuals, distributed as follows: 28 (48.3%) bilateral cases and 30 (51.7%) unilateral cases, and 15 (25.85%) in each ear. The correlation between the audiometric and DPOAE showed statistical significance in most of the frequencies tested in both ears, confirming that the greater the degree of hearing loss, the smaller the DPOAE amplitudes. In addition, there was observed significant difference between the DPOAEs amplitudes of normal subjects and listeners with hearing loss, confirming the lowering of responses in the group with hearing loss.
Conclusion: considering that the correlation between pure tone audiometry and DPOAE, we conclude that otoacoustic emissions can be a complementary tool for the detection and control of NIHL in military police.
Resumo
Introdução: As emissões otoacústicas podem ser uma alternativa para avaliação coclear na perda auditiva induzida por ruído (PAIR).
Objetivo: verificar a correlação entre os achados da audiometria tonal e os resultados das emissões otoacústicas produto de distorção (EOAPD) em policiais militares.
Método: a partir de estudo transversal e retrospectivo, 200 policiais militares foram submetidos à avaliação audiológica - audiometria tonal liminar e EOAPD.
Resultados: considerando o disposto na Portaria 19 do Ministério do Trabalho, os resultados foram sugestivos de perda auditiva induzida por níveis de pressão sonora elevados em 58 indivíduos, distribuídos da seguinte forma: 28 (48,3%) casos bilaterais e 30 (51,7%) casos unilaterais, sendo 15 (25,85%) em cada orelha. A análise de correlação entre a audiometria e as EOAPD, demonstrou significância estatística na maior parte das frequências testadas, em ambas as orelhas, confirmando que quanto maior o grau de perda auditiva, menor a amplitude das EOAPD. Além disso, foi observada existência de diferença significativa das amplitudes das EOAPD entre indivíduos normo ouvintes e portadores de perda auditiva, confirmando o rebaixamento das respostas no grupo com perda da audição.
Conclusão: considerando que houve correlação entre a audiometria e o teste de EOAPD, concluímos que as emissões otoacústicas podem ser uma ferramenta complementar, para a detecção e controle de PAIR em policias militares.
-
Bibliographical References
- 1 Brasil. Ministério do Trabalho. Portaria n° 3214, 08 de julho de1978; NR 15. Atividades e operações insalubres. DOU, 06 de julho de 1978.
- 2 Guida HL, Kinoshita SK. Quantificação dos níveis de ruído no estande de tiros da polícia militar / Marília - SP. Em: Anais do 23° Encontro Internacional de Audiologia; 2008, 12 15 março; Itajaí, Brasil. Itajaí: Academia Brasileira de Audiologia, 2008. p.1440.
- 3 Brasil. Ministério da Justiça do Brasil. Segurança Pública, estatística. [citado em 2011 ago 01]. Disponível em: http://portal.mj.gov.br/data/Pages/MJCF2BAE97ITEMIDAAC CEEFBA784458E99DCADBC672C3096PTBRIE.htm
- 4 Comitê Nacional de Ruído e Conservação Auditiva. Perda auditiva induzida pelo ruído relacionado ao trabalho. Acta Awho 1994; 13 (3) 126-7
- 5 Teles RM, Medeiros MPH. Perfil audiométrico de trabalhadores do distrito industrial de Maracanaú-CE. Rev Soc Bras Fonoaudiol 2007; 12 (3) 233-9
- 6 Harger MRHC, Barbosa-Branco A. Efeitos auditivos decorrentes da exposição ocupacional ao ruído em trabalhadores de marmoraria do Distrito Federal. Rev Ass Med Bras 2004; 50 (4) 396-99
- 7 Flamme G, Wong A, Liebe K, Lynd J. Estimates of auditory risk from outdoor impulse noise II: civilian firearms. Noise Health 2009; 11 (45) 231-42
- 8 Silva AP, Costa EA, Rodrigues SMM, Souza HLR, Massafera VG. Avaliação do perfil auditivo de militares de um quartel do Exército Brasileiro. Rev Bras Otorrinolaringol 2004; 70 (3) 344-50
- 9 Glorig A. Noise: past, present and future. Ear Hear 1980; 1: 4-18
- 10 Marshall L, Miller JAL, Heller LM, Wolgemuth KS, Hughes LM, Smith SD, Kopke RD. Detecting incipient inner-ear damage from impulse noise with otoacoustic emissions. J Acoust Soc Am 2009; 125 (2) 995-1013
- 11 Kós MI, Almeida K, Frota S, Hoshino ACH. Emissões otoacústicas produto de distorção em normo ouvintes e em perdas auditivas neurossensoriais leve e moderada com os protocolos 65/55 dBNPS e 70/70 dBNPS. Rev Cefac 2009; 11 (3) 465-72
- 12 Gattaz G, Wazen SRG. O registro das emissões otoacústicas evocadas - produto de distorção em pacientes com perda auditiva induzida pelo ruído. Rev Bras Otorrinolaringol 2001; 67 (2) 213-18
- 13 Job A, Raynal M, Kossowski M, Studler M, Ghernaouti C, Baffioni-Venturi A, Roux A, Darolles C, Guelorget A. Otoacoustic detection of risk of early hearing loss in ears with normal audiograms: a 3. year follow-up study. Hear Ear 2009; 251 (1) 10-16
- 14 Marques FP, Costa EA. Exposição ao ruído ocupacional: alteração no exame de emissões otoacústicas. Rev Bras Otorrinolaringol 2006; 72 (3) 362-6
- 15 Fukuda C, Munhoz MSL, Toledo FB, El Hassan S. Emissões otoacústicas por produto de distorção em trabalhadores expostos a ruído. Acta Awho 1998; 17 (4) 176-85
- 16 Konopka W, Olszewski J, Pietkiewicz P, Mielczarek M. Distortion product otoacoustic emissions before and after one year exposure to impulse noise. Otolaryngol Pol 2006; 60 (2) 243-47
- 17 Guida HL, Morini RG, Cardoso ACV. Avaliação audiológica e de emissões otoacústicas em indivíduos expostos a ruído e praguicidas. Arq Int Otorrinolaringol 2009; 13 (3) 264-9
- 18 Atchariyasathian V, Chayarpham S, Saekhow S. Evaluation of noise-induced hearing loss with audiometer and distortion product otoacustic emissions. J Med Assoc Thai 2008; 91 (7) 1066-71
- 19 Coelho MSB, Ferraz JRS, Almeida EOC, Almeida Filho N. As emissões otoacústicas no diagnóstico diferencial das perdas auditivas induzidas por ruído. Rev Cefac 2010; 12 (6) ): 1050-58
- 20 Santos TMM, Russo ICP. A prática da audiologia clínica. 5a ed. São Paulo: Cortez Editora; 2005
- 21 Brasil. Ministério do Trabalho. Portaria n° 19 GM/SSSTb, de 9 de abril de 1998. Estabelece diretrizes e parâmetros mínimos para avaliação e acompanhamento da audição em trabalhadores expostos a níveis de pressão sonora elevados. DOU, 22 de abril de 1998.
- 22 Fiorini AC, Parrado-Moran MES. Emissões otoacústicas produto de distorção: estudo de diferentes relações de níveis sonoros no teste em indivíduos com e sem perdas auditivas. Dist Comun 2005; 17 (3) 385-96