CC BY-NC-ND 4.0 · J Neuroanaesth Crit Care 2017; 04(02): 117-119
DOI: 10.4103/jnacc-jnacc-62.16
Case Report
Thieme Medical and Scientific Publishers Private Ltd.

A case of pneumothorax following bougie-guided intubation in a patient undergoing excision of an intraventricular space occupying lesion

Ramanan Rajagopal
1   Department of Anaesthesiology and Critical Care, Amrita Institute of Medical Sciences, Kochi, Kerala, India
,
Veena Jayaseelan
1   Department of Anaesthesiology and Critical Care, Amrita Institute of Medical Sciences, Kochi, Kerala, India
,
Mathew George
1   Department of Anaesthesiology and Critical Care, Amrita Institute of Medical Sciences, Kochi, Kerala, India
› Author Affiliations
Further Information

Publication History

Publication Date:
08 May 2018 (online)

Abstract

A 46-year-old female with intraventricular space occupying lesion was posted for craniotomy and excision of the same. Immediately following routine induction of general anaesthesia and a bougie-guided intubation, she developed increased airway pressures and desaturation associated with a decreased air entry on the right side of the chest suggestive of a right-sided pneumothorax which was confirmed with radio imaging and following the placement of chest drain the saturation improved and airway pressures decreased. To be faced with a pneumothorax following an intubation could be surprising for a non-suspecting anaesthesiologist and it can have important implications especially in neurosurgical cases where a tight control of intracranial pressure is warranted. Hence, this case report emphasises the need for a high index of clinical suspicion for proper management and safe patient outcome.

 
  • REFERENCES

  • 1 Martin LD, Mhyre JM, Shanks AM, Tremper KK, Kheterpal S. 3,423 emergency tracheal intubations at a university hospital: Airway outcomes and complications. Anesthesiology 2011; 114: 42-8
  • 2 de Almeida JP, Hajjar LA, Fukushima JT, Nakamura RE, Albertini R, Galas FR. Bronchial injury and pneumothorax after reintubation using an airway exchange catheter. Braz J Anesthesiol 2013; 63: 107-9
  • 3 Hensel M, Marnitz R. Pneumothorax following nasogastric feeding tube insertion: Case report and review of the literature. Anaesthesist 2010; 59: 229-32 234
  • 4 Zausig YA, Graf BM, Gust R. Occurrence of a pneumothorax secondary to malpositioned nasogastric tube: A case report. Minerva Anestesiol 2008; 74: 735-8
  • 5 Nunn C, Uffman J, Bhananker SM. Bilateral tension pneumothoraces following jet ventilation via an airway exchange catheter. J Anesth 2007; 21: 76-9
  • 6 Chen WY, Lin JA, Chen HL, Wong CS, Ho ST, Lu CC. Pneumothorax associated with tube exchanger-aided intubation following LMA-Fastrach placement in a patient during anesthesia induction. Acta Anaesthesiol Taiwan 2004; 42: 227-31
  • 7 Sucato DJ, Girgis M. Bilateral pneumothoraces, pneumomediastinum, pneumoperitoneum, pneumoret roperitoneum, and subcutaneous emphysema following intubation with a double-lumen endotracheal tube for thoracoscopic anterior spinal release and fusion in a patient with idiopathic scoliosis. J Spinal Disord Tech 2002; 15: 133-8
  • 8 Biswas C, Jana N, Maitra S. Bilateral pneumothorax following tracheal intubation. Br J Anaesth 1989; 62: 338-9
  • 9 Chen EH, Logman ZM, Glass PS, Bilfinger TV. A case of tracheal injury after emergent endotracheal intubation: A review of the literature and causalities. Anesth Analg 2001; 93: 1270-1
  • 10 Ludwig HC, Klingler M, Timmermann A, Weyland W, Mursch K, Reparon C. et al. The influence of airway pressure changes on intracranial pressure (ICP) and the blood flow velocity in the middle cerebral artery (VMCA). Anasthesiol Intensivmed Notfallmed Schmerzther 2000; 35: 141-5
  • 11 Berg LF, Mafee MF, Campos M, Applebaum EL. Mechanisms of pneumothorax following tracheal intubation. Ann Otol Rhinol Laryngol 1988; 97: 500-5
  • 12 Zlotnik A, Gruenbaum SE, Gruenbaum BF, Dubilet M, Cherniavsky E. Iatrogenic tracheobronchial rupture: A case report and review of the literature. Int J Case Rep Images 2011; 2: 12-6