Appl Clin Inform 2017; 08(03): 936-944
DOI: 10.4338/ACI-2017-03-RA-0051
Research Article
Schattauer GmbH

Adaptation of Radiology Software to Improve Cardiology Results Reporting

Gregory Webster
1   Division of Cardiology, Ann and Robert H. Lurie Children’s Hospital of Chicago, Northwestern University Feinberg School of Medicine Chicago, US
,
Kendra Ward
1   Division of Cardiology, Ann and Robert H. Lurie Children’s Hospital of Chicago, Northwestern University Feinberg School of Medicine Chicago, US
,
Barbara J. Deal
1   Division of Cardiology, Ann and Robert H. Lurie Children’s Hospital of Chicago, Northwestern University Feinberg School of Medicine Chicago, US
,
Jeffrey B. Anderson
2   The Heart Institute Cincinnati Children‘s Hospital Medical Center Cincinnati, US
,
Sabrina Tsao
1   Division of Cardiology, Ann and Robert H. Lurie Children’s Hospital of Chicago, Northwestern University Feinberg School of Medicine Chicago, US
› Institutsangaben
Weitere Informationen

Publikationsverlauf

received: 28. März 2017

accepted in revised form: 01. Juli 2017

Publikationsdatum:
20. Dezember 2017 (online)

Summary

Objective: Twenty-four hour ambulatory electrocardiograms (“Holter” monitors) are a key diagnostic test in cardiology. Commercial electronic medical record (EMR) tools have not been designed for pediatric Holter monitor reporting and paper-based methods are inefficient.

Methods: Our tertiary pediatric hospital adapted a radiology EMR tool to a cardiology workflow in order to report Holter monitor results. A retrospective review was performed at 4 time points: prior to intervention, immediately post-intervention, at 6 months and at 12 months post-intervention. The primary outcome variable was time to reporting of Holter findings.

Results: Holter reports were reviewed on 527 studies (patient ages: 1 day to 42 years). The time between the date the patient returned the Holter monitor until the date the referring physician received a final report improved from 19.8 days to 1.5 days (p<0.001). This result was durable over the next 12 months of follow-up. Physician interpretation time improved from 2.1 days to 0.6 days (p=0.01). Transcriptionist time and result scanning time were eliminated (removing 1.9 days and 14 days from the workflow, respectively).

Conclusion: EMR systems are not typically designed for pediatric cardiology, but existing systems can be adapted, yielding important gains for patient care. In specialties like pediatric cardiology, there is insufficient volume nationally to drive development of commercial systems. This study demonstrates the general principle that creative adaptation of EMR systems can improve result reporting in pediatric cardiology and likely in other cardiology practices.

Citation: Webster G, Ward K, Deal BJ, Anderson JB, Tsao S. Adaptation of Radiology Software to Improve Cardiology Results Reporting. Appl Clin Inform 2017; 8: 936–944 https://doi.org/10.4338/ACI-2017-03-RA-0051

Human Subjects

No human subjects were involved in this project. Institutional Review Board approval was obtained prior to preparation of this manuscript for publication.


 
  • References

  • 1 Holter N, Glasscock W. Electrocardiographic Means. 1962 USA Patent 3215136,
  • 2 Warnes CA, Williams RG, Bashore TM, Child JS, Connolly HM, Dearani JA, del Nido P, Fasules JW, Graham Jr., TP, Hijazi ZM, Hunt SA, King ME, Landzberg MJ, Miner PD, Radford MJ, Walsh EP, Webb GD, Smith Jr., SC, Jacobs AK, Adams CD, Anderson JL, Antman EM, Buller CE, Creager MA, Ettinger SM, Halperin JL, Hunt SA, Krumholz HM, Kushner FG, Lytle BW, Nishimura RA, Page RL, Riegel B, Tarkington LG, Yancy CW. ACC/AHA 2008 guidelines for the management of adults with congenital heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Develop Guidelines on the Management of Adults With Congenital Heart Disease). Developed in Collaboration With the American Society of Echocardiography, Heart Rhythm Society, International Society for Adult Congenital Heart Disease, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic Surgeons. J Am Coll Cardiol 2008; 52 (Suppl. 23) e143-263.
  • 3 Khairy P, Aboulhosn J, Gurvitz MZ, Opotowsky AR, Mongeon FP, Kay J, Valente AM, Earing MG, Lui G, Gersony DR, Cook S, Ting JG, Nickolaus MJ, Webb G, Landzberg MJ, Broberg CS. Arrhythmia burden in adults with surgically repaired tetralogy of Fallot: a multi-institutional study. Circulation 2010; 122 (09) 868-875.
  • 4 Moak JP, Leifer ES, Tripodi D, Mohiddin SA, Fananapazir L. Long-term follow-up of children and adolescents diagnosed with hypertrophic cardiomyopathy: risk factors for adverse arrhythmic events. Pediatr Cardiol 2011; 32 (08) 1096-1105.
  • 5 Wackel P, Irving C, Webber S, Beerman L, Arora G. Risk stratification in Wolff-Parkinson-White syndrome: the correlation between noninvasive and invasive testing in pediatric patients. Pacing Clin Electro-physiol 2012; 35 (12) 1451-1457.
  • 6 Czosek RJ, Spar DS, Khoury PR, Anderson JB, Wilmot I, Knilans TK, Jefferies JL. Outcomes, arrhythmic burden and ambulatory monitoring of pediatric patients with left ventricular non-compaction and preserved left ventricular function. Am J Cardiol 2015; 115 (07) 962-966.
  • 7 Rhodes LA, Wernovsky G, Keane JF, Mayer Jr., JE, Shuren A, Dindy C, Colan SD, Walsh EP. Arrhythmias and intracardiac conduction after the arterial switch operation. J Thorac Cardiovasc Surg 1995; 109 (02) 303-310.
  • 8 Czosek RJ, Anderson J, Khoury PR, Knilans TK, Spar DS, Marino BS. Utility of ambulatory monitoring in patients with congenital heart disease. Am J Cardiol 2013; 111 (05) 723-730.
  • 9 Healthcare E. Epiphany Health Data. www.epiphanyhealthdata.com Accessed 8.13.15 2015.
  • 10 Schmiege P. Turnaround times. J Cardiovasc Manag 2005; 16: 12-3.